Electrical impedance tomography during major open upper abdominal surgery: a pilot-study

被引:29
作者
Schaefer, Maximilian S. [1 ]
Wania, Viktoria [1 ]
Bastin, Bea [1 ]
Schmalz, Ursula [1 ]
Kienbaum, Peter [1 ]
Beiderlinden, Martin [1 ,2 ]
Treschan, Tanja A. [1 ]
机构
[1] Univ Dusseldorf, Duesseldorf Univ Hosp, Dept Anaesthesiol, D-40225 Dusseldorf, Germany
[2] Marien Hosp, Dept Anaesthesiol, D-49074 Osnabruck, Germany
来源
BMC ANESTHESIOLOGY | 2014年 / 14卷
关键词
Electrical impedance tomography; General anesthesia; Abdominal surgery; Atelectasis; Lung function; RESPIRATORY-DISTRESS-SYNDROME; MECHANICALLY VENTILATED PATIENTS; END-EXPIRATORY PRESSURE; TIDAL VOLUMES; REGIONAL VENTILATION; LUNG VENTILATION; ANESTHESIA; BEDSIDE; TRIAL;
D O I
10.1186/1471-2253-14-51
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Electrical impedance tomography (EIT) of the lungs facilitates visualization of ventilation distribution during mechanical ventilation. Its intraoperative use could provide the basis for individual optimization of ventilator settings, especially in patients at risk for ventilation-perfusion mismatch and impaired gas exchange, such as patients undergoing major open upper abdominal surgery. EIT throughout major open upper abdominal surgery could encounter difficulties in belt positioning and signal quality. Thus, we conducted a pilot-study and tested whether EIT is feasible in patients undergoing major open upper abdominal surgery. Methods: Following institutional review board's approval and written informed consent, we included patients scheduled for major open upper abdominal surgery of at least 3 hours duration. EIT measurements were conducted prior to intubation, at the time of skin incision, then hourly during surgery until shortly prior to extubation and after extubation. Number of successful intraoperative EIT measurements and reasons for failures were documented. From the valid measurements, a functional EIT image of changes in tidal impedance was generated for every time point. Regions of interest were defined as horizontal halves of the picture. Monitoring of ventilation distribution was assessed using the center of ventilation index, and also using the total and dorsal ventilated lung area. All parameter values prior to and post intubation as well as extubation were compared. A p < 0.05 was considered statistically significant. Results: A total of 120 intraoperative EIT measurements during major abdominal surgery lasting 4-13 hours were planned in 14 patients. The electrode belt was attached between the 2nd and 4th intercostal space. Consecutive valid measurements could be acquired in 13 patients (93%). 111 intraoperative measurements could be retrieved as planned (93%). Main obstacle was the contact of skin electrodes. Despite the high belt position, distribution of tidal volume showed a significant shift of ventilation towards ventral lung regions after intubation. This was reversed after weaning from mechanical ventilation. Conclusions: Despite a high belt position, monitoring of ventilation distribution is feasible in patients undergoing major open upper abdominal surgery lasting from 4 to 13 hours. Therefore, further interventional trials in order to optimize ventilatory management should be initiated.
引用
收藏
页数:8
相关论文
共 20 条
  • [1] Bioimpedance imaging: an overview of potential clinical applications
    Bayford, Richard
    Tizzard, Andrew
    [J]. ANALYST, 2012, 137 (20) : 4635 - 4643
  • [2] Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial
    Bikker, Ido G.
    Preis, Carsten
    Egal, Mahamud
    Bakker, Jan
    Gommers, Diederik
    [J]. CRITICAL CARE, 2011, 15 (04):
  • [3] Lung monitoring at the bedside in mechanically ventilated patients
    Blankman, Paul
    Gommers, Diederik
    [J]. CURRENT OPINION IN CRITICAL CARE, 2012, 18 (03) : 261 - 266
  • [4] Principles of electrical impedance tomography and its clinical application
    Bodenstein, Marc
    David, Matthias
    Markstaller, Klaus
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (02) : 713 - 724
  • [5] Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
    Costa, Eduardo L. V.
    Borges, Joao Batista
    Melo, Alexandre
    Suarez-Sipmann, Fernando
    Toufen, Carlos, Jr.
    Bohm, Stephan H.
    Amato, Marcelo B. P.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (06) : 1132 - 1137
  • [6] Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery
    Erlandsson, K.
    Odenstedt, H.
    Lundin, S.
    Stenqvist, O.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (07) : 833 - 839
  • [7] Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography
    Frerichs, I
    Hahn, G
    Golisch, W
    Kurpitz, M
    Burchardi, H
    Hellige, G
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) : 721 - 726
  • [8] Lung volume recruitment after surfactant administration modifies spatial distribution of ventilation
    Frerichs, Inez
    Dargaville, Peter A.
    van Genderingen, Huibert
    Morel, Denis R.
    Rimensberger, Peter C.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 174 (07) : 772 - 779
  • [9] EFFECTS OF ANESTHESIA AND PARALYSIS ON DIAPHRAGMATIC MECHANICS IN MAN
    FROESE, AB
    BRYAN, AC
    [J]. ANESTHESIOLOGY, 1974, 41 (03) : 242 - 255
  • [10] Ventilator settings as a risk factor for acute respiratory distress syndrome in mechanically ventilated patients
    Gajic, O
    Frutos-Vivar, F
    Esteban, A
    Hubmayr, RD
    Anzueto, A
    [J]. INTENSIVE CARE MEDICINE, 2005, 31 (07) : 922 - 926