DEVELOPMENT OF A DISPOSABLE IMPEDANCE BIOSENSOR AND ITS APPLICATION FOR DETERMINATION OF ESCHERICHIA COLI O157:H7

被引:0
作者
Wang, Y. X. [1 ]
Ye, Z. Z. [1 ]
Ying, Y. B. [1 ]
机构
[1] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Disposable biosensor; Escherichia coli O157:H7; Gold nanoparticles; Graphene; Impedance; FOODBORNE PATHOGENIC BACTERIA; GLASSY-CARBON ELECTRODE; GRAPHENE OXIDE SHEETS; GOLD NANOPARTICLES; RAPID DETECTION; ELECTROCHEMICAL IMMUNOSENSOR; CARCINOEMBRYONIC ANTIGEN; SENSITIVE DETECTION; O157-H7; ANTIBODY;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The development of cost-effective, robust, and rugged biosensing devices is of great interest for point-of-care testing and on-site monitoring. Here we report a facile approach to building high-performance disposable impedance biosensors for sensitive and selective determination of Escherichia coli O157:H7. Gold nanoparticles and graphene modified screen-printed carbon as the electrode substrate were employed in this impedance biosensor. The immobilization of anti-E. coli O157:H7 antibodies on the electrode surface was performed by simple physical adsorption. Electrochemical impedance spectroscopy was used to detect E. coli O157:H7 captured on the disposable biosensor. Results showed that the developed immunosensor possesses excellent sensing performance, such as wide linear range (1.5 x 10(3) to 1.5 x 10(7) cfu mL(-1)), low detection limit (1.5 x 10(3) cfu mL(-1)), and excellent specificity (no significant interference from E. coli DH 5 alpha, Staphylococcus aureus, or Listeria monocytogenes). The strategy of structurally integrating metal nanomaterials, graphene, and screen-printed electrodes provides new insight into the design of disposable and high-performance immunosensors for routine sensing applications.
引用
收藏
页码:585 / 592
页数:8
相关论文
共 50 条
  • [21] Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157:H7
    Wang, Yixian
    Ping, Jianfeng
    Ye, Zunzhong
    Wu, Jian
    Ying, Yibin
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 492 - 498
  • [22] Determination of the Infection Dynamics of Escherichia coli O157:H7 by Bacteriophage ΦV10
    Oats, Michael F.
    Coronel-Aguilera, Claudia P.
    Applegate, Bruce M.
    Csonka, Laszlo N.
    Bhunia, Arun K.
    Gehring, Andrew G.
    Paoli, George C.
    FOODS, 2025, 14 (04)
  • [23] Conductometric Immunosensor for Escherichia coli O157:H7 Detection Based on Polyaniline/Zinc Oxide (PANI/ZnO) Nanocomposite
    Mutlaq, Sawsan
    Albiss, Borhan
    Al-Nabulsi, Anas A.
    Jaradat, Ziad W.
    Olaimat, Amin N.
    Khalifeh, Mohammad S.
    Osaili, Tareq
    Ayyash, Mutamed M.
    Holley, Richard A.
    POLYMERS, 2021, 13 (19)
  • [24] Electrochemical DNA Biosensor Based on Graphene Oxide-Chitosan Hybrid Nanocomposites for Detection of Escherichia Coli O157:H7
    Xu, Shichao
    Zhang, Yiyi
    Dong, Kai
    Wen, Junnan
    Zheng, Chunming
    Zhao, Shihuai
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3443 - 3458
  • [25] The Impact of Biofilm Growth on Transport of Escherichia coli O157:H7 in Sand
    Wang, Aimin
    Lin, Bin
    Sleep, Brent E.
    Liss, Steven N.
    GROUND WATER, 2011, 49 (01) : 20 - 31
  • [26] Selection of Antibiotics in Detection Procedure of Escherichia coli O157:H7 in Vegetables
    Hoang, Hoang A.
    Nhung, Nguyen T. T.
    INTERNATIONAL CONFERENCE ON CHEMICAL ENGINEERING, FOOD AND BIOTECHNOLOGY (ICCFB2017), 2017, 1878
  • [27] Inhibition of oregano essential oil and EDTA on Escherichia coli O157:H7
    Skandamis, P
    Koutsoumanis, K
    Fasseas, K
    Nychas, GJE
    ITALIAN JOURNAL OF FOOD SCIENCE, 2001, 13 (01) : 65 - 75
  • [28] Specific and targeted detection of viable Escherichia coli O157:H7 using a sensitive and reusable impedance biosensor with dose and time response studies
    Dweik, Majed
    Stringer, R. Cody
    Dastider, Shibajyoti Ghosh
    Wu, Yifan
    Almasri, Mahmoud
    Barizuddin, Syed
    TALANTA, 2012, 94 : 84 - 89
  • [29] Carboxylation of Porous Pseudo-carbon Paste Electrode and Its Application to Detection of Escherichia coli O157: H7
    Xu Li-Jian
    Du Jing-Jing
    Deng Yan
    Li Zhi-Yang
    Xu Chun-Xiang
    He Nong-Yue
    Wang Hua
    Shi Zhi-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (09) : 1261 - 1266
  • [30] Recent Progress on the Electrochemical Biosensing of Escherichia coli O157:H7: Material and Methods Overview
    Razmi, Nasrin
    Hasanzadeh, Mohammad
    Willander, Magnus
    Nur, Omer
    BIOSENSORS-BASEL, 2020, 10 (05):