An improved dual-channel capacitively coupled contactless conductivity detector with high detection performance

被引:4
|
作者
Nie, Hongyu [1 ]
Li, Zhihui [1 ]
Wang, Xiaokun [2 ]
Gu, Rongmeng [2 ]
Yuan, Hongyan [2 ]
Guo, Yong [1 ]
Xiao, Dan [1 ,2 ]
机构
[1] Sichuan Univ, Coll Chem, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Coll Chem Engn, Chengdu 610064, Peoples R China
基金
中国国家自然科学基金;
关键词
CAPILLARY-ELECTROPHORESIS; MICROCHIP ELECTROPHORESIS; CELL;
D O I
10.1039/d2an00330a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conductivity detectors are widely used electrochemical sensors. It has long been a goal of researchers to improve detection performance. In this contribution, we propose a multi-input capacitively coupled contactless conductivity detector ((MICD)-D-4) with high sensitivity, and we carry out a detailed theoretical investigation of the detector. In order to overcome the problem of a rising baseline level as a result of sensitivity improvements when using the multi-input detection method, we innovatively combine (MICD)-D-4 with differential detection to propose a further-improved detector ((DFMICD)-D-4). The detector is composed of two channels, one for the reference and the other for the analyte. The signal output from differential amplification can effectively reduce the high baseline level and detection interference. In KCl solution with a concentration range of 10(-4) to 10(-5) M, the response to the solution is a linear function of the logarithm of the concentration, and this detector has a high slope. The slope of (DFMICD)-D-4 is 1.393, higher than a traditional single-input capacitively coupled contactless conductivity detector ((CD)-D-4: 0.905) and a double-input capacitively coupled contactless conductivity detector ((DICD)-D-4: 1.314). For 10(-3) M KCl solution, the response-to-baseline ratio is 1.776 for (CD)-D-4, 1.779 for (DICD)-D-4, and 12.06 for (DFMICD)-D-4, with a ratio increase of nearly 6-fold shown by our new detector. At a S/N (signal-to-noise) ratio of 3, the limit of detection (LOD) of (DFMICD)-D-4 is low, reaching 0.7 nM. In addition, (DFMICD)-D-4 can be applied to the detection of low-conductivity solutions and total dissolved solids (TDS) analysis. Compared with a standard conductivity meter, our detector shows better detection performance.
引用
收藏
页码:2106 / 2114
页数:9
相关论文
共 50 条
  • [41] Application of capillary electrophoresis with capacitively contactless conductivity detection for biomedical analysis
    Elbashir, Abdalla A.
    Osman, Abdelbagi
    Elawad, Mohammed
    Ziyada, Abobakr K.
    Aboul-Enein, Hassan Y.
    ELECTROPHORESIS, 2024, 45 (5-6) : 400 - 410
  • [42] Application of capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D): An update
    Elbashir, Abdalla A.
    Schmitz, Oliver J.
    Aboul-Enein, Hassan Y.
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (09)
  • [43] Simultaneous determination of inorganic cations and anions by dual opposite ends injection coupled with capillary electrophoresis with capacitively contactless conductivity detection
    Tan, F
    Yang, BC
    Guan, YF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (03) : 313 - 316
  • [44] Determination of carbethopendecinium bromide in eye drops by capillary electrophoresis with capacitively coupled contactless conductivity detection
    Petru, Klara
    Jac, Pavel
    Sindelkova, Martina
    Polasek, Miroslav
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (10) : 1174 - 1179
  • [45] Determination of sildenafil and vardenafil by capillary zone electrophoresis using capacitively coupled contactless conductivity detection
    Rajh Vidal, Denis Tadeu
    Augelli, Marcio Antonio
    do Lago, Claudimir Lucio
    ANALYTICAL METHODS, 2013, 5 (08) : 2041 - 2045
  • [46] Rapid determination of meldonium in urine samples by capillary electrophoresis with capacitively coupled contactless conductivity detection
    Sampova, Andrea
    Kuban, Pavel
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1468 : 236 - 240
  • [47] Determination of Biogenic Amines in Seawater Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
    Gubartallah, Elbaleeq A.
    Makahleh, Ahmad
    Quirino, Joselito P.
    Saad, Bahruddin
    MOLECULES, 2018, 23 (05):
  • [48] A facile online multi-gear capacitively coupled contactless conductivity detector for an automatic and wide range monitoring of high salt in HPLC
    Liu, Weiwen
    Liang, Ziqi
    Wang, Yuanyu
    Cao, Jun
    Zhang, Qiang
    Liu, Xiaoping
    Wang, Yuxing
    Cao, Chengxi
    ANALYST, 2022, 147 (03) : 496 - 504
  • [49] Separation and determination of degradation products of acid orange 7 by capillary electrophoresis/capacitively coupled contactless conductivity detector
    Wang, Xin
    Xiong, Ya
    Xie, Tianyao
    Sharma, Virender K.
    Tu, Yuting
    Yang, Jiannan
    Tian, Shuanghong
    He, Chun
    TALANTA, 2013, 111 : 54 - 61
  • [50] A contactless conductivity detector for capillary electrophoresis:: Effects of the detection cell geometry on the detector performance
    Tuma, P
    Opekar, F
    Stulík, K
    ELECTROPHORESIS, 2002, 23 (21) : 3718 - 3724