Reliability of measurements on lateral ankle radiographs

被引:13
作者
Guo, Changjun [1 ,2 ,3 ]
Zhu, Yuan [2 ]
Hu, Mu [1 ]
Deng, Lianfu [3 ]
Xu, Xiangyang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Rui Jin Hosp North, Dept Orthopaed, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Rui Jin Hosp, Dept Orthopaed, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Inst Traumatol & Orthopaed, Shanghai Key Lab Prevent & Treatment Bone & Joint, Rui Jin Hosp,Sch Med, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Ankle; Lateral radiographs; Interobserver study; Reliability; OSTEOARTHRITIS; HINDFOOT; FRACTURES;
D O I
10.1186/s12891-016-1150-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aims of our study were to evaluate the validation of measurement of weight-bearing lateral radiographs. Two hypotheses were tested: the measurements on the lateral radiographs are reliable, and a theoretical limit could be identified when a surgeon can "eyeball" an incongruous ankle joint on lateral radiographs. Methods: To test the first hypothesis, 3 experienced ankle surgeons evaluated 50 normal weight-bearing lateral radiographs of patients. The measurements assessed were the tibial lateral surface angle (TLS), the distance from the center of the talar joint circle to the longitudinal axis of the tibia (x) and the displacement from the center of the talar articular joint circle to the center of the distal tibia articular joint circle (d). To test the second hypothesis, we used CAD software to create schematic diagrams on which lateral radiographs of the ankle joint were not parallel (d = 1, 2, 3, 4 mm). Five experienced ankle surgeons were asked to judge whether the ankle articular surfaces were parallel. Intraobserver reliability was determined using the intraclass correlation coefficients (ICCs) and interobserver agreement by the Kendall coefficient of concordance. Results: First, the intraobserver reliability was high (Cronbach's alpha > 0.80) with regard to radiographic measurements according to the ICC. Significant interobserver disagreement was found (Kendall tauB, p < 0.01) using the Kendall concordance coefficient. Second, when the d-value was 4 mm, all the observers identified the incongruous ankle joint at two separate times. Conclusions: Consultation with experienced foot and ankle surgeons and precise definitions for lateral measurement assessments do not guarantee a high level of agreement. Surgeons can observe an incongruous ankle joint on lateral radiographs when the d-value is 4 mm.
引用
收藏
页数:8
相关论文
共 18 条
[11]  
Mont M A, 1992, J Orthop Trauma, V6, P352, DOI 10.1097/00005131-199209000-00014
[12]   Radiographic measurements do not predict syndesmotic injury in ankle fractures - An MRI study [J].
Nielson, JH ;
Gardner, MJ ;
Peterson, MGE ;
Sallis, JG ;
Potter, HG ;
Helfet, DL ;
Lorich, DG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :216-221
[13]  
Pagenstert G, 2009, OPER ORTHOPADE TRAUM, V21, P77, DOI 10.1007/s00064-009-1607-9
[14]   CHANGES IN TIBIOTALAR AREA OF CONTACT CAUSED BY LATERAL TALAR SHIFT [J].
RAMSEY, PL ;
HAMILTON, W .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (03) :356-357
[15]   Arthroscopy-assisted repair of latent syndesmotic instability of the ankle [J].
Schuberth, John M. ;
Jennings, Meagan M. ;
Lau, Alex C. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (08) :868-874
[16]   Radiographic Evaluation of the Normal Distal Tibiofibular Syndesmosis [J].
Shah, Apurva S. ;
Kadakia, Anish R. ;
Tan, Giselle J. ;
Karadsheh, Mark S. ;
Wolter, Troy D. ;
Sabb, Brian .
FOOT & ANKLE INTERNATIONAL, 2012, 33 (10) :870-876
[17]   Etiology of Ankle Osteoarthritis [J].
Valderrabano, Victor ;
Horisberger, Monika ;
Russell, Iain ;
Dougall, Hugh ;
Hintermann, Beat .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (07) :1800-1806
[18]  
WEBER BG, 1985, CLIN ORTHOP RELAT R, P61