NUFFT-Based Algorithm for Near-field MMW Synthetic Aperture Imaging Radiometers

被引:0
作者
Yu, Mengjiao [1 ]
Li, Yuehua [1 ]
Chen, Jianfei [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect Engn & Optoelect Technol, Nanjing 210094, Jiangsu, Peoples R China
来源
PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC) | 2013年
关键词
MMW; near-field; synthetic aperture; imaging; NUFFT; algorithm; RECONSTRUCTION; INTERPOLATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The near-field MMW synthetic aperture imaging radiometer is very excellent imaging system for obtaining high resolution images. The corresponding imaging algorithms are usually established based on the conventional FFT with the uniform sampling of visibility function. But a lot of irregular antenna arrays appeared for some reason, such as the coordinate perturbation and the development of the synthetic aperture imaging system. And the visibility functions of these arrays are always random. The un-Cartesian sampling data are not distributed on the uniform grid points. For this random distribution of visibility function, the traditional FFT based on the uniform Cartesian sampling cannot image well. Thus we adopt NUFFT to reconstruct the images from the non-uniform visibility function samples in this paper. Based on the near-field imaging formulas, the accurate system functions are established in NUFFT algorithm. The effectiveness of the NUFFT is tested by the corresponding simulation experiments with 1D and 2D Target scenes. The results show that the NUFFT is an effective imaging algorithm for near-field MMW synthetic aperture imaging radiometer with arbitrary distribution of the visibility function.
引用
收藏
页码:527 / 531
页数:5
相关论文
共 14 条
  • [1] Rapid gridding reconstruction with a minimal oversampling ratio
    Beatty, PJ
    Nishimura, DG
    Pauly, JM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) : 799 - 808
  • [2] The processing of hexagonally sampled signals with standard rectangular techniques: Application to 2-D large aperture synthesis interferometric radiometers
    Camps, A
    Bara, J
    Sanahuja, IC
    Torres, F
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1997, 35 (01): : 183 - 190
  • [3] AN ACCURATE IMAGING ALGORITHM FOR MILLIMETER WAVE SYNTHETIC APERTURE IMAGING RADIOMETER IN NEAR-FIELD
    Chen, Jianfei
    Li, Yuehua
    Wang, Jianqiao
    Li, Yuanjiang
    Zhang, Yilong
    [J]. PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2013, 141 : 517 - 535
  • [4] Feng Yan-qiu, 2007, Acta Electronica Sinica, V35, P766
  • [5] Nonuniform fast Fourier transforms using min-max interpolation
    Fessler, JA
    Sutton, BP
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (02) : 560 - 574
  • [6] SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING
    JACKSON, JI
    MEYER, CH
    NISHIMURA, DG
    MACOVSKI, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 473 - 478
  • [7] [李白鸽 LI BaiGe], 2007, [中国医学物理学杂志, Chinese Journal of Medical Physics], V24, P322
  • [8] Two-Dimensional NUFFT-Based Algorithm for Fast Near-Field Imaging
    Li, Shiyong
    Sun, Houjun
    Zhu, Bocheng
    Liu, Rong
    [J]. IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2010, 9 : 814 - 817
  • [9] An accurate algorithm for nonuniform fast Fourier transforms (NUFFT's)
    Liu, QH
    Nguyen, N
    [J]. IEEE MICROWAVE AND GUIDED WAVE LETTERS, 1998, 8 (01): : 18 - 20
  • [10] Resampling of data between arbitrary grids using convolution interpolation
    Rasche, V
    Proksa, R
    Sinkus, R
    Börnert, P
    Eggers, H
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (05) : 385 - 392