A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments

被引:11
作者
Machida, Haruhiko [1 ]
Fukui, Rika [1 ]
Tanaka, Isao [1 ]
Shen, Yun [1 ]
Ishikawa, Takuya [1 ]
Tate, Etsuko [1 ]
Suzuki, Shigeru [2 ]
Ueno, Eiko [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Radiol, Med Ctr East, Arakawa Ku, Tokyo 1168567, Japan
[2] Saitama Red Cross Hosp, Dept Diagnost Radiol, Chuo Ku, Saitama 3380001, Japan
关键词
Computed tomography; Gemstone spectral imaging; Image noise; Iterative reconstruction; Radiation dosage; FILTERED BACK-PROJECTION; DUAL-ENERGY CT; DOSE REDUCTION; QUALITY;
D O I
10.1007/s11604-014-0288-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate a method for selecting a protocol for body CT scan to acquire monochromatic images (MIs) by gemstone spectral imaging (GSI) with or without adaptive statistical iterative reconstruction (ASiR). We subjected a phantom to conventional scanning at 120 kVp and 50-700 mAs and GSI at 165-600 mAs; reconstructed MIs at 65 keV with ASiR 0-100 % for GSI; placed 5 regions of interest on each of 3 consecutive reconstructed slices to obtain the averaged standard deviation (SD) as image noise for conventional scan and GSI. Linear regression analysis yielded the mAs by conventional scan that could be used to achieve similar image noise by GSI. To achieve similar noise, we found excellent linear correlation of mAs between GSI with ASiR 0-100 % and conventional scan (r = 1.00, P < 0.0001), and obtained a table of equivalent mAs between MIs at 65 keV and conventional CT at 120 kVp. We can select a protocol for body CT scan for MIs at 65 keV with or without ASiR with results comparable to those of conventional CT at 120 kVp.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 16 条
[1]  
Blake MA, 2011, RADIOGRAPHICS, V31, P1047, DOI 10.1148/rg.314105159
[2]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[3]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[4]   Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure Control [J].
Kalra, Mannudeep K. ;
Naz, Nausheen ;
Rizzo, Stefania M. R. ;
Blake, Michael A. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2005, 34 (05) :171-181
[5]   Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software [J].
Lee, Young Han ;
Park, Kwan Kyu ;
Song, Ho-Taek ;
Kim, Sungjun ;
Suh, Jin-Suck .
EUROPEAN RADIOLOGY, 2012, 22 (06) :1331-1340
[6]   A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction [J].
Leipsic, Jonathon ;
Nguyen, Giang ;
Brown, Jaqueline ;
Sin, Don ;
Mayo, John R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :1095-1099
[7]   Quantification of head and body CTDIVOL of dual-energy x-ray CT with fast-kVp switching [J].
Li, Baojun ;
Yadava, Girijesh ;
Hsieh, Jiang .
MEDICAL PHYSICS, 2011, 38 (05) :2595-2601
[8]   Spectral CT in patients with small HCC: investigation of image quality and diagnostic accuracy [J].
Lv, Peijie ;
Lin, Xiao Zhu ;
Chen, Kemin ;
Gao, Jianbo .
EUROPEAN RADIOLOGY, 2012, 22 (10) :2117-2124
[9]   Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Improved Image Quality as Compared with That Obtained with Conventional 120-kVp CT [J].
Matsumoto, Kazuhiro ;
Jinzaki, Masahiro ;
Tanami, Yutaka ;
Ueno, Akihisa ;
Yamada, Minoru ;
Kuribayashi, Sachio .
RADIOLOGY, 2011, 259 (01) :257-262
[10]   Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: Optimization of energy level viewing significantly increases lesion contrast [J].
Patel, B. N. ;
Thomas, J. V. ;
Lockhart, M. E. ;
Berland, L. L. ;
Morgan, D. E. .
CLINICAL RADIOLOGY, 2013, 68 (02) :148-154