Compensation of the Skin Effect in Low-Frequency Potential Drop Measurements

被引:22
作者
Corcoran, J. [1 ]
Nagy, P. B. [1 ,2 ]
机构
[1] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
[2] Univ Cincinnati, Dept Aerosp Engn & Engn Mech, Cincinnati, OH 45221 USA
基金
英国工程与自然科学研究理事会;
关键词
Potential drop; ACPD; DCPD; Skin effect; Creep monitoring; Minimum phase; ELEVATED-TEMPERATURES; GROWTH;
D O I
10.1007/s10921-016-0374-4
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Potential drop measurements are routinely used in the non-destructive evaluation of component integrity. Potential drop measurements use either direct current (DC) or alternating current (AC), the latter will have superior noise performance due to the ability to perform phase sensitive detection and the reduction of flicker noise. AC measurements are however subject to the skin effect where the current is electromagnetically constricted to the surface of the component. Unfortunately, the skin effect is a function of magnetic permeability, which in ferromagnetic materials is sensitive to a number of parameters including stress and temperature, and consequently in-situ impedance measurements are likely to be unstable. It has been proposed that quasi-DC measurements, which benefit from superior noise performance, but also tend to the skin-effect independent DC measurement, be adopted for in-situ creep measurements for power station components. Unfortunately, the quasi-DC measurement will only tend to the DC distribution and therefore some remnant sensitivity to the skin effect will remain. This paper will present a correction for situations where the remnant sensitivity to the skin effect is not adequately suppressed by using sufficiently low frequency; the application of particular interest being the in-situ monitoring of the creep strain of power station components. The correction uses the measured phase angle to approximate the influence of the skin effect and allow recovery of the DC-asymptotic value of the resistance. The basis of the correction, that poten-tial drop measurements are minimum phase is presented and illustrated on two cases; the creep strain sensor of practical interest and a conducting rod as another common case to illustrate generality. The correction is demonstrated experimentally on a component where the skin effect is manipulated by application of a range of elastic stresses.
引用
收藏
页数:12
相关论文
共 26 条
[1]  
[Anonymous], 2013, Model SR560 low-noise preamplifier
[2]  
[Anonymous], 1998, INTRO MAGNETISM MAGN
[3]  
[Anonymous], THESIS
[4]   Theory of four-point alternating current potential drop measurements on conductive plates [J].
Bowler, John R. ;
Bowler, Nicola .
PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2007, 463 (2079) :817-836
[5]   Theory of four-point alternating current potential drop measurements on a metal half-space [J].
Bowler, N .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (03) :584-589
[6]   Electrical conductivity measurement of metal plates using broadband eddy-current and four-point methods [J].
Bowler, N ;
Huang, YQ .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (11) :2193-2200
[7]   Nondestructive evaluation of thermally degraded 2.25Cr-1Mo steel by electrical resistivity measurement [J].
Byeon, JW ;
Kwun, SI .
MATERIALS TRANSACTIONS, 2003, 44 (06) :1204-1208
[8]   The use of DCPD method for measurement of growth of cracks in large components at normal and elevated temperatures [J].
Cerny, I .
ENGINEERING FRACTURE MECHANICS, 2004, 71 (4-6) :837-848
[9]  
Comsol Inc, 2015, COMS MULT
[10]  
Corcoran J., 2016, REV PROGR QUANTITATI, V35, DOI [10.1063/1.4940625, DOI 10.1063/1.4940625]