Dual-Energy CT Angiography in Peripheral Arterial Occlusive Disease

被引:88
作者
Brockmann, Carolin [1 ]
Jochum, Susanne [1 ]
Sadick, Maliha [1 ]
Huck, Kurt [2 ]
Ziegler, Peter [3 ]
Fink, Christian [1 ]
Schoenberg, Stefan O. [1 ]
Diehl, Steffen J. [1 ]
机构
[1] Univ Heidelberg, Dept Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] Univ Heidelberg, Med Fac Mannheim, Med Clin 1, D-68167 Mannheim, Germany
[3] Univ Heidelberg, Dept Surg, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
Dual-energy CT angiography; Bone removal; Pelvis; Lower extremities; Peripheral arterial disease; DIGITAL-SUBTRACTION-ANGIOGRAPHY; ENHANCED MR-ANGIOGRAPHY; INITIAL-EXPERIENCE; LOWER-EXTREMITIES; METAANALYSIS; AORTA; DSA;
D O I
10.1007/s00270-008-9491-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to study the accuracy of dual-energy computed tomographic angiography (DE-CTA) for the assessment of symptomatic peripheral arterial occlusive disease of the lower extremity by using the dual-energy bone removal technique compared with a commercially available conventional bone removal tool. Twenty patients underwent selective digital subtraction angiography and DE-CTA of the pelvis and lower extremities. CTA data were postprocessed with two different applications: conventional bone removal and dual-energy bone removal. All data were reconstructed and evaluated as 3D maximum-intensity projections. Time requirements for reconstruction were documented. Sensitivity, specificity, accuracy, and concordance of DE-CTA regarding degree of stenosis and vessel wall calcification were calculated. A total of 359 vascular segments were analyzed. Compared with digital subtraction angiography, sensitivity, specificity, and accuracy, respectively, of CTA was 97.2%, 94.1%, and 94.7% by the dual-energy bone removal technique. The conventional bone removal tool delivered a sensitivity of 77.1%, a specificity of 70.7%, and an accuracy of 72.0%. Best results for both postprocessing methods were achieved in the vascular segments of the upper leg. In severely calcified segments, sensitivity, specificity, and accuracy stayed above 90% by the dual-energy bone removal technique, whereas the conventional bone removal technique showed a substantial decrease of sensitivity, specificity, and accuracy. DE-CTA is a feasible and accurate diagnostic method in the assessment of symptomatic peripheral arterial occlusive disease. Results obtained by DE-CTA are superior to the conventional bone removal technique and less dependent on vessel wall calcifications.
引用
收藏
页码:630 / 637
页数:8
相关论文
共 17 条
[1]  
Bui Trung D, 2005, Vasc Endovascular Surg, V39, P481, DOI 10.1177/153857440503900604
[2]   Infrarenal aortic and lower-extremity arterial disease: Diagnostic performance of multi-detector row CT angiography [J].
Catalano, C ;
Fraioli, F ;
Laghi, A ;
Napoli, A ;
Bezzi, M ;
Pediconi, F ;
Danti, M ;
Nofroni, I ;
Passariello, R .
RADIOLOGY, 2004, 231 (02) :555-563
[3]   Dual-Energy CT Angiography of the Lung in Patients with Suspected Pulmonary Embolism: Initial Results [J].
Fink, C. ;
Johnson, T. R. ;
Michaely, H. J. ;
Morhard, D. ;
Becker, C. ;
Reiser, M. ;
Nikolaou, K. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (10) :879-883
[4]  
FONTAINE R, 1954, Helv Chir Acta, V21, P499
[5]   Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA [J].
Fraioli, F ;
Catalano, C ;
Napoli, A ;
Francone, M ;
Venditti, F ;
Danti, M ;
Pediconi, F ;
Passariello, R .
EUROPEAN RADIOLOGY, 2006, 16 (01) :137-146
[6]   Lower extremity arterial disease: Multidetector CT angiography - Meta-analysis [J].
Heijenbrok-Kal, Majanka H. ;
Kock, Marc C. J. M. ;
Hunink, M. G. Myriam .
RADIOLOGY, 2007, 245 (02) :433-439
[7]  
Heuschmid M, 2003, EUR J MED RES, V8, P389
[8]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[9]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415
[10]   Multidetector CT angiography of the aortoiliac system and lower extremities: A prospective comparison with digital subtraction angiography [J].
Martin, ML ;
Tay, KH ;
Flak, B ;
Fry, PD ;
Doyle, DL ;
Taylor, DC ;
Hsiang, YN ;
Machan, LS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (04) :1085-1091