Investigation of the Power Quality Concerns of Input Current in Single-Phase Frequency Step-Down Converter

被引:5
作者
Ashraf, Naveed [1 ]
Abbas, Ghulam [1 ]
Ullah, Nasim [2 ]
Al-Ahmadi, Ahmad Aziz [2 ]
Raza, Ali [3 ]
Farooq, Umar [4 ]
Jamil, Mohsin [5 ]
机构
[1] Univ Lahore, Dept Elect Engn, Lahore 54000, Pakistan
[2] Taif Univ, Coll Engn, Dept Elect Engn, At Taif 21944, Saudi Arabia
[3] Univ Engn & Technol, Dept Elect Engn, Lahore 54000, Pakistan
[4] Univ Punjab, Dept Elect Engn, Lahore 54590, Pakistan
[5] Mem Univ Newfoundland, Fac Engn & Appl Sci, Dept Elect & Comp Engn, St John, NF A1B 3X5, Canada
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 07期
关键词
multistage converters; frequency converters; electromagnetic interference; cycloconverter; power quality; harmonic factor; AC-AC CONVERTERS;
D O I
10.3390/app12073663
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Single-phase direct frequency converters are gaining attraction at the research and academic level as they are rapidly getting space over conventional multistage converters. The converters developed with a rectification and inversion process using a DC-link level are examples of multistage converters with some serious concerns such as an increase in the overall weight, losses, and cost. They also suffer from the low-reliability issue due to the issues involved with DC-link capacitors and problems linked with electromagnetic interference (EMI) caused by high-frequency pulse width modulation (PWM) switching. These problems are addressed with line frequency switching cycloconverters. In these converters, the power quality of the output voltage is improved by governing the amplitude of some selected output pulses or half-cycles. For this purpose, a low-frequency multiple tapping transformer may be used to obtain various voltage levels. However, its use is the main source of increased overall weight, losses, cost, and volume. In transformer eliminated topologies, high-frequency PWM control can be employed to control the magnitude of some selected half cycles of the output voltage. However, this approach may arise some problems related to EMI. In both control techniques, the attention is focused on the power quality of the output voltage only. The concern for the input current is ignored and not yet analyzed. This is one of the critical power quality concerns and requires further investigation. The magnitude control of the output half-cycles causes the variation in the amplitude of some half cycles of the input currents. As a result, all half cycles of the input current become non-symmetric. It generates harmonics that are always of low frequency and cannot be easily filtered out. It results in a high value of the harmonic factor (HF) of the input current. The improvement in the power quality of the output voltages severally degrades the power quality of the input currents. In this research, this problem is investigated with mathematically computed harmonic coefficients with a pulse selective approach. Also, a simple single-phase cycloconverter is introduced to improve the power quality index of the input current. The overall analysis is supported by the results obtained from a Simulink-based environment and a practically constructed prototype.
引用
收藏
页数:18
相关论文
共 22 条
[1]   A New Class of Single-Phase High-Frequency Isolated Z-Source AC-AC Converters With Reduced Passive Components [J].
Ahmed, Hafiz Furqan ;
Cha, Honnyong .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (02) :1410-1419
[2]   A Single-Phase Buck-Boost Matrix Converter With Only Six Switches and Without Commutation Problem [J].
Ahmed, Hafiz Furqan ;
Cha, Honnyong ;
Khan, Ashraf Ali ;
Kim, Juyong ;
Cho, Jintae .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (02) :1232-1244
[3]   A Transformerless AC-AC Converter with Improved Power Quality Employed to Step-Down Power Frequency at Output [J].
Ashraf, Naveed ;
Abbas, Ghulam ;
Ullah, Nasim ;
Al-Ahmadi, Ahmad Aziz ;
Yasin, Abdul Rehman ;
Awan, Ahmed Bilal ;
Jamil, Mohsin .
ENERGIES, 2022, 15 (02)
[4]   A Simple Two-Stage AC-AC Circuit Topology Employed as High-Frequency Controller for Domestic Induction Heating System [J].
Ashraf, Naveed ;
Abbas, Ghulam ;
Ullah, Nasim ;
Alahmadi, Ahmad Aziz ;
Awan, Ahmed Bilal ;
Zubair, Muhammad ;
Farooq, Umar .
APPLIED SCIENCES-BASEL, 2021, 11 (18)
[5]   Power Quality Analysis of the Output Voltage of AC Voltage and Frequency Controllers Realized with Various Voltage Control Techniques [J].
Ashraf, Naveed ;
Abbas, Ghulam ;
Abbassi, Rabeh ;
Jerbi, Houssem .
APPLIED SCIENCES-BASEL, 2021, 11 (02) :1-24
[6]   A New Single-Phase Direct Frequency Controller Having Reduced Switching Count without Zero-Crossing Detector for Induction Heating System [J].
Ashraf, Naveed ;
Izhar, Tahir ;
Abbas, Ghulam ;
Awan, Ahmed Bilal ;
Alghamdi, Ali S. ;
Abo-Khalil, Ahmed G. ;
Sayed, Khairy ;
Farooq, Umar ;
Balas, Valentina E. .
ELECTRONICS, 2020, 9 (03)
[7]   A Single-Phase Buck and Boost AC-to-AC Converter with Bipolar Voltage Gain: Analysis, Design, and Implementation [J].
Ashraf, Naveed ;
Izhar, Tahir ;
Abbas, Ghulam ;
Balas, Valentina E. ;
Balas, Marius M. ;
Lin, Tsung-Chih ;
Asad, Muhammad Usman ;
Farooq, Umar ;
Gu, Jason .
ENERGIES, 2019, 12 (07)
[8]   Modeling and Evaluation of Cycloconverter-Fed Two-Stator-Winding SAG Mill Drive-Part I: Modeling Options [J].
Castro Palavicino, Pablo ;
Anibal Valenzuela, M. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (03) :2574-2581
[9]   Development of a DC-Side Direct Current Controlled Active Ripple Filter for Eliminating the Double-Line-Frequency Current Ripple in a Single-Phase DC/AC Conversion System [J].
Chen, Ying-Chieh ;
Chen, Liang-Rui ;
Lai, Ching-Ming ;
Lin, Yuan-Chih ;
Kuo, Ting-Jung .
ENERGIES, 2020, 13 (18)
[10]   Single-Phase Safe-Commutation Trans-Z-Source AC-AC Converter With Continuous Input Current [J].
He, Liangzong ;
Nai, Jixiao ;
Zhang, Jianhuan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (06) :5135-5145