Improved operation of the Michelson interferometer electron cyclotron emission diagnostic on DIII-D

被引:31
|
作者
Austin, ME
Ellis, RF
Doane, JL
James, RA
机构
[1] UNIV MARYLAND,INST PLASMA RES,COLLEGE PK,MD 20742
[2] LAWRENCE LIVERMORE NATL LAB,LIVERMORE,CA 94551
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1997年 / 68卷 / 01期
关键词
D O I
10.1063/1.1147612
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The measurement of accurate temperature profiles is critical for transport analysis and equilibrium reconstruction in the DIII-D tokamak. Recent refinements in the Michelson interferometer diagnostic have produced more precise electron temperature measurements from electron cyclotron emission and made them available for a wider range of discharge conditions. Replacement of a lens-relay with a low-loss corrugated waveguide transmission system resulted in an increase in throughput of 6 dB and a reduction of calibration error from 15% to 5%. The waveguide exhibits a small polarization scrambling fraction of 0.05 at the quarter-wavelength frequency and very stable transmission characteristics over time. Further reduction in error was realized through special signal processing of the calibration and plasma interferograms. (C) 1997 American Institute of Physics.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 50 条
  • [1] TFTR MICHELSON INTERFEROMETER ELECTRON-CYCLOTRON EMISSION DIAGNOSTIC
    STAUFFER, FJ
    BOYD, DA
    CUTLER, RC
    MCCARTHY, MP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 925 - 927
  • [2] Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak
    DeGrandchamp, G. H.
    Thome, K. E.
    Heidbrink, W. W.
    Holmes, I.
    Pinsker, R. I.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (03):
  • [3] VERTICAL-VIEWING ELECTRON-CYCLOTRON EMISSION DIAGNOSTIC FOR THE DIII-D TOKAMAK
    JAMES, R
    JANZ, S
    ELLIS, R
    BOYD, D
    LOHR, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1611 - 1613
  • [4] Electron cyclotron emission radiometer upgrade on the DIII-D tokamak
    Austin, ME
    Lohr, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1457 - 1459
  • [5] Electron cyclotron heating on DIII-D
    Prater, R
    Petty, CC
    FUSION SCIENCE AND TECHNOLOGY, 2005, 48 (02) : 1141 - 1148
  • [6] A New and Highly Flexible Dual Array Electron Cyclotron Emission Imaging Diagnostic for DIII-D
    Tobias, B.
    Domier, C. W.
    Donne, A. J. H.
    Jaspers, R. J. E.
    Kong, X.
    Liang, T.
    Luhmann, N. C., Jr.
    Smith, M.
    Nazikian, R.
    Park, H. K.
    APMC: 2009 ASIA PACIFIC MICROWAVE CONFERENCE, VOLS 1-5, 2009, : 210 - +
  • [7] Improved cross-calibration of Thomson scattering and electron cyclotron emission with ECH on DIII-D
    Brookman, M. W.
    Austin, M. E.
    McLean, A. G.
    Carlstrom, T. N.
    Hyatt, A. W.
    Lohr, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [8] Electron cyclotron wave experiments on DIII-D
    Petty, CC
    deGrassie, JS
    Harvey, RW
    Lin-Liu, YR
    Lohr, JM
    Luce, TC
    Makowski, MA
    Omelchenko, YA
    Prater, R
    RADIO FREQUENCY POWER IN PLASMAS, 2001, 595 : 275 - 281
  • [9] Electron cyclotron current drive in DIII-D
    Luce, TC
    Lin-Liu, YR
    Harvey, RW
    Giruzzi, G
    Lohr, JM
    Petty, CC
    Politzer, PA
    Prater, R
    Rice, BW
    RADIO FREQUENCY POWER IN PLASMAS, 1999, 485 : 213 - 220
  • [10] A Michelson Interferometer for Electron Cyclotron Emission Measurements on EAST
    刘永
    Stefan SCHMUCK
    赵海林
    John FESSEY
    Paul TRIMBLE
    刘祥
    朱则英
    臧庆
    胡立群
    Plasma Science and Technology, 2016, 18 (12) : 1148 - 1154