Ultrasound biomicroscopy comparison of ab interno and ab externo scleral fixation of posterior chamber intraocular lenses

被引:28
作者
Kamal, Ahmed M. [1 ]
Hanafy, Mervat [1 ]
Ehsan, Asser [1 ]
Tomerak, Reham H. [1 ]
机构
[1] Cairo Univ, Dept Ophthalmol, Cairo, Egypt
关键词
CAPSULAR SUPPORT; HAPTIC POSITION; IMPLANTATION; ABSENCE; SUTURE;
D O I
10.1016/j.jcrs.2009.01.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PC IOLs) using ultrasound biomicroscopy (UBM) to determine the centration of IOL optic and the position of the haptics in relation to the sulcus. SETTING: Kasr Eleini Hospital, Cairo University, Cairo, Egypt. METHODS: Consecutive patients with aphakia had ab externo or ab interno scleral fixation of a PC IOL. Ultrasound biomicroscopy was used preoperatively to determine whether the eyes were unsuitable for capsule fixation and 3 and 6 months postoperatively, determine the position of the haptics in relation to the ciliary sulcus, and evaluate centration of the optic. RESULTS: Fifteen eyes of 14 patients were studied. Eight patients had ab externo fixation, and 7 had ab interno fixation. The haptics were located in the sulcus in 31% of cases with ab externo fixation and 29% with ab interno fixation. The difference was not statistically significant. CONCLUSION: Ab interno and ab externo scleral fixation, which are both blind procedures, resulted in comparable low rates of sulcus fixation.
引用
收藏
页码:881 / 884
页数:4
相关论文
共 11 条
[2]  
HU BV, 1988, ARCH OPHTHALMOL-CHIC, V106, P416
[3]  
LEWIS JS, 1991, OPHTHALMIC SURG LAS, V22, P692
[4]   LENS GUIDE SUTURE FOR TRANSPORT AND FIXATION IN SECONDARY IOL IMPLANTATION AFTER INTRACAPSULAR EXTRACTION [J].
MALBRAN, ES ;
MALBRAN, E ;
NEGRI, I .
INTERNATIONAL OPHTHALMOLOGY, 1986, 9 (2-3) :151-160
[5]   DETERMINATION OF HAPTIC POSITION OF TRANSSCLERALLY FIXATED POSTERIOR CHAMBER INTRAOCULAR LENSES BY ULTRASOUND BIOMICROSCOPY [J].
PAVLIN, CJ ;
ROOTMAN, D ;
ARSHINOFF, S ;
HARASIEWICZ, K ;
FOSTER, FS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05) :573-577
[6]  
PAVLIN CJ, 1991, OPHTHALMOLOGY, V98, P287
[7]   Ultrasound biomicroscopy of haptic position after transscleral fixation of posterior chamber intraocular lenses [J].
Sewelam, A ;
Ismail, AM ;
El Serogy, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09) :1418-1422
[8]   EXTERNAL TRANSSCLERAL POSTERIOR CHAMBER LENS FIXATION [J].
SHAPIRO, A ;
LEEN, MM .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (12) :1759-1760
[9]  
SPIGELMAN AV, 1988, OPHTHALMIC SURG LAS, V19, P396
[10]  
STARK WJ, 1988, OPHTHALMIC SURG LAS, V19, P240