Mass spectrometric behavior of anabolic androgenic steroids using gas chromatography coupled to atmospheric pressure chemical ionization source. Part I: Ionization

被引:35
作者
Raro, M. [1 ]
Portoles, T. [1 ]
Sancho, J. V. [1 ]
Pitarch, E. [1 ]
Hernandez, F. [1 ]
Marcos, J. [2 ,3 ]
Ventura, R. [2 ,3 ]
Gomez, C. [2 ]
Segura, J. [2 ,3 ]
Pozo, O. J. [2 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, E-12071 Castellon de La Plana, Spain
[2] Hosp del Mar, Bioanal Res Grp, IMIM, Med Res Inst, Barcelona 08003, Spain
[3] Univ Pompeu Fabra, Dept Expt & Hlth Sci, Barcelona 08003, Spain
来源
JOURNAL OF MASS SPECTROMETRY | 2014年 / 49卷 / 06期
关键词
anabolic androgenic steroids (AAS); atmospheric pressure chemical ionization (APCI); gas chromatography (GC); mass spectrometry (MS); doping control analysis; LIQUID-CHROMATOGRAPHY; HUMAN URINE; SCREENING METHOD; ION-SOURCE; IDENTIFICATION; ADVANTAGES; AGENTS; GC/MS; MS;
D O I
10.1002/jms.3367
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection of anabolic androgenic steroids (AAS) is one of the most important topics in doping control analysis. Gas chromatography coupled to (tandem) mass spectrometry (GC-MS(/MS)) with electron ionization and liquid chromatography coupled to tandem mass spectrometry have been traditionally applied for this purpose. However, both approaches still have important limitations, and, therefore, detection of all AAS is currently afforded by the combination of these strategies. Alternative ionization techniques can minimize these drawbacks and help in the implementation of a single method for the detection of AAS. In the present work, a new atmospheric pressure chemical ionization (APCI) source commercialized for gas chromatography coupled to a quadrupole time-of-flight analyzer has been tested to evaluate the ionization of 60 model AAS. Underivatized and trimethylsylil (TMS)-derivatized compounds have been investigated. The use of GC-APCI-MS allowed for the ionization of all AAS assayed irrespective of their structure. The presence of water in the source as modifier promoted the formation of protonated molecules ([M+H](+)), becoming the base peak of the spectrum for the majority of studied compounds. Under these conditions, [M+H](+), [M+H-H2O]+ and [M+H-2H(2)O]+ for underivatized AAS and [M+H](+), [M+H-TMSOH](+) and [M+H-2.TMSOH](+) for TMS-derivatized AAS were observed as main ions in the spectra. The formed ions preserve the intact steroid skeleton, and, therefore, they might be used as specific precursors in MS/MS-based methods. Additionally, a relationship between the relative abundance of these ions and the AAS structure has been established. This relationship might be useful in the structural elucidation of unknown metabolites. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:509 / 521
页数:13
相关论文
共 36 条
[1]   Enhancement of chemical derivatization of steroids by gas chromatography/mass spectrometry (GC/MS) [J].
Bowden, John A. ;
Colosi, Dominic M. ;
Mora-Montero, Diana C. ;
Garrett, Timothy J. ;
Yost, Richard A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27) :3237-3242
[2]   The application of gas chromatography/atmospheric pressure chemical ionisation time-of-flight mass spectrometry to impurity identification in Pharmaceutical Development [J].
Bristow, Tony ;
Harrison, Mark ;
Sims, Martin .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (11) :1673-1681
[3]   Analytical methods for anti-doping control in sport: anabolic steroids with 4,9,11-triene structure in urine [J].
Brun, Eva M. ;
Puchades, Rosa ;
Maquieira, Angel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (05) :771-783
[4]   Gas Chromatography/Atmospheric Pressure Chemical Ionization-Time of Flight Mass Spectrometry: Analytical Validation and Applicability to Metabolic Profiling [J].
Carrasco-Pancorbo, Alegria ;
Nevedomskaya, Ekaterina ;
Arthen-Engeland, Thomas ;
Zey, Thomas ;
Zurek, Gabriela ;
Baessmann, Carsten ;
Deelder, Andre M. ;
Mayboroda, Oleg A. .
ANALYTICAL CHEMISTRY, 2009, 81 (24) :10071-10079
[5]   A comprehensive procedure based on gas chromatography-isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine [J].
de la Torre, Xavier ;
Colamonici, Cristiana ;
Curcio, Davide ;
Molaioni, Francesco ;
Botre, Francesco .
ANALYTICA CHIMICA ACTA, 2012, 756 :23-29
[6]   Sensitive and robust method for anabolic agents in human urine by gas chromatography-triple quadrupole mass spectrometry [J].
Delgadillo, Miguel A. ;
Garrostas, Lorena ;
Pozo, Oscar J. ;
Ventura, Rosa ;
Velasco, Benjamin ;
Segura, Jordi ;
Marcos, Josep .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 897 :85-89
[7]   Atmospheric pressure gas chromatography with quadrupole time of flight mass spectrometry for simultaneous detection and quantification of polycyclic aromatic hydrocarbons and nitro-polycyclic aromatic hydrocarbons in mosses [J].
Domeno, Celia ;
Canellas, Elena ;
Alfaro, Pilar ;
Rodriguez-Lafuente, Angel ;
Nerin, Cristina .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1252 :146-154
[8]   N-METHYL-N-TRIMETHYLSILYL-TRIFLUOROACETAMIDE A NEW SILYLATING AGENT FROM SERIES OF SILYLATED AMIDES [J].
DONIKE, M .
JOURNAL OF CHROMATOGRAPHY, 1969, 42 (01) :103-&
[9]   Improved ultrasonic-based sample treatment for the screening of anabolic steroids by gas chromatography/mass spectrometry [J].
Galesio, M. ;
Rial-Otero, R. ;
Simal-Gandara, J. ;
de la Torre, X. ;
Botre, F. ;
Capelo-Martinez, J. L. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (16) :2375-2385
[10]   Gas chromatography-atmospheric pressure chemical ionization-time of flight mass spectrometry for profiling of phenolic compounds in extra virgin olive oil [J].
Garcia-Villalba, Rocio ;
Pacchiarotta, Tiziana ;
Carrasco-Pancorbo, Alegria ;
Segura-Carretero, Antonio ;
Fernandez-Gutierrez, Alberto ;
Deelder, Andre M. ;
Mayboroda, Oleg A. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (07) :959-971