Testing of complementarity of PDA and MS detectors using chromatographic fingerprinting of genuine and counterfeit samples containing sildenafil citrate

被引:9
作者
Custers, Deborah [1 ,2 ]
Krakowska, Barbara [3 ]
De Beer, Jacques O. [1 ]
Courselle, Patricia [1 ]
Daszykowski, Michal [3 ]
Apers, Sandra [2 ]
Deconinck, Eric [1 ]
机构
[1] Sci Inst Publ Hlth WIV ISP, Sect Med Prod, Div Food Med & Consumer Safety, J Wytsmanstr 14, B-1050 Brussels, Belgium
[2] Univ Antwerp, Dept Pharmaceut Sci, Res Grp NatuRA Nat Prod & Food Res & Anal, Univ Pl 1, B-2610 Antwerp, Belgium
[3] Silesian Univ, Inst Chem, 9 Szkolna St, PL-40006 Katowice, Poland
关键词
Counterfeit medicines; Viagra (R); Chemometrics; High-performance liquid chromatography; Photodiode array detection; Mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SYNTHETIC PHOSPHODIESTERASE-5 INHIBITORS; ERECTILE DYSFUNCTION DRUGS; DIETARY-SUPPLEMENTS; QUANTITATIVE-ANALYSIS; IDENTIFICATION; ANALOG; MEDICINES; TADALAFIL; THIOSILDENAFIL;
D O I
10.1007/s00216-015-9275-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Counterfeit medicines are a global threat to public health. High amounts enter the European market, which is why characterization of these products is a very important issue. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) and high-performance liquid chromatography-mass spectrometry (HPLC-MS) method were developed for the analysis of genuine ViagraA (R), generic products of ViagraA (R), and counterfeit samples in order to obtain different types of fingerprints. These data were included in the chemometric data analysis, aiming to test whether PDA and MS are complementary detection techniques. The MS data comprise both MS1 and MS2 fingerprints; the PDA data consist of fingerprints measured at three different wavelengths, i.e., 254, 270, and 290 nm, and all possible combinations of these wavelengths. First, it was verified if both groups of fingerprints can discriminate between genuine, generic, and counterfeit medicines separately; next, it was studied if the obtained results could be ameliorated by combining both fingerprint types. This data analysis showed that MS1 does not provide suitable classification models since several genuines and generics are classified as counterfeits and vice versa. However, when analyzing the MS1_MS2 data in combination with partial least squares-discriminant analysis (PLS-DA), a perfect discrimination was obtained. When only using data measured at 254 nm, good classification models can be obtained by k nearest neighbors (kNN) and soft independent modelling of class analogy (SIMCA), which might be interesting for the characterization of counterfeit drugs in developing countries. However, in general, the combination of PDA and MS data (254 nm_MS1) is preferred due to less classification errors between the genuines/generics and counterfeits compared to PDA and MS data separately.
引用
收藏
页码:1643 / 1656
页数:14
相关论文
共 48 条
  • [1] Analysis of herbal dietary supplements for sexual performance enhancement: First characterization of propoxyphenyl-thiohydroxyhomosildenafil and identification of sildenafil, thiosildenafil, phentolamine and tetrahydropalmatine as adulterants
    Balayssac, Stephane
    Gilard, Veronique
    Zedde, Chantal
    Martino, Robert
    Malet-Martino, Myriam
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 63 : 135 - 150
  • [2] Headspace-gas chromatographic fingerprints to discriminate and classify counterfeit medicines
    Custers, D.
    Canfyn, M.
    Courselle, P.
    De Beer, J. O.
    Apers, S.
    Deconinck, E.
    [J]. TALANTA, 2014, 123 : 78 - 88
  • [3] Custers D, 2014, J PHARM BIOMED ANAL, V13
  • [4] Custers D, 2015, DRUG TEST ANAL, V28
  • [5] Target selection for alignment of chromatographic signals obtained using monochannel detectors
    Daszykowski, M.
    Walczak, B.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) : 1 - 11
  • [6] Automated alignment of one-dimensional chromatographic fingerprints
    Daszykowski, M.
    Heyden, Y. Vander
    Boucon, C.
    Walczak, B.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (40) : 6127 - 6133
  • [7] Representative subset selection
    Daszykowski, M
    Walczak, B
    Massart, DL
    [J]. ANALYTICA CHIMICA ACTA, 2002, 468 (01) : 91 - 103
  • [8] High performance liquid chromatography-diode array and electrospray-mass spectrometry analysis of vardenafil, sildenafil, tadalafil, testosterone and local anesthetics in cosmetic creams sold on the Internet web sites
    De Orsi, Daniela
    Pellegrini, Manuela
    Marchei, Emilia
    Nebuloni, Paolo
    Gallinella, Bruno
    Scaravelli, Giulia
    Martufi, Alessio
    Gagliardi, Luigi
    Pichini, Simona
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (03) : 362 - 369
  • [9] Detection of whitening agents in illegal cosmetics using attenuated total reflectance-infrared spectroscopy
    Deconinck, E.
    Bothy, J. L.
    Desmedt, B.
    Courselle, P.
    De Beer, J. O.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 178 - 185
  • [10] Evaluation of the residual solvent content of counterfeit tablets and capsules
    Deconinck, E.
    Canfyn, M.
    Sacre, P. -Y.
    Courselle, P.
    De Beer, J. O.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 81-82 : 80 - 88