Testing of complementarity of PDA and MS detectors using chromatographic fingerprinting of genuine and counterfeit samples containing sildenafil citrate

被引:9
作者
Custers, Deborah [1 ,2 ]
Krakowska, Barbara [3 ]
De Beer, Jacques O. [1 ]
Courselle, Patricia [1 ]
Daszykowski, Michal [3 ]
Apers, Sandra [2 ]
Deconinck, Eric [1 ]
机构
[1] Sci Inst Publ Hlth WIV ISP, Sect Med Prod, Div Food Med & Consumer Safety, J Wytsmanstr 14, B-1050 Brussels, Belgium
[2] Univ Antwerp, Dept Pharmaceut Sci, Res Grp NatuRA Nat Prod & Food Res & Anal, Univ Pl 1, B-2610 Antwerp, Belgium
[3] Silesian Univ, Inst Chem, 9 Szkolna St, PL-40006 Katowice, Poland
关键词
Counterfeit medicines; Viagra (R); Chemometrics; High-performance liquid chromatography; Photodiode array detection; Mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SYNTHETIC PHOSPHODIESTERASE-5 INHIBITORS; ERECTILE DYSFUNCTION DRUGS; DIETARY-SUPPLEMENTS; QUANTITATIVE-ANALYSIS; IDENTIFICATION; ANALOG; MEDICINES; TADALAFIL; THIOSILDENAFIL;
D O I
10.1007/s00216-015-9275-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Counterfeit medicines are a global threat to public health. High amounts enter the European market, which is why characterization of these products is a very important issue. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) and high-performance liquid chromatography-mass spectrometry (HPLC-MS) method were developed for the analysis of genuine ViagraA (R), generic products of ViagraA (R), and counterfeit samples in order to obtain different types of fingerprints. These data were included in the chemometric data analysis, aiming to test whether PDA and MS are complementary detection techniques. The MS data comprise both MS1 and MS2 fingerprints; the PDA data consist of fingerprints measured at three different wavelengths, i.e., 254, 270, and 290 nm, and all possible combinations of these wavelengths. First, it was verified if both groups of fingerprints can discriminate between genuine, generic, and counterfeit medicines separately; next, it was studied if the obtained results could be ameliorated by combining both fingerprint types. This data analysis showed that MS1 does not provide suitable classification models since several genuines and generics are classified as counterfeits and vice versa. However, when analyzing the MS1_MS2 data in combination with partial least squares-discriminant analysis (PLS-DA), a perfect discrimination was obtained. When only using data measured at 254 nm, good classification models can be obtained by k nearest neighbors (kNN) and soft independent modelling of class analogy (SIMCA), which might be interesting for the characterization of counterfeit drugs in developing countries. However, in general, the combination of PDA and MS data (254 nm_MS1) is preferred due to less classification errors between the genuines/generics and counterfeits compared to PDA and MS data separately.
引用
收藏
页码:1643 / 1656
页数:14
相关论文
共 48 条
  • [31] Aligning of single and multiple wavelength chromatographic profiles for chemometric data analysis using correlation optimised warping
    Nielsen, NPV
    Carstensen, JM
    Smedsgaard, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) : 17 - 35
  • [32] Nunes C., 2013, SOFT INDEPENDENT MOD
  • [33] Nunes C, 2011, PARTIAL LEAST SQUARE
  • [34] Profiling counterfeit Cialis, Viagra and analogs by UPLC-MS
    Ortiz, Rafael S.
    Mariotti, Kristiane de Cassia
    Holzschuh, Maribete H.
    Romao, Wanderson
    Limberger, Renata P.
    Mayorga, Paulo
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2013, 229 (1-3) : 13 - 20
  • [35] Fingerprinting of sildenafil citrate and tadalafil tablets in pharmaceutical formulations via X-ray fluorescence (XRF) spectrometry
    Ortiz, Rafael S.
    Mariotti, Kristiane C.
    Schwab, Nicolas V.
    Sabin, Guilherme P.
    Rocha, Werickson F. C.
    de Castro, Eustaquio V. R.
    Limberger, Renata P.
    Mayorga, Paulo
    Bueno, Maria Izabel M. S.
    Romao, Wanderson
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 58 : 7 - 11
  • [36] Quantitative Analysis of Sildenafil and Tadalafil in Various Fake Drugs Recently Distributed in Korea
    Park, Meejung
    Ahn, Suyoun
    [J]. JOURNAL OF FORENSIC SCIENCES, 2012, 57 (06) : 1637 - 1640
  • [37] Development and validation of a ultra-high-performance liquid chromatography-UV method for the detection and quantification of erectile dysfunction drugs and some of their analogues found in counterfeit medicines
    Sacre, Pierre-Yves
    Deconinck, Eric
    Chiap, Patrice
    Crommen, Jacques
    Mansion, Francois
    Rozet, Eric
    Courselle, Patricia
    De Beer, Jacques O.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (37) : 6439 - 6447
  • [38] Impurity fingerprints for the identification of counterfeit medicines-A feasibility study
    Sacre, Pierre-Yves
    Deconinck, Eric
    Daszykowski, Michal
    Courselle, Patricia
    Vancauwenberghe, Roy
    Chiap, Patrice
    Crommen, Jacques
    De Beer, Jacques O.
    [J]. ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 224 - 231
  • [39] Screening of Indian aphrodisiac ayurvedic/herbal healthcare products for adulteration with sildenafil, tadalafil and/or vardenafil using LC/PDA and extracted ion LC-MS/TOF
    Savaliya, Akash A.
    Shah, Ravi P.
    Prasad, Bhagwat
    Singh, Saranjit
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (03) : 406 - 409
  • [40] Magnetic solid-phase extraction based on methylcellulose coated-Fe3O4-SiO2-phenyl for HPLC-DAD analysis of sildenafil and its metabolite in biological samples
    Tang, Minqiong
    Wang, Qing
    Jiang, Ming
    Xu, Li
    Shi, Zhi-Guo
    Zhang, Ting
    Liu, Yan
    [J]. TALANTA, 2014, 130 : 427 - 432