Pre-Polarized Hydrophobic Conducting Polymer Solid-Contact Ion Selective Electrodes with Improved Potential Reproducibility

被引:83
|
作者
He, Ning [1 ]
Papp, Soma [3 ]
Lindfors, Tom [1 ]
Hofler, Lajos [2 ]
Latonen, Rose-Marie [1 ]
Gyurcsanyi, Robert E. [3 ]
机构
[1] Abo Akad Univ, Fac Sci & Engn, Johan Gadolin Proc Chem Ctr, Analyt Chem Lab, Biskopsgatan 8, FIN-20500 Turku, Finland
[2] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, Szt Gellert Ter 4, H-1111 Budapest, Hungary
[3] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, MTA BME Lendulet Chem Nanosensors Res Grp, Szt Gellert Ter 4, H-1111 Budapest, Hungary
基金
芬兰科学院;
关键词
PLASTICIZED POLY(VINYL CHLORIDE); STATE POTENTIOMETRIC SENSORS; IMPRINTED MESOPOROUS CARBON; ATTENUATED TOTAL-REFLECTION; WATER-UPTAKE; FTIR-ATR; MEMBRANE ELECTRODES; STABILITY; TRANSPORT; FILMS;
D O I
10.1021/acs.analchem.6b04885
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrically conducting polymers (ECPs) are one of the most popular types of materials to interface ion-selective membranes (ISMs) with electron-conducting substrates to construct solid-contact ion-selective electrodes (SCISEs). For optimal ion-to-electron transduction and potential stability, the p-doped ECPs with low oxidation potentials such as PPy need to be generally in their conducting form along with providing a sufficiently hydrophobic interface to counteract the aqueous layer formation. The first criterion requires that the ECPs are in their oxidized state, but the high charge density of this state is detrimental for the prevention of the aqueous layer formation. We offer here a solution to this paradox by implementing a highly hydrophobic perfluorinated anion (perfluorooctanesulfonate, PFOS-) as doping ion by which the oxidized form of the ECP becomes hydrophobic. The proof of concept is shown by using polypyrrole (PPy) films doped with PFOS- (PPy-PFOS) as the solid contact in K(+-)selective SCISEs (KtSCISE). Prior to applying the plasticized poly(vinyl chloride) ISM, the oxidation state of the electrodeposited PPy-PFOS was adjusted by polarization to the known open-circuit potential of the solid contact in 0.1 M KC1. We show that the prepolarization results in a hydrophobic PPy-PFOS film with a water contact angle of 97 5, which effectively prevents the aqueous layer formation under the ISM. Under optimal conditions the K+-SCISEs had a very low standard deviation of E degrees of only 501.0 +/- 0.7 mV that is the best E degrees reproducibility reported for ECP-based SCISEs.
引用
收藏
页码:2598 / 2605
页数:8
相关论文
共 50 条
  • [41] In Situ Ammonium Profiling Using Solid-Contact Ion-Selective Electrodes in Eutrophic Lakes
    Athavale, Rohini
    Kokorite, Ilga
    Dinkel, Christian
    Bakker, Eric
    Wehrli, Bernhard
    Crespo, Gaston A.
    Brand, Andreas
    ANALYTICAL CHEMISTRY, 2015, 87 (24) : 11990 - 11997
  • [42] Ordered mesoporous carbon sphere-based solid-contact ion-selective electrodes
    Jiang, Zidengya
    Xi, Xin
    Qiu, Shi
    Wu, Dongqing
    Tang, Wei
    Guo, Xiaojun
    Su, Yuezeng
    Liu, Ruili
    JOURNAL OF MATERIALS SCIENCE, 2019, 54 (21) : 13674 - 13684
  • [43] Solid-Contact Ion-Selective Electrodes (ISEs) based on Ligand Functionalised Gold Nanoparticles
    Matzeu, Giusy
    Zuliani, Claudio
    Diamond, Dermot
    ELECTROCHIMICA ACTA, 2015, 159 : 158 - 165
  • [44] Solid-contact ion-selective electrodes for aromatic cations based on π-coordinating soft carriers
    Bobacka, J
    Alaviuhkola, T
    Hietapelto, V
    Koskinen, H
    Lewenstam, A
    Lämsä, M
    Pursiainen, J
    Ivaska, A
    TALANTA, 2002, 58 (02) : 341 - 349
  • [45] Redox probe-based amperometric sensing for solid-contact ion-selective electrodes
    Sun, Xiaotong
    Yin, Tanji
    Zhang, Ziping
    Qin, Wei
    TALANTA, 2022, 239
  • [46] Ordered mesoporous carbon sphere-based solid-contact ion-selective electrodes
    Zidengya Jiang
    Xin Xi
    Shi Qiu
    Dongqing Wu
    Wei Tang
    Xiaojun Guo
    Yuezeng Su
    Ruili Liu
    Journal of Materials Science, 2019, 54 : 13674 - 13684
  • [47] Improving the Sensitivity of Solid-Contact Ion-Selective Electrodes by Using Coulometric Signal Transduction
    Han, Tingting
    Mattinen, Ulriika
    Bobacka, Johan
    ACS SENSORS, 2019, 4 (04): : 900 - 906
  • [48] A simple approach for fabricating solid-contact ion-selective electrodes using nanomaterials as transducers
    Liang, Rongning
    Yin, Tanji
    Qin, Wei
    ANALYTICA CHIMICA ACTA, 2015, 853 : 291 - 296
  • [49] Improved Solid-Contact Nitrate Ion Selective Electrodes Based on Multi-Walled Carbon Nanotubes (MWCNTs) as an Ion-to-Electron Transducer
    Hassan, Saad S. M.
    Eldin, Ahmed Galal
    Amr, Abd El-Galil E.
    Al-Omar, Mohamed A.
    Kamel, Ayman H.
    Khalifa, Nagy M.
    SENSORS, 2019, 19 (18)
  • [50] Achieving preeminent stability and reproducibility in an ion-selective electrode for copper ion via introducing a hydrophobic NiCo2S4/PFOA solid-contact
    Ni, Zihui
    Wei, Caixia
    Xu, Ke
    He, Jia
    Tang, Shiyu
    Zhou, Shanbin
    Yang, Jianchun
    Yang, Wenjing
    Zhang, Yunhuai
    Li, Xueming
    MICROCHEMICAL JOURNAL, 2024, 200