Performance of gas tankless (instantaneous) water heaters under various international standards

被引:14
作者
Bourke, Grant [1 ]
Bansal, Pradeep [1 ]
Raine, Robert [1 ]
机构
[1] Univ Auckland, Dept Mech Engn, Auckland 1, New Zealand
关键词
Water heater; Gas instantaneous; Tankless; AS4552; EN13203; CFR430; HOT-WATER; SOLAR; EFFICIENCY; BOILER;
D O I
10.1016/j.apenergy.2014.06.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a novel review and laboratory test results of four standard test methods for determining the energy consumption of microprocessor controlled gas tankless water heaters. The test standards examined are from Australia, Europe, Japan and North America. The European test standard is found to be technically the most comprehensive in measuring all aspects of energy consumption for these types of appliances. Four water heaters, both conventional and condensing type, ranging in capacity from 28 to 55 kW are tested to each of the test standards. The European and North American tests deliver similar results. Those to the Australian standard yield higher energy use while the Japanese method produces the lowest consumption. The relative difference in energy use between water heater models tested to any single standard is consistent, with the exception that the Australian test appears to favour the smaller water heater. Therefore, while consumers cannot use standard test results to calculate their actual running costs, in general, any of the standards will reasonably predict relative running cost differences between models if used as part of the product selection process. While the correlation between the standards varies according to the capacity of the water heater, a simple approximation is developed to convert from the efficiency measured by one standard to another. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:468 / 478
页数:11
相关论文
共 51 条
[1]  
Aguilar C., 2005, DOMESTIC WATER HEATI
[2]  
American National Standards Institute, 2004, Z211032004CSA432004, VIII
[3]  
[Anonymous], 2011, BUILD EN DAT BOOK
[4]  
ASHRAE, 2006, 11822006 ASHRAE
[5]   TEST STANDARDS FOR HOUSEHOLD REFRIGERATORS AND FREEZERS .1. PRELIMINARY COMPARISONS [J].
BANSAL, PK ;
KRUGER, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (01) :4-20
[6]   Production efficiency of hot water for domestic use [J].
Boait, P. J. ;
Dixon, D. ;
Fan, D. ;
Stafford, A. .
ENERGY AND BUILDINGS, 2012, 54 :160-168
[7]   New test method for gas boosters with domestic solar water heaters [J].
Bourke, Grant ;
Bansal, Pradeep .
SOLAR ENERGY, 2012, 86 (01) :78-86
[8]   Energy consumption modeling of air source electric heat pump water heaters [J].
Bourke, Grant ;
Bansal, Pradeep .
APPLIED THERMAL ENGINEERING, 2010, 30 (13) :1769-1774
[9]  
Burch J, 2010, ACEEE HOT WAT FOR ON
[10]  
Butcher T, 2011, ASHRAE J, V53, P36