Effect of the presence of orthodontic brackets on intraoral scans

被引:22
作者
Kang, Sung-Ja [1 ]
Kee, Youn-Ju [1 ]
Lee, Kyungmin Clara [1 ]
机构
[1] Chonnam Natl Univ, Sch Dent, Dept Orthodont, 33 Yongbong Ro, Gwangju 61186, South Korea
基金
新加坡国家研究基金会;
关键词
Intraoral scan; Orthodontic brackets; Accuracy; Image noise; ROOT POSITION SETUP; ACCURACY; RELIABILITY; SCANNERS; IMPRESSIONS; INDEX;
D O I
10.2319/040420-254.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The need for intraoral scanning in the presence of brackets has increased for monitoring tooth movement during orthodontic treatment. The purpose of this study was to evaluate the effect of orthodontic brackets bonded to tooth surfaces on intraoral scans. Materials and Methods: Intraoral scans were performed in 30 patients using both iTero and Trios scanners before and after bonding of the brackets. The two sets of intraoral scans of each patient and intraoral scans with and without brackets were superimposed using a best-fit algorithm, and three-dimensional (3D) surface analysis was performed. In each superimposition, discrepancies in the 3D axes and arch-width measurements in the incisor and molar regions were compared. In addition, the range of distortion around the brackets was evaluated on the cross sections of each superimposition. Results: The overall discrepancies between the intraoral scans with and without brackets were within 0.30 mm. The arch-width discrepancies in the molar region were greater than those in the incisor region, but the differences were not statistically significant (P = .972 for iTero; P = .960 for Trios). The cross sections of the superimposed intraoral scans with and without brackets showed that the deviations were within 0.40 mm in the horizontal section and within 0.35 mm in the vertical section around the brackets. Conclusions: The results of this study indicate that the accuracy of intraoral scans, even in the presence of brackets, is clinically acceptable, and the regions beyond 0.50 mm around the brackets should be used for superimposition on images without brackets.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 22 条
[1]   Learning curve of intraoral scanning by prosthodontic residents [J].
Al Hamad, Khaled Q. .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02) :277-283
[2]   Radiographic technique and brackets affect measurements of proximal enamel thickness on mandibular incisors [J].
Ang, Amy Giok Phing ;
Steegmans, Pauline Antoinette Josephine ;
Kerdijk, Wouter ;
Livas, Christos ;
Ren, Yijin .
EUROPEAN JOURNAL OF ORTHODONTICS, 2017, 39 (01) :25-30
[3]   Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review [J].
Aragon, Monica L. C. ;
Pontes, Luana F. ;
Bichara, Livia M. ;
Flores-Mir, Carlos ;
Normando, David .
EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (04) :429-434
[4]   THE DEVELOPMENT OF AN INDEX OF ORTHODONTIC TREATMENT PRIORITY [J].
BROOK, PH ;
SHAW, WC .
EUROPEAN JOURNAL OF ORTHODONTICS, 1989, 11 (03) :309-320
[5]  
Chochlidakis KM, 2016, J PROSTHET DENT, V116, P184, DOI 10.1016/j.prosdent.2015.12.017
[6]   Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence [J].
Goracci, Cecilia ;
Franchi, Lorenzo ;
Vichi, Alessandro ;
Ferrari, Marco .
EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (04) :422-428
[7]  
Hack G., 2015, ADA PROFESSIONAL PRO, V10, P1
[8]   Complete 3-D reconstruction of dental cast shape using perceptual grouping [J].
Hirogaki, Y ;
Sohmura, T ;
Satoh, H ;
Takahashi, J ;
Takada, K .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (10) :1093-1101
[9]  
Jung YR, 2016, INT J COMPUT DENT, V19, P203
[10]   Accuracy and reliability of the expected root position setup on clinical decision making of root position at midtreatment [J].
Lee, Robert J. ;
Ko, Jaemin ;
Park, Justyn ;
Pi, Sarah ;
Devgon, Denise ;
Nelson, Gerald ;
Hatcher, David ;
Oberoi, Snehlata .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (04) :566-573