Characterisation of ventilation rate in naturally-ventilated buildings using heat dissipation from a line source

被引:1
作者
Lule, Ivan [1 ]
Ozcan, Sezin Eren [1 ]
Berckmans, Daniel [1 ]
机构
[1] Katholieke Univ Leuven, BIORES Measure Model & Manage Bioresponses M3, B-3001 Heverlee, Belgium
关键词
Data-based mechanistic approach; Heat dissipation; Natural ventilation; Ventilation rate; Well-mixed zones; MASS-TRANSFER; FLOW; AIR; BUOYANCY; PERFORMANCE; ENERGY; WIND; ZONE;
D O I
10.1016/j.biosystemseng.2014.05.009
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
To determine air exchange in naturally-ventilated buildings, Eren Ozcan, Vranken, and Berckmans (2009) used heat dissipation from a heat source close to an inlet to measure ventilation rate through the opening. Because their method used a bulky heat source, which caused an obstruction to airflow, they were unable to cover the whole of the inlet opening, and therefore, an improved technique was required. This study extended the earlier method to investigate heat dissipation by using a line heat source that covered the whole vertical extent of the inlet. Steady state experiments were performed with a constant heat source, and dynamic experiments, where the heat source was turned off during the ventilation process. A two-dimensional temperature distribution around the ventilation opening was obtained by infrared thermal imaging. Using data-based mechanistic approach, well-mixed temperature zones were used to predict the volumetric concentration of fresh air supply, and to investigate the effect of buoyancy on the heat plume. Results obtained revealed that ventilation rate can be predicted using data-based mechanistic approach with an error of 8%. (c) 2014 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 32 条
[1]   Airflow rates by combined natural ventilation with opposing wind-unambiguous solutions for practical use [J].
Andersen, Karl Terpager .
BUILDING AND ENVIRONMENT, 2007, 42 (02) :534-542
[2]   Theory for natural ventilation by thermal buoyancy in one zone with uniform temperature [J].
Andersen, KT .
BUILDING AND ENVIRONMENT, 2003, 38 (11) :1281-1289
[3]  
[Anonymous], 1996, 688 NBN NI
[4]  
[Anonymous], 2001, HDB FUNDAMENTALS
[5]  
ASTM, 2000, ASTM E741-00
[6]   Measuring flow velocity at elevated temperature with a hot wire anemometer calibrated in cold flow [J].
Benjamin, SF ;
Roberts, CA .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (04) :703-706
[7]   Ventilation performance measurement using constant concentration dosing strategy [J].
Chao, CY ;
Wan, MP ;
Law, AK .
BUILDING AND ENVIRONMENT, 2004, 39 (11) :1277-1288
[8]   Buoyancy-driven displacement natural ventilation in a single-zone building with three-level openings [J].
Chen, ZD ;
Li, YG .
BUILDING AND ENVIRONMENT, 2002, 37 (03) :295-303
[9]   On the combination of air velocity and flow measurements in single sided natural ventilation configurations [J].
Dascalaki, E ;
Santamouris, M ;
Argiriou, A ;
Helmis, C ;
Asimakopoulos, DN ;
Papadopoulos, K ;
Soilemes, A .
ENERGY AND BUILDINGS, 1996, 24 (02) :155-165
[10]   Behaviour of well-mixed zones (WMZs) in an imperfectly mixed ventilated room [J].
Desta, T. Zerihun ;
Baelmans, M. ;
Berckmans, D. .
BUILDING AND ENVIRONMENT, 2008, 43 (12) :2035-2045