Development of an FIA system with amperometric detection for determination of bentazone in estuarine waters

被引:14
作者
Cerejeira, RPAG
Delerue-Matos, C
Vaz, MCVF
机构
[1] 4200–072 Porto,
[2] Portugal,undefined
关键词
amperometry; bentazone; FIA system; herbicides; estuarine waters;
D O I
10.1007/s00216-002-1344-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 muL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min(-1). Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10(-6) to 5.0x10(-5) mol L-1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h(-1). The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.
引用
收藏
页码:295 / 298
页数:4
相关论文
共 21 条
[1]  
AKERBLOM M, 1984, J ASSOC OFF ANA CHEM, V67, P653
[2]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[4]   ONLINE AND OFF-LINE SAMPLE PREPARATION OF ACIDIC HERBICIDES AND BENTAZONE TRANSFORMATION PRODUCTS IN ESTUARINE WATERS [J].
CHIRON, S ;
MARTINEZ, E ;
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (02) :283-293
[5]   Pressurized fluid extraction of nonpolar pesticides and polar herbicides using in situ derivatization [J].
David, MD ;
Campbell, S ;
Li, QX .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3665-3670
[6]   PREPARATION OF UNIVERSAL BUFFER WITH IONIC-STRENGTH 0.3M [J].
FERNANDEZ, CM ;
MARTIN, VC .
TALANTA, 1977, 24 (12) :747-748
[7]   Electrochemical oxidation of bentazon at a glassy carbon electrode - Application to the determination of a commercial herbicide [J].
Garrido, EM ;
Lima, JLC ;
Delerue-Matos, CM ;
Brett, AMO .
TALANTA, 1998, 46 (05) :1131-1135
[8]  
GARRIDO EM, 1999, PORTUGALIAE ELECTROC, V17, P313
[9]   On-line trace level determination of polar organic microcontaminants in water using various pre-column analytical column liquid chromatographic techniques with ultraviolet absorbance and mass spectrometric detection [J].
Hogenboom, AC ;
Jagt, I ;
Vreuls, RJJ ;
Brinkman, UAT .
ANALYST, 1997, 122 (11) :1371-1377
[10]   Application of liquid chromatography with mass spectrometry combined with photodiode array detection and tandem mass spectrometry for monitoring pesticides in surface waters [J].
Jeannot, R ;
Sabik, H ;
Sauvard, E ;
Genin, E .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) :51-71