Measurements of SRM 981 Pb isotope standard mixed with Tl for mass bias corrections were conducted with a MC-ICP-MS (Nu Plasma) using a Nu Instruments desolvating nebulizer. During the initial experiments, Pb and Tl from single-element, concentrated stock solutions were mixed in 2% HNO3 prior to isotope ratio measurements. The results revealed relatively poor precision and accuracy of the Pb isotope measurements, large variations in epsilon(205)Tl in the same standard (ranging from -3.9 to +30.1), and large variations in the observed Pb/Tl intensity ratios. When analyses were restricted to freshly mixed (<1 hour) Pb-Tl solutions, however, highly precise isotopic ratios were obtained for lead (Pb-206/Pb-204=16.9373(±0.0011, 2σ), Pb-207/Pb-204=15.4907 (±0.0012, 2σ), and Pb-208/Pb-204=36.6935 (0.0039, 2σ)) and for thallium (εTl-205=1.5 (±0.8, 2σ)). In addition, Pb/Tl intensity ratios were constant and corresponded to the mixing ratios of the prepared solutions. A series of experiments revealed that the poor precision and accuracy observed for the initial set of isotope ratio measurements resulted from variable photoxidation of Tl+ to Tl3+, which occurs in the presence of Pb and solar UV radiation. This reversible reaction generates Tl3+, which behaves distinctly from Tl+ during desolvation and leads to consistently higher measured Pb/Tl and Tl-205/Tl-203 ratios. The extent of the interaction between Pb and Tl and the subsequent effect on isotope ratio measurements is sensitive to a combination of factors, including differences in the acid matrix and molarity, desolvation conditions, and UV light exposure. It appears that the observed εTl-205 variations in the Pb-Tl3+-bearing solutions dominantly result from mass-dependant differential diffusion of Tl during desolvation. These experiments suggest that great care must be exercised during isotopic analyses of systems utilizing one element for mass-bias correction on another, such as Pb-Tl, Cu-Zn and Mo-Zr, which readily undergo redox reactions under laboratory conditions.
引用
收藏
页码:1262 / 1267
页数:6
相关论文
共 22 条
[1]   PHOTOELECTROCHEMISTRY [J].
BARD, AJ .
SCIENCE, 1980, 207 (4427) :139-144
[2]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[3]  
BURGESS J, 1978, METAL IONS SOLUTION, P481
[4]  
Choppin G. R, 2002, RADIOCHEMISTRY NUCL, P709
[5]   Applications of accurate, high-precision Pb isotope ratio measurement by multi-collector ICP-MS [J].
Collerson, KD ;
Kamber, BS ;
Schoenberg, R .
CHEMICAL GEOLOGY, 2002, 188 (1-2) :65-83
[6]  
Cotton FA, 1999, ADV INORG CHEM, P1355
[7]  
KAMENOV G, 2004, UNPUB CHEM GEOL
[8]   Thallium speciation in river waters with Chelex-100 resin [J].
Lin, TS ;
Nriagu, JO .
ANALYTICA CHIMICA ACTA, 1999, 395 (03) :301-307
[9]  
NIELSEN SG, 2004, IN PRESS CHEM GEOL
[10]   The precise measurement of T1 isotopic compositions by MC-ICPMS:: Application to the analysis of geological materials and meteorites [J].
Rehkämper, M ;
Halliday, AN .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1999, 63 (06) :935-944