Post-dilatation after implantation of bioresorbable everolimus- and novolimus-eluting scaffolds: an observational optical coherence tomography study of acute mechanical effects

被引:7
作者
Blachutzik, Florian [1 ]
Boeder, Niklas [2 ]
Wiebe, Jens [3 ]
Mattesini, Alessio [4 ]
Doerr, Oliver [2 ]
Most, Astrid [2 ]
Bauer, Timm [2 ]
Roether, Jens [1 ]
Troebs, Monique [1 ]
Schlundt, Christian [1 ]
Achenbach, Stephan [1 ]
Hamm, Christian W. [2 ]
Nef, Holger M. [2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Dept Cardiol, Erlangen, Germany
[2] Univ Giessen, Dept Cardiol & Angiol, Giessen, Germany
[3] Tech Univ Munich, Deutsch Herzzentrum Munchen, Munich, Germany
[4] Azienda Osped Univ Careggi, Dept Heart & Vessels, Florence, Italy
关键词
Bioresorbable vascular scaffolds; Coronary artery disease; Optical coherence tomography; Percutaneous coronary intervention (PCI); INTRAVASCULAR ULTRASOUND ANALYSIS; STENT THROMBOSIS; VASCULAR SCAFFOLD; FOLLOW-UP; IN-VIVO; IMPACT; ABSORB; DEPLOYMENT; 2ND-GENERATION; INTERVENTION;
D O I
10.1007/s00392-016-1048-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective was to investigate the acute mechanical effects of post-dilatation on bioresorbable scaffolds (BRS) as determined by optical coherence tomography (OCT). Post-dilatation with high-pressure balloons is regarded as a key component of BRS implantation for treatment of coronary artery stenoses. However, the impact of post-dilatation on BRS in vivo has not been thoroughly investigated. OCT was performed after the implantation procedure of 51 everolimus-eluting or novolimus-eluting polylactic acid-based BRS with (n = 27) or without non-compliant balloon post-dilatation (n = 24). The number of malapposed struts, strut fractures, edge dissections, residual in-scaffold area stenosis, and incomplete scaffold apposition area was analyzed over the complete length of each BRS with a spacing of 1 mm. OCT revealed a significantly lower incomplete scaffold apposition area if post-dilatation was performed (0.16 +/- 0.49 mm(2) with post-dilatation vs. 2.65 +/- 2.78 mm(2) without post-dilatation, p < 0.001), as well as a significantly lower absolute number of malapposed struts (1 +/- 2 with post-dilatation vs. 13 +/- 13 without post-dilatation, p < 0.001). No significant differences regarding residual in-scaffold area stenosis, strut fracture, edge dissection, symmetry index, or eccentricity index were observed in patients with vs. without post-dilatation. Post-dilatation of BRS with non-compliant balloons significantly reduces the number of malapposed struts and incomplete scaffold apposition area without inducing higher rates of edge dissection or strut fracture.
引用
收藏
页码:271 / 279
页数:9
相关论文
共 28 条
[21]   Impact of final Stent dimensions on long-term results following sirolimus-eluting stent implantation - Serial intravascular ultrasound analysis from the SIRIUS trial [J].
Sonoda, S ;
Morino, Y ;
Ako, J ;
Terashima, M ;
Hassan, AHM ;
Bonneau, HN ;
Leon, MB ;
Moses, JW ;
Yock, PG ;
Honda, Y ;
Kuntz, RE ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :1959-1963
[22]   Mechanisms of stent thrombosis analysed by optical coherence tomography: insights from the national PESTO French registry [J].
Souteyrand, Geraud ;
Amabile, Nicolas ;
Mangin, Lionel ;
Chabin, Xavier ;
Meneveau, Nicolas ;
Cayla, Guillaume ;
Vanzetto, Gerald ;
Barnay, Pierre ;
Trouillet, Charlotte ;
Rioufol, Gilles ;
Range, Gregoire ;
Teiger, Emmanuel ;
Delaunay, Regis ;
Dubreuil, Olivier ;
Lhermusier, Thibault ;
Mulliez, Aurelien ;
Levesque, Sebastien ;
Belle, Loic ;
Caussin, Christophe ;
Motreff, Pascal .
EUROPEAN HEART JOURNAL, 2016, 37 (15) :1208-U120
[23]   The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial [J].
Suwannasom, Pannipa ;
Sotomi, Yohei ;
Ishibashi, Yuki ;
Cavalcante, Rafael ;
Albuquerque, Felipe N. ;
Macaya, Carlos ;
Ormiston, John A. ;
Hill, Jonathan ;
Lang, Irene M. ;
Egred, Mohaned ;
Fajadet, Jean ;
Lesiak, Maciej ;
Tijssen, Jan G. ;
Wykrzykowska, Joanna J. ;
de Winter, Robbert J. ;
Chevalier, Bernard ;
Serruys, Patrick W. ;
Onuma, Yoshinobu .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (12) :1231-1242
[24]  
Tamburino C, 2015, EUROINTERVENTION, V11, P45, DOI 10.4244/EIJV11SVA41
[25]   Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography [J].
Taniwaki, Masanori ;
Radu, Maria D. ;
Zaugg, Serge ;
Amabile, Nicolas ;
Garcia-Garcia, Hector M. ;
Yamaji, Kyohei ;
Jorgensen, Erik ;
Kelbaek, Henning ;
Pilgrim, Thomas ;
Caussin, Christophe ;
Zanchin, Thomas ;
Veugeois, Aurelie ;
Abildgaard, Ulrik ;
Jueni, Peter ;
Cook, Stephane ;
Koskinas, Konstantinos C. ;
Windecker, Stephan ;
Raeber, Lorenz .
CIRCULATION, 2016, 133 (07) :650-660
[26]   Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies A Report From the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation [J].
Tearney, Guillermo J. ;
Regar, Evelyn ;
Akasaka, Takashi ;
Adriaenssens, Tom ;
Barlis, Peter ;
Bezerra, Hiram G. ;
Bouma, Brett ;
Bruining, Nico ;
Cho, Jin-man ;
Chowdhary, Saqib ;
Costa, Marco A. ;
de Silva, Ranil ;
Dijkstra, Jouke ;
Di Mario, Carlo ;
Dudeck, Darius ;
Falk, Erlin ;
Feldman, Marc D. ;
Fitzgerald, Peter ;
Garcia, Hector ;
Gonzalo, Nieves ;
Granada, Juan F. ;
Guagliumi, Giulio ;
Holm, Niels R. ;
Honda, Yasuhiro ;
Ikeno, Fumiaki ;
Kawasaki, Masanori ;
Kochman, Janusz ;
Koltowski, Lukasz ;
Kubo, Takashi ;
Kume, Teruyoshi ;
Kyono, Hiroyuki ;
Lam, Cheung Chi Simon ;
Lamouche, Guy ;
Lee, David P. ;
Leon, Martin B. ;
Maehara, Akiko ;
Manfrini, Olivia ;
Mintz, Gary S. ;
Mizuno, Kyiouchi ;
Morel, Marie-angele ;
Nadkarni, Seemantini ;
Okura, Hiroyuki ;
Otake, Hiromasa ;
Pietrasik, Arkadiusz ;
Prati, Francesco ;
Raeber, Lorenz ;
Radu, Maria D. ;
Rieber, Johannes ;
Riga, Maria ;
Rollins, Andrew .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (12) :1058-1072
[27]   Predictors and outcomes of stent thrombosis - An intravascular ultrasound registry [J].
Uren, NG ;
Schwarzacher, SP ;
Metz, JA ;
Lee, DR ;
Honda, Y ;
Yeung, AC ;
Fitzgerald, PJ ;
Yock, PG .
EUROPEAN HEART JOURNAL, 2002, 23 (02) :124-132
[28]   Long-Term Clinical Outcome After a First Angiographically Confirmed Coronary Stent Thrombosis An Analysis of 431 Cases [J].
van Werkum, Jochem W. ;
Heestermans, Antonius A. C. M. ;
de Korte, Fleur I. ;
Kelder, Johannes C. ;
Suttorp, Maarten-Jan ;
Rensing, Benno J. W. M. ;
Zwart, Bastiaan ;
Brueren, B. R. Guus ;
Koolen, Jacques J. ;
Dambrink, Jan-Henk E. ;
van't Hof, Arnoud W. J. ;
Verheugt, Freek W. A. ;
ten Berg, Jurrien M. .
CIRCULATION, 2009, 119 (06) :828-834