Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study

被引:224
作者
Vignaux, Laurence [1 ]
Vargas, Frederic [2 ,3 ,4 ]
Roeseler, Jean [5 ]
Tassaux, Didier [1 ]
Thille, Arnaud W. [2 ,3 ,4 ]
Kossowsky, Michel P. [6 ]
Brochard, Laurent [2 ,3 ,4 ]
Jolliet, Philippe [1 ]
机构
[1] Hop Cantonal Univ Geneva, Serv Soins Intensifs, CH-1211 Geneva 14, Switzerland
[2] Ctr Hosp Albert Chenevier Henri Mondor, AP HP, Creteil, France
[3] Hop Henri Mondor, INSERM, U 841, F-94010 Creteil, France
[4] Univ Paris 12, Creteil, France
[5] Clin Univ St Luc, Serv Soins Intensifs, B-1200 Brussels, Belgium
[6] Hop Cantonal Univ Geneva, Serv Med Premier Recours, CH-1211 Geneva 14, Switzerland
关键词
Noninvasive ventilation; Mechanical ventilation; Patient-ventilator interaction; Asynchrony; PRESSURE SUPPORT VENTILATION; INSPIRATORY EFFORT; PRESSURIZATION; BENCH; MODES; WORK;
D O I
10.1007/s00134-009-1416-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To determine the prevalence of patient-ventilator asynchrony in patients receiving non-invasive ventilation (NIV) for acute respiratory failure. Prospective multicenter observation study. Intensive care units in three university hospitals. Patients consecutively admitted to ICU were included. NIV, performed with an ICU ventilator, was set by the clinician. Airway pressure, flow, and surface diaphragmatic electromyography were recorded continuously for 30 min. Asynchrony events and the asynchrony index (AI) were determined from visual inspection of the recordings and clinical observation. A total of 60 patients were included, 55% of whom were hypercapnic. Auto-triggering was present in 8 (13%) patients, double triggering in 9 (15%), ineffective breaths in 8 (13%), premature cycling 7 (12%) and late cycling in 14 (23%). An AI > 10%, indicating severe asynchrony, was present in 26 patients (43%), whose median (25-75 IQR) AI was 26 (15-54%). A significant correlation was found between the magnitude of leaks and the number of ineffective breaths and severity of delayed cycling. Multivariate analysis indicated that the level of pressure support and the magnitude of leaks were weakly, albeit significantly, associated with an AI > 10%. Patient comfort scale was higher in pts with an AI < 10%. Patient-ventilator asynchrony is common in patients receiving NIV for acute respiratory failure. Our results suggest that leaks play a major role in generating patient-ventilator asynchrony and discomfort, and point the way to further research to determine if ventilator functions designed to cope with leaks can reduce asynchrony in the clinical setting.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 29 条
[1]   Predictors of failure of noninvasive positive pressure ventilation in patients with acute hypoxemic respiratory failure: a multi-center study [J].
Antonelli, M ;
Conti, G ;
Moro, ML ;
Esquinas, A ;
Gonzalez-Diaz, G ;
Confalonieri, M ;
Pelaia, P ;
Principi, T ;
Gregoretti, C ;
Beltrame, F ;
Pennisi, MA ;
Arcangeli, A ;
Proietti, R ;
Passariello, M ;
Meduri, GU .
INTENSIVE CARE MEDICINE, 2001, 27 (11) :1718-1728
[2]   AIRWAY LEAK SIZE IN NEONATES AND AUTOCYCLING OF 3 FLOW-TRIGGERED VENTILATORS [J].
BERNSTEIN, G ;
KNODEL, E ;
HELDT, GP .
CRITICAL CARE MEDICINE, 1995, 23 (10) :1739-1744
[3]   NONINVASIVE VENTILATION FOR ACUTE EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
BROCHARD, L ;
MANCEBO, J ;
WYSOCKI, M ;
LOFASO, F ;
CONTI, G ;
RAUSS, A ;
SIMONNEAU, G ;
BENITO, S ;
GASPARETTO, A ;
LEMAIRE, F ;
ISABEY, D ;
HARF, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (13) :817-822
[4]   Patient-ventilator asynchrony during noninvasive ventilation: the role of expiratory trigger [J].
Calderini, E ;
Confalonieri, M ;
Puccio, PG ;
Francavilla, N ;
Stella, L ;
Gregoretti, C .
INTENSIVE CARE MEDICINE, 1999, 25 (07) :662-667
[5]   Noninvasive versus conventional mechanical ventilation - An epidemiologic survey [J].
Carlucci, A ;
Richard, JC ;
Wysocki, M ;
Lepage, E ;
Brochard, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (04) :874-880
[6]   Increased use of noninvasive ventilation in French intensive care units [J].
Demoule, Alexandre ;
Girou, Emmanuelle ;
Richard, Jean-Christophe ;
Taille, Solenne ;
Brochard, Laurent .
INTENSIVE CARE MEDICINE, 2006, 32 (11) :1747-1755
[7]   Performance of ventilators for noninvasive positive-pressure ventilation in children [J].
Fauroux, B. ;
Leroux, K. ;
Desmarais, G. ;
Isabey, D. ;
Clement, A. ;
Lofaso, F. ;
Louis, B. .
EUROPEAN RESPIRATORY JOURNAL, 2008, 31 (06) :1300-1307
[8]   Noninvasive respiratory ventilation in severe hypoxemic failure - A randomized clinical trial [J].
Ferrer, M ;
Esquinas, A ;
Leon, M ;
Gonzalez, G ;
Alarcon, A ;
Torres, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 168 (12) :1438-1444
[9]   Noninvasive ventilation in acute respiratory failure [J].
Hill, Nicholas S. ;
Brennan, John ;
Garpestad, Erik ;
Nava, Stefano .
CRITICAL CARE MEDICINE, 2007, 35 (10) :2402-2407
[10]   Patient-ventilator interaction [J].
Kondili, E ;
Prinianakis, G ;
Georgopoulos, D .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (01) :106-119