Array of peptide-modified electrodes for the simultaneous determination of Pb(II), Cd(II) and Zn(II)

被引:42
作者
Serrano, Nuria [1 ,2 ]
Prieto-Simon, Beatriz [2 ,3 ]
Ceto, Xavier [2 ]
del Valle, Manel [2 ]
机构
[1] Univ Barcelona, Fac Chem, Dept Analyt Chem, E-08028 Barcelona, Spain
[2] Univ Autonoma Barcelona, Dept Chem, Sensors & Biosensors Grp, Bellaterra 08193, Spain
[3] Univ S Australia, Mawson Inst, Mawson Lakes, SA 5001, Australia
关键词
Peptide-modified sensors; Electrochemical grafting; Metal determination; Stripping voltammetry; Quatrilinear data; Artificial neural network; DIFFERENTIAL-PULSE POLAROGRAPHY; MULTIVARIATE CURVE RESOLUTION; GAMMA-GLU-CYS; COMPETITIVE-BINDING; MASS-SPECTROMETRY; COMPLEXATION; GLUTATHIONE; VOLTAMMETRY; CADMIUM; IONS;
D O I
10.1016/j.talanta.2014.02.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the development of three peptide modified sensors in which glutathione (GSH) and its fragments Cys-Gly and gamma-Glu-Cys were immobilized respectively through aryl diazonium electrochemical grafting onto the surface of graphite-epoxy composite electrodes (GEC), and used for the simultaneous determination of Cd(II), Pb(II) and Zn(II). The concentration interval ranged from 0.1 to 1.5 mu mol L-1 for each metal, and the technique used was differential pulse adsorptive stripping voltammetry. This study aimed to the comparison of the information provided by one single modified electrode at both fixed and multiple pH values (pH 6.8, 7.5 and 8.2) for the simultaneous determination of the three metals, with those supplied by the three-sensor array at multiple pH values. For the processing of the voltammograms, the fast Fourier transform was selected as the preprocessing tool for data compression coupled with an artificial neural network for the modeling of the obtained responses. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 32 条
  • [1] Soft modelling for the resolution of highly overlapped voltammetric peaks:: application to some Pb-phytochelatin systems
    Alberich, Aristides
    Arino, Cristina
    Diaz-Cruz, Jose Manuel
    Esteban, Miquel
    [J]. TALANTA, 2007, 71 (01) : 344 - 352
  • [2] Bismuth film electrodes for the study of metal thiolate complexation: An alternative to mercury electrodes
    Alberich, Aristides
    Serrano, Nuria
    Arino, Cristina
    Diaz-Cruz, Jose Manuel
    Esteban, Miquel
    [J]. TALANTA, 2009, 78 (03) : 1017 - 1022
  • [3] Voltammetric Analysis of Phytochelatin Complexation in Ternary Metal Mixtures Supported by Multivariate Analysis and ESI-MS
    Cavanillas, Santiago
    Gusmao, Rui
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    [J]. ELECTROANALYSIS, 2012, 24 (02) : 309 - 315
  • [4] Comparison of methods for the processing of voltammetric electronic tongues data
    Ceto, Xavier
    Cespedes, Francisco
    del Valle, Manel
    [J]. MICROCHIMICA ACTA, 2013, 180 (5-6) : 319 - 330
  • [5] Resolution of phenolic antioxidant mixtures employing a voltammetric bio-electronic tongue
    Ceto, Xavier
    Cespedes, Francisco
    Isabel Pividori, Maria
    Manuel Gutierrez, Juan
    del Valle, Manel
    [J]. ANALYST, 2012, 137 (02) : 349 - 356
  • [6] Voltammetric Electronic Tongue in the Analysis of Cava Wines
    Ceto, Xavier
    Manuel Gutierrez, Juan
    Moreno-Baron, Laura
    Alegret, Salvador
    del Valle, Manel
    [J]. ELECTROANALYSIS, 2011, 23 (01) : 72 - 78
  • [7] Competitive binding of Cd and Zn with the phytochelatin (γ-Glu-Cys)4-Gly:: Comparative study by mass spectrometry, voltammetry-multivariate curve resolution, and isothermal titration calorimetry
    Chekmeneva, Elena
    Prohens, Rafel
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miquel
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (08) : 2860 - 2866
  • [8] Thermodynamics of Cd2+ and Zn2+ binding by the phytochelatin (γ-Glu-Cys)4-Gly and its precursor glutathione
    Chekmeneva, Elena
    Prohens, Rafel
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miquel
    [J]. ANALYTICAL BIOCHEMISTRY, 2008, 375 (01) : 82 - 89
  • [9] Voltammetric detection of cadmium ions at glutathione-modified gold electrodes
    Chow, E
    Hibbert, DB
    Gooding, JJ
    [J]. ANALYST, 2005, 130 (06) : 831 - 837
  • [10] Chow E, 2007, COMP ANAL C, V49, pE83, DOI 10.1016/S0166-526X(06)49056-5