Mathematical simulation of DC arc furnace operation in electric power systems

被引:0
作者
Stade, D [1 ]
Schau, H [1 ]
Aprelkov, I [1 ]
Novitskiy, A [1 ]
机构
[1] Tech Univ Ilmenau, D-98684 Ilmenau, Germany
来源
8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2 | 1998年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modern high-power D.C. electric are furnaces (DC EAF) are considerable sources of power quality impacts in the electric supply systems. These impacts result from the feeding converters, but particularly also from the electric are In the D.C. circuit. For an exact analysis of the DC EAF influence on the electric network, both the converter and the electric are have to be mathematically modelled. The paper presents the results of on-site measurements at a real high-power DC EAF as well as, based on it, a new mathematical approach of the electrical EAF behaviour.
引用
收藏
页码:1086 / 1091
页数:6
相关论文
共 5 条
[1]  
Ahlers H., 1987, Elektrowaerme International, Edition B, V45, pB224
[2]  
ISCHUTIN P, 1998, THESIS TU ILMENAU IL, P93
[3]  
SISOYAN GA, 1994, ELEKTRICHESKAYA DUGA
[4]  
STADE D, 1997, P C UPEC 97 MANCH EN, P859
[5]  
STADE D, 1997, P C EPQU 97 CRAC POL, P375