Wound Integrity of Clear Corneal Incisions Closed with Fibrin and N-Butyl-2-Cyanoacrylate Adhesives

被引:26
作者
Banitt, Michael [1 ]
Soong, H. Kaz [1 ]
Mian, Shahzad I. [1 ]
Malta, Joao Baptista [1 ,2 ]
Musch, David C. [1 ,3 ]
机构
[1] Univ Michigan, Dept Ophthalmol & Visual Sci, WK Kellogg Eye Ctr, Sch Med, Ann Arbor, MI 48105 USA
[2] Santa Casa Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[3] Univ Michigan, Sch Publ Hlth, Dept Epidemiol, Ann Arbor, MI 48109 USA
关键词
clear corneal incision; cyanoacrylate adhesive; fibrin adhesive; AUTOMATED ENDOTHELIAL KERATOPLASTY; 2-OCTYL CYANOACRYLATE; CATARACT INCISIONS; LABORATORY MODEL; TISSUE ADHESIVES; IN-VITRO; ENDOPHTHALMITIS; PERFORATIONS; GLUE;
D O I
10.1080/02713680903019993
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the integrity of clear corneal incisions closed with fibrin (Tisseel(R)) and n-butyl-2-cyanoacrylate (Histoacryl(R)) tissue adhesives to those closed with conventional sutures. Methods: Four replicate experiments were performed on porcine eyes with each of the following conditions: three limbal clear corneal incision sizes (3.0 mm, 4.5 mm, and 6.0 mm), three incision closure techniques (fibrin adhesive, n-butyl-2-cyanoacrylate adhesive, and 10-0 interrupted nylon sutures)1, 2, and 3 sutures at the 3.0-mm, 4.5-mm, and 6.0-mm incision sizes, respectively. Wound integrity was then measured by elevating the intraocular pressure of the eye to the point where wound leakage (IOPL) occurred. Two-way repeated measures analysis of variance (ANOVA) was used to analyze the IOPL data. Results: Incision closure technique and incision size showed significant interaction in the ANOVA model (p = 0.0008). Fibrin adhesive demonstrated higher IOPL compared to suture closure at the 3.0-mm incision size (p < 0.0001). There was no significant difference in IOPL when comparing wound closure with fibrin adhesive and sutures at the 4.5-mm and 6.0-mm incision sizes (p = 0.52 and p = 0.56, respectively). There was no significant difference between the three closure techniques for the 6.0-mm incisions (p > 0.15). When comparing the wound closure techniques for all incision sizes, the mean IOPL significantly increased in the following order: suture(s), fibrin adhesive, n-butyl-2-cyanoacrylate glue. Conclusions: Fibrin or n-butyl-2-cyanoacrylate tissue adhesive may be used as a more stable alternative to conventional sutures in the closure of clear corneal incisions.
引用
收藏
页码:706 / 710
页数:5
相关论文
共 19 条
[1]   Polysaccharide-based tissue adhesives for sealing corneal incisions [J].
Bhatia, Sujata K. ;
Arthur, Samuel D. ;
Chenault, H. Keith ;
Figuly, Garret D. ;
Kodokian, George K. .
CURRENT EYE RESEARCH, 2007, 32 (12) :1045-1050
[2]   Comparison of the bacteriostatic effects, corneal cytotoxicity, and the ability to seal corneal incisions among three different tissue adhesives [J].
Chen, Wei-Li ;
Lin, Chung-Tien ;
Hsieh, Chia-Yun ;
Tu, I-Hua ;
Chen, Willie Y. W. ;
Hu, Fung-Rong .
CORNEA, 2007, 26 (10) :1228-1234
[3]   CYANOACRYLATES AND CORNEAL ABRASION [J].
DEAN, BS ;
KRENZELOK, EP .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1989, 27 (03) :169-172
[4]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889
[5]   Watertight cataract incision closure using fibrin tissue adhesive [J].
Hovanesian, John A. ;
Karageozian, Vicken H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08) :1461-1463
[6]   Early results of small-incision Descemet's stripping and automated endothelial keratoplasty [J].
Koenig, Steven B. ;
Covert, Douglas J. .
OPHTHALMOLOGY, 2007, 114 (02) :221-226
[7]   A FIBRIN SEALANT FOR PERFORATED AND PREPERFORATED CORNEAL ULCERS [J].
LAGOUTTE, FM ;
GAUTHIER, L ;
COMTE, PRM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (09) :757-761
[8]   Practice styles and preferences of ASCRS members - 2003 survey [J].
Leaming, DV .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04) :892-900
[9]   Preliminary in vitro evaluation of 2-octyl cyanoacrylate (Dermabond®) to seal corneal incisions [J].
Leung, GYS ;
Peponis, V ;
Varnell, ED ;
Lam, DSC ;
Kaufman, HE .
CORNEA, 2005, 24 (08) :998-999
[10]  
Manzano RPD, 2006, CORNEA, V25, P350