Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection

被引:55
作者
Li, Qing
Wang, Long-Fei
Ma, Wei-Guo
Xu, Shang-Dong
Zheng, Jun
Xing, Xiao-Yan
Huang, Lian-Jun
Sun, Li-Zhong
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Beijing Aort Dis Ctr, Beijing Inst Heart Lung & Blood Vessel Dis, Beijing 100029, Peoples R China
[2] Beijing Engn Res Ctr Vasc Prostheses, Beijing 100029, Peoples R China
关键词
Aortic dissection; type B; endovascular; stent graft; new entry; STEEL-BASED DEVICE; BARE STENT; PLACEMENT;
D O I
10.3978/j.issn.2072-1439.2015.11.27
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Distal stent graft-induced new entry (DSINE) has been increasingly observed following thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD). We seek to identify the risk factors for DSINE following TEVAR in patients with TBAD. Methods: Between January 2009 and January 2013, we performed TEVAR for 579 patients with TBAD. The clinical data were retrospectively analyzed with univariate and multivariate analyses to identify the risk factors for DSINE. Results: Two patients (0.3%) died after the initial TEVAR. Morbidity included spinal cord injury in 2 (0.3%), stroke in 3 (0.5%) and endoleak in 12 (2.1%) patients. Clinical and radiological follow-up was complete in 100% (577/577) averaging 47 +/- 16 months. Late death occurred in 6 patients. DSINE occurred in 39 patients (6.7%) at mean 22 +/- 17 months after the initial TEVAR, which was managed with re-TEVAR in 25 and medically in 14. At 33 +/- 18 months after DSINE, 11 of patients managed medically (11/14) and all patients managed with re-TEVAR (25/25) survived (P=0.048). Freedom from DSINE was 92.7% at 5 years (95% CI: 90.0-94.7%). Using tapered stent grafts with a proximal end 4-8 mm larger than the distal end, TEVAR performed in the acute phase (<= 14 days from onset) was associated with a significantly lower incidence of DSINE than TEVAR performed in the chronic phase (4.3%, 7/185 vs. 13.9%, 15/108; P=0.003). Risk factors for DSINE were stent grafts less than 145 mm in length [odds ratio (OR) 2.268; 95% CI: 1.121-4.587; P=0.023] and TEVAR performed in the chronic phase (OR 1.935; 95% CI: 1.004-3.731; P=0.049). Conclusions: Our results show that TEVAR performed during the acute phase and using stent grafts longer than 145 mm could decrease the incidence of DSINE in patients with TBAD. Tapered stent grafts with a proximal end 4-8 mm larger than the distal end may be helpful in preventing DSINE after TEVAR performed in the acute phase than TEVAR performed in the chronic phase, due to the difference in mobility of the dissected flap. Expedite repeat TEVAR is recommended to improve the clinical prognosis for patients with DSINE.
引用
收藏
页码:1907 / 1916
页数:10
相关论文
共 22 条
[1]   Current management and outcome of chronic type B aortic dissection: results with open and endovascular repair since the advent of thoracic endografting [J].
Andersen, Nicholas D. ;
Keenan, Jeffrey E. ;
Ganapathi, Asvin M. ;
Gaca, Jeffrey G. ;
McCann, Richard L. ;
Hughes, G. Chad .
ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (03) :264-274
[2]   Endovascular stent-graft placement for the treatment of acute aortic dissection [J].
Dake, MD ;
Kato, N ;
Mitchell, RS ;
Semba, CP ;
Razavi, MK ;
Shimono, T ;
Hirano, T ;
Takeda, K ;
Yada, I ;
Miller, DC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) :1546-1552
[3]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[4]   Retrograde Type A Aortic Dissection After Endovascular Stent Graft Placement for Treatment of Type B Dissection [J].
Dong, Zhi Hui ;
Fu, Wei Guo ;
Wang, Yu Qi ;
Guo, Da Qiao ;
Xu, Xin ;
Ji, Yuan ;
Chen, Bin ;
Jiang, Jun Hao ;
Yang, Jue ;
Shi, Zhen Yu ;
Zhu, Ting ;
Shi, Yun .
CIRCULATION, 2009, 119 (05) :735-U133
[5]   Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection [J].
Dong, Zhihui ;
Fu, Weiguo ;
Wang, Yuqi ;
Wang, Chunsheng ;
Yan, Zhiping ;
Guo, Daqiao ;
Xu, Xin ;
Chen, Bin .
JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) :1450-1457
[6]   Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection [J].
Feng, Jiaxuan ;
Lu, Qingsheng ;
Zhao, Zhiqing ;
Bao, Junmin ;
Feng, Xiang ;
Qu, Lefeng ;
Zhou, Jian ;
Jing, Zaiping .
JOURNAL OF VASCULAR SURGERY, 2013, 57 :44S-52S
[7]   Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection [J].
He, H. ;
Yao, K. ;
Nie, W. P. ;
Wang, Z. ;
Liang, Q. ;
Shu, C. ;
Dardik, A. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (04) :450-459
[8]   Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection [J].
Huang, Chun-Yang ;
Weng, Shih-Hsien ;
Weng, Chi-Feng ;
Chen, Wei-Yuan ;
Chen, I-Ming ;
Hsu, Chiao-Po ;
Shih, Chun-Che .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (03) :623-630
[9]   Thoracic Endovascular Aortic Repair for Chronic DeBakey IIIb Aortic Dissection [J].
Hughes, G. Chad ;
Ganapathi, Asvin M. ;
Keenan, Jeffrey E. ;
Englum, Brian R. ;
Hanna, Jennifer M. ;
Schechter, Matthew A. ;
Wang, Hanghang ;
McCann, Richard L. .
ANNALS OF THORACIC SURGERY, 2014, 98 (06) :2092-2098
[10]   Thoracic Aortic Aneurysm Expansion Due to Late Distal Stent Graft-Induced New Entry [J].
Janosi, Rolf Alexander ;
Tsagakis, Konstantinos ;
Bettin, Markus ;
Kahlert, Philipp ;
Horacek, Michael ;
Al-Rashid, Fadi ;
Schlosser, Thomas ;
Jakob, Heinz ;
Eggebrecht, Holger ;
Erbel, Raimund .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (02) :E43-E53