Model-Based Design and Optimization of Blood Oxygenators

被引:6
作者
He, Ge [1 ]
Zhang, Tao [2 ]
Zhang, Jiafeng [1 ]
Griffith, Bartley P. [1 ]
Wu, Zhongjun J. [1 ,3 ]
机构
[1] Univ Maryland, Sch Med, Dept Surg, 10 South Pine St, Baltimore, MD 21201 USA
[2] Abiomed Inc, 22 Cherry Hill Dr, Danvers, MA 01923 USA
[3] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2020年 / 14卷 / 04期
基金
美国国家卫生研究院;
关键词
hollow fiber membrane; artificial lung; oxygen transfer; porous media; empirical model; MATHEMATICAL-MODEL; MASS-TRANSFER; TRANSFER RATES; FLUID-FLOW; IN-VITRO; DEVICES;
D O I
10.1115/1.4047872
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood oxygenators, also known as artificial lungs, are widely used in cardiopulmonary bypass surgery to maintain physiologic oxygen (O-2) and carbon dioxide (CO2) levels in blood, and also serve as respiratory assist devices to support patients with lung failure. The time- and cost-consuming method of trial and error is initially used to optimize the oxygenator design, and this method is followed by the introduction of the computational fluid dynamics (CFD) that is employed to reduce the number of prototypes that must be built as the design is optimized. The CFD modeling method, while having progress in recent years, still requires complex three-dimensional (3D) modeling and experimental data to identify the model parameters and validate the model. In this study, we sought to develop an easily implemented mathematical models to predict and optimize the performance (oxygen partial pressure/saturation, oxygen/carbon dioxide transfer rates, and pressure loss) of hollow fiber membrane-based oxygenators and this model can be then used in conjunction with CFD to reduce the number of 3D CFD iteration for further oxygenator design and optimization. The model parameters are first identified by fitting the model predictions to the experimental data obtained from a mock flow loop experimental test on a mini fiber bundle. The models are then validated through comparing the theoretical results with the experimental data of seven full-size oxygenators. The comparative analysis show that the model predictions and experimental results are in good agreement. Based on the verified models, the design curves showing the effects of parameters on the performance of oxygenators and the guidelines detailing the optimization process are established to determine the optimal design parameters (fiber bundle dimensions and its porosity) under specific system design requirements (blood pressure drop, oxygen pressure/saturation, oxygen/carbon dioxide transfer rates, and priming volume). The results show that the model-based optimization method is promising to derive the optimal parameters in an efficient way and to serve as an intermediate modeling approach prior to complex CFD modeling.
引用
收藏
页数:12
相关论文
共 34 条
[1]   Small intrapulmonary artery lung prototypes - Mathematical modeling of gas transfer [J].
Baskaran, H ;
Nodelman, V ;
Ultman, JS ;
Richard, RB ;
Panol, G ;
High, KM ;
Snider, MT .
ASAIO JOURNAL, 1996, 42 (05) :M597-M603
[2]   Mass and momentum transport in extra-luminal flow (ELF) membrane devices for blood oxygenation [J].
Catapano, G ;
Papenfuss, HD ;
Wodetzki, A ;
Baurmeister, U .
JOURNAL OF MEMBRANE SCIENCE, 2001, 184 (01) :123-135
[3]   Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD [J].
Chen, Zengsheng ;
Jena, Sofen K. ;
Giridharan, Guruprasad A. ;
Sobieski, Michael A. ;
Koenig, Steven C. ;
Slaughter, Mark S. ;
Griffith, Bartley P. ;
Wu, Zhongjun J. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (04) :807-818
[4]   Flow features and device-induced blood trauma in CF-VADs under a pulsatile blood flow condition: A CFD comparative study [J].
Chen, Zengsheng ;
Jena, Sofen K. ;
Giridharan, Guruprasad A. ;
Koenig, Steven C. ;
Slaughter, Mark S. ;
Griffith, Bartley P. ;
Wu, Zhongjun J. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (02)
[5]   Hydrodynamic characteristics of artificial lungs [J].
Dierickx, PW ;
De Somer, F ;
De Wachter, DS ;
Van Nooten, G ;
Verdonck, PR .
ASAIO JOURNAL, 2000, 46 (05) :532-535
[6]   Mass transfer characteristics of artificial lungs [J].
Dierickx, PW ;
De Wachter, DS ;
De Somer, F ;
Van Nooten, G ;
Verdonck, PR .
ASAIO JOURNAL, 2001, 47 (06) :628-633
[7]  
ERGUN S, 1952, CHEM ENG PROG, V48, P89
[8]  
Fletcher E. R, 1983, RESP PHYSL, V51, P167, DOI [10.1016/0034-5687(83)90038-5, DOI 10.1016/0034-5687(83)90038-5]
[9]  
Gage K. L., 2007, THESIS
[10]  
Hang NH, 1997, ASAIO J, V43, pM372