Is cerebral microembolism in mechanical prosthetic heart valves clinically relevant?

被引:20
作者
Nadareishvili, ZG
Beletsky, V
Black, SE
Fremes, SE
Freedman, M
Kurzman, D
Leach, L
Norris, JW
机构
[1] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Stroke Res Unit, Toronto, ON, Canada
[2] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Div Neurol, Toronto, ON, Canada
[3] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Div Cardiovasc Surg, Toronto, ON, Canada
[4] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Div Psychol, Toronto, ON, Canada
关键词
embolism; ultrasonography; Doppler; transcranial; prosthetic heart valves;
D O I
10.1111/j.1552-6569.2002.tb00138.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose. High-intensity transient signals (HITS) are frequently detected by transcranial Doppler (TCD) ultrasound in patients with mechanical prosthetic heart valves (PHVs), but published data about their clinical relevance are controversial. This study was undertaken to determine the clinical relevance of HITS in patients with mechanical PHVs Methods. The authors prospectively studied patients with mechanical PHVs using TCD monitoring for microemboli detection with and without 0, inhalation. The cognitive testing of patients included the Mini-Mental State Examination, the Dementia Rating Scale, and MicroCog. Results. The authors studied 36 patients (20 women, aged 58 13 years). HITS were detected in 72% of patients, with a nonsignificant increase of HITS rate in the aortic valve group (P=.07). There was no significant difference in HITS rate between asymptomatic and symptomatic patients. In a multiple linear regression model, HITS rate was predicted only by younger age (P=.024). No correlation was found between HITS rate and the cognitive performance of patients. There was a significant decrease in HITS rate after 100% O-2 inhalation compared to baseline levels (32 8+/-40.2 vs 6.1 +/- 11.3, P = .011). Subgroup analysis in asymptomatic patients confirmed this finding (P = .017), but in symptomatic patients, decreased HITS rate was not statistically significant (P = .18). Conclusion. Only age was a significant predictor of HITS in patients with mechanical PHVs. The lack of association between HITS, clinical symptoms, and cognitive functioning suggests that most of these signals represent harmless epiphenomena, and only HITS detected after O-2 inhalation have any clinical relevance.
引用
收藏
页码:310 / 315
页数:6
相关论文
共 21 条
[1]  
BRAEKKEN SK, 1995, STROKE, V26, P1225
[2]   OPTIMAL ORAL ANTICOAGULANT-THERAPY IN PATIENTS WITH MECHANICAL HEART-VALVES [J].
CANNEGIETER, SC ;
ROSENDAAL, FR ;
WINTZEN, AR ;
VANDERMEER, FJM ;
VANDENBROUCKE, JP ;
BRIET, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (01) :11-17
[3]   Microemboli in cerebral circulation and alteration of cognitive abilities in patients with mechanical prosthetic heart valves [J].
Deklunder, G ;
Roussel, M ;
Lecroart, JL ;
Prat, A ;
Gautier, C .
STROKE, 1998, 29 (09) :1821-1826
[4]   Oxygen inhalation can differentiate gaseous from nongaseous microemboli detected by transcranial Doppler ultrasound [J].
Droste, DW ;
Hansberg, T ;
Kemeny, V ;
Hammel, D ;
SchulteAltedorneburg, G ;
Nabavi, DG ;
Kaps, M ;
Scheld, HH ;
Ringelstein, EB .
STROKE, 1997, 28 (12) :2453-2456
[5]   MINI-MENTAL STATE - PRACTICAL METHOD FOR GRADING COGNITIVE STATE OF PATIENTS FOR CLINICIAN [J].
FOLSTEIN, MF ;
FOLSTEIN, SE ;
MCHUGH, PR .
JOURNAL OF PSYCHIATRIC RESEARCH, 1975, 12 (03) :189-198
[6]   PREVALENCE AND CHARACTERISTICS OF INTRACRANIAL MICROEMBOLI SIGNALS IN PATIENTS WITH DIFFERENT TYPES OF PROSTHETIC CARDIAC VALVES [J].
GEORGIADIS, D ;
GROSSET, DG ;
KELMAN, A ;
FAICHNEY, A ;
LEES, KR .
STROKE, 1994, 25 (03) :587-592
[7]  
Georgiadis D., 1994, European Heart Journal, V15, P64
[8]   Influence of oxygen ventilation on Doppler microemboli signals in patients with artificial heart valves [J].
Georgiadis, D ;
Wenzel, A ;
Lehmann, D ;
Lindner, A ;
Zerkowski, HR ;
Zierz, S ;
Spencer, MP .
STROKE, 1997, 28 (11) :2189-2194
[9]   Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid [J].
Kaps, M ;
Hansen, J ;
Weiher, M ;
Tiffert, K ;
Kayser, I ;
Droste, DW .
STROKE, 1997, 28 (02) :322-325
[10]  
Mattis S., 1988, DEMENTIA RATING SCAL