Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

被引:5
作者
Song, Chang-Ho [1 ,2 ]
Yeom, Han-Gyeol [3 ]
Kim, Jo-Eun [1 ,2 ]
Huh, Kyung-Hoe [1 ,2 ]
Yi, Won-Jin [1 ,2 ]
Heo, Min-Suk [1 ,2 ]
Lee, Sam-Sun [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
[3] Wonkwang Univ, Daejeon Dent Hosp, Coll Dent, Dept Oral & Maxillofacial Radiol, 77 Dunsan Ro, Daejeon 35233, South Korea
基金
新加坡国家研究基金会;
关键词
Radiation Exposure; Cone-Beam Computed Tomography; Diagnostic X-Ray; Quality Control;
D O I
10.5624/isd.20220129
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 21 条