Potentiometric flow injection determination of serum bromide in patients with epilepsy

被引:13
作者
Katsu, T [1 ]
Mori, Y [1 ]
Matsuka, N [1 ]
Gomita, Y [1 ]
机构
[1] OKAYAMA UNIV,SCH MED,DEPT HOSP PHARM,OKAYAMA 700,JAPAN
关键词
flow injection analysis; ion-selective electrode; bromide; therapeutic drug monitoring; epilepsy;
D O I
10.1016/S0731-7085(96)02017-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection system was constructed using a bromide-selective electrode and used to determine serum bromide in patients with epilepsy. A 10-mu l serum sample was injected into a carrier stream flowing at 0.12 mi min(-1). Potential changes and bromide concentrations were linearly related in the range 3-50 mM. The lower limit of detection for serum bromide was 1 mM and this electrode sensitivity spanned the entire concentration range required for bromide therapy (9-24 mM). The results compared favourably with those obtained by colorimetry. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1829 / 1832
页数:4
相关论文
共 50 条
  • [31] β-Cyclodextrin-Based Potentiometric Sensors for Flow-Injection Determination of Acetylcholines
    Khaled, Elmorsy
    Hassan, H. N. A.
    Mohamed, Gehad G.
    Ragab, Fahem A.
    Seleim, Aly Eldin A.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (04): : 448 - 458
  • [32] Determination of nitrate in carbon black by flow injection analysis (FIA) with potentiometric detection
    Canal, IG
    Lima, JLFC
    Montenegro, MCBSM
    PrezOlmos, R
    [J]. ANALUSIS, 1997, 25 (02) : 32 - 35
  • [33] Flow injection determination of bromide ion in a developer using bromide ion-selective electrode detector
    Masadome, T
    Asano, Y
    Nakamura, T
    [J]. TALANTA, 1999, 50 (03) : 595 - 600
  • [34] Potentiometric flow injection analysis of drotaverine hydrochloride in pharmaceutical preparations
    Ibrahim, H
    Issa, YM
    Abu-Shawish, HM
    [J]. ANALYTICAL LETTERS, 2005, 38 (01) : 111 - 132
  • [35] Determination of orciprenaline using a flow injection analysis system with sequential potentiometric and spectrophotometric detection
    El Nashar, Rasha Mohamed
    [J]. ANALYTICAL LETTERS, 2008, 41 (06) : 949 - 964
  • [36] Membrane sensors for batch and flow injection potentiometric determination of ethamsylate (Cyclonamine) in pharmaceutical preparations
    Hassan, SSM
    ElBahnasawy, RM
    Rizk, NM
    [J]. MIKROCHIMICA ACTA, 1997, 126 (3-4) : 217 - 222
  • [37] Flow Injection Potentiometric Determination of Terazosin Hydrochloride Using Modified Carbon Paste Electrodes
    Zayed, Sayed I. M.
    Khalil, Mohamed M.
    Issa, Yousry M.
    Khalefa, Huda R.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (05): : 2327 - 2340
  • [38] Sequential determination of chromium(VI) and chromium(III) by potentiometric flow-injection method
    Ohura, H
    Imato, T
    Matsuo, I
    Yamasaki, S
    [J]. BUNSEKI KAGAKU, 2000, 49 (01) : 59 - 64
  • [39] Membrane sensors for batch and flow injection potentiometric determination of ethamsylate (cyclonamine) in pharmaceutical preparations
    Saad S. M. Hassan
    Ramadan M. El-Bahnasawy
    Nashwa M. Rizk
    [J]. Microchimica Acta, 1997, 126 : 217 - 222
  • [40] A manganese porphyrin-based sensor for flow-injection potentiometric determination of thiocyanate
    Beheshti, Saeed S.
    Sohbat, Fatemeh
    Amini, Mohammad K.
    [J]. JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2010, 14 (02) : 158 - 165