Potentiometric flow injection determination of serum bromide in patients with epilepsy

被引:13
作者
Katsu, T [1 ]
Mori, Y [1 ]
Matsuka, N [1 ]
Gomita, Y [1 ]
机构
[1] OKAYAMA UNIV,SCH MED,DEPT HOSP PHARM,OKAYAMA 700,JAPAN
关键词
flow injection analysis; ion-selective electrode; bromide; therapeutic drug monitoring; epilepsy;
D O I
10.1016/S0731-7085(96)02017-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection system was constructed using a bromide-selective electrode and used to determine serum bromide in patients with epilepsy. A 10-mu l serum sample was injected into a carrier stream flowing at 0.12 mi min(-1). Potential changes and bromide concentrations were linearly related in the range 3-50 mM. The lower limit of detection for serum bromide was 1 mM and this electrode sensitivity spanned the entire concentration range required for bromide therapy (9-24 mM). The results compared favourably with those obtained by colorimetry. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1829 / 1832
页数:4
相关论文
共 50 条
[41]   ENZYMATIC DETERMINATION OF BICARBONATE IN SERUM BY FLOW-INJECTION ANALYSIS [J].
QUILES, R ;
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
CLINICA CHIMICA ACTA, 1995, 235 (02) :169-177
[42]   Determination of Trace Nickel in Natural Water by Flow Injection Analysis with Cetrimonium Bromide as Sensitizer [J].
Z. X. Zhao ;
C. X. Zhang ;
N. Li ;
X. S. Zhang .
Journal of Applied Spectroscopy, 2015, 82 :882-887
[43]   Determination of Trace Nickel in Natural Water by Flow Injection Analysis with Cetrimonium Bromide as Sensitizer [J].
Zhao, Z. X. ;
Zhang, C. X. ;
Li, N. ;
Zhang, X. S. .
JOURNAL OF APPLIED SPECTROSCOPY, 2015, 82 (05) :882-887
[44]   Flow injection potentiometric determination of Fe(III) using a fluoride-selective electrode as detector [J].
Bralic, M ;
Radic, N .
ANALUSIS, 1999, 27 (01) :57-60
[45]   Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system [J].
José L. F. C. Lima ;
M. C. B. S. M. Montenegro ;
Ana P. M. M. O. Pinto .
Fresenius' Journal of Analytical Chemistry, 1999, 364 :353-357
[46]   Interference Effect of Various Ions on Determination of Iron with Flow Injection Analysis Using the Potentiometric Technique [J].
Bralic, Marija ;
Buljac, Masa ;
Buzuk, Marijo ;
Brinic, Slobodan .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04) :2928-2937
[47]   Flow injection determination of anisidine value in palm oil samples using a triiodide potentiometric detector [J].
Saad, Bahruddin ;
Wai, Wan Tatt ;
Lim, Boey Peng ;
Saleh, Muhammad Idiris .
ANALYTICA CHIMICA ACTA, 2007, 591 (02) :248-254
[48]   Determination of SO2 in wines using a flow injection analysis system with potentiometric detection [J].
Araújo, AN ;
Couto, CMCM ;
Lima, JLFC ;
Montenegro, MCBSM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (01) :168-172
[49]   SEQUENTIAL FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF IODIDE AND IODINE IN POVIDONE-IODINE PHARMACEUTICALS [J].
HASSAN, SSM ;
MARZOUK, SAM .
ELECTROANALYSIS, 1993, 5 (9-10) :855-861
[50]   Novel PVC-membrane electrode for flow injection potentiometric determination of Biperiden in pharmaceutical preparations [J].
Khaled, Elmorsy ;
EI-Sabbagh, Inas A. ;
El-Kholy, N. G. ;
Ghahni, E. Y. Abdel .
TALANTA, 2011, 87 :40-45