Mirror-image reversal of coronal computed tomography scans

被引:5
|
作者
Schmidt, D
Odland, R
机构
[1] Hennepin Cty Med Ctr, Dept Otolaryngol Head & Neck Surg, Minneapolis, MN 55415 USA
[2] Univ Minnesota, Sch Med, Dept Otolaryngol Head & Neck Surg, Minneapolis, MN 55455 USA
关键词
coronal computed tomography scans; computed tomography; image reversal; wrong-sided surgery;
D O I
10.1097/00005537-200409000-00011
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: Mirror-image reversal of coronal computed tomography (CT) scans can be a significant problem in patient care, potentially leading to wrong-sided surgery and malpractice suits. There is no literature describing the problem of mirror-image reversal of coronal CT scans. Generally, medical errors are not widely published: however, with the emphasis on reduction of errors in medicine, this topic should be openly discussed. Study Design: Retrospective review of patient care and an assessment of current methods. Methods: Two cases of mirror-image reversal of coronal CT scans were reviewed, and the authors found that each case represented a different type of error. In the first case, the error was recognized in the operating room. The second case resulted in wrong-sided surgery, and a lawsuit was filed. These two separate occurrences led to a review of the methods for determining right versus left side for orienting and labeling of CT scans. Orientation of coronal scans depends on whether the patient is prone or supine. Thus, technician input is required. If a labeling mistake is made, radiologists may not readily catch the mistake because of the symmetry of the head and neck anatomy. Results: A review of the markings on each scan should provide the otolaryngologist with enough information to determine whether the scan is mislabeled. Conclusion: The incidence of mislabeled coronal CT scans is unknown. This error can result in inappropriate patient care and lawsuits for wrong-sided surgery. Awareness of the potential problem and open discussion of interpretation and prevention are necessary.
引用
收藏
页码:1562 / 1565
页数:4
相关论文
共 50 条
  • [1] Carpal bone maturation assessment by image analysis from computed tomography scans
    Canovas, F
    Banegas, F
    Cyteval, C
    Jaeger, M
    DiMéglio, A
    Bonnel, F
    Sultan, C
    HORMONE RESEARCH, 2000, 54 (01) : 6 - 13
  • [2] In vivo measurements of muscle volume by automatic image analysis of spiral computed tomography scans
    Navajas, E. A.
    Glasbey, C. A.
    McLean, K. A.
    Fisher, A. V.
    Charteris, A. J. L.
    Lambe, N. R.
    Bunger, L.
    Simm, G.
    ANIMAL SCIENCE, 2006, 82 : 545 - 553
  • [3] Use of computed tomography scans for cochlear implants
    Whiting, Bruce R.
    Holden, Timothy A.
    Brunsden, Barry S.
    Finley, Charles C.
    Skinner, Margaret W.
    JOURNAL OF DIGITAL IMAGING, 2008, 21 (03) : 323 - 328
  • [4] Use of Computed Tomography Scans for Cochlear Implants
    Bruce R. Whiting
    Timothy A. Holden
    Barry S. Brunsden
    Charles C. Finley
    Margaret W. Skinner
    Journal of Digital Imaging, 2008, 21 : 323 - 328
  • [5] Computed navigated total knee arthroplasty compared to computed tomography scans
    Batash, Ron
    Rubin, Guy
    Lerner, Alexander
    Shehade, Hussein
    Rozen, Nimrod
    Rothem, David E.
    KNEE, 2017, 24 (03) : 622 - 626
  • [6] Preoperative computed tomography scans for parotid tumor evaluation
    Urquhart, A
    Hutchins, LG
    Berg, RL
    LARYNGOSCOPE, 2001, 111 (11) : 1984 - 1988
  • [7] Development of a chest phantom for testing in Computed Tomography scans
    Aburjaile, W. N.
    Mourao, A. P.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 275 - 277
  • [8] Multidetector spiral high-resolution computed tomography of the lungs:: Distribution of findings on coronal image reconstructions
    Johkoh, T
    Müller, NL
    Nakamura, H
    JOURNAL OF THORACIC IMAGING, 2002, 17 (04) : 291 - 305
  • [9] TELERADIOLOGY INTERPRETATIONS OF EMERGENCY DEPARTMENT COMPUTED TOMOGRAPHY SCANS
    Platts-Mills, Timothy F.
    Hendey, Gregory W.
    Ferguson, Brian
    JOURNAL OF EMERGENCY MEDICINE, 2010, 38 (02) : 188 - 195
  • [10] Effect of arm position on image quality and radiation dose during thorax and abdomen computed tomography scans
    Buchhave, E. O.
    Rasmussen, C. D.
    Lentz, R.
    Frederiksen, E. H.
    Kipp, J. O.
    Leftes, M. O.
    RADIOGRAPHY, 2024, 30 (04) : 1035 - 1040