Flush-mounted probe diagnostics for argon glow discharge plasma

被引:3
|
作者
Xu, Liang [1 ]
Cao, Jinxiang [1 ]
Liu, Yu [1 ]
Wang, Jian [1 ]
Du, Yinchang [1 ]
Zheng, Zhe [1 ]
Zhang, Xiao [1 ]
Wang, Pi [1 ]
Zhang, Jin [2 ]
Li, Xiao [2 ]
Qin, Yongqiang [2 ]
Zhao, Liang [2 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China
[2] Sci & Technol Space Phys Lab, Beijing 100076, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 09期
关键词
HYPERSONIC IONIZED FLOWS; ELECTROSTATIC PROBES; BOUNDARY-LAYER; LANGMUIR PROBE;
D O I
10.1063/1.4895644
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison is made between plasma parameters measured by a flush-mounted probe (FP) and a cylindrical probe (CP) in argon glow discharge plasma. Parameters compared include the space potential, the plasma density, and the effective electron temperature. It is found that the ion density determined by the FP agrees well with the electron density determined by the CP in the quasi-neutral plasma to better than 10%. Moreover, the space potential and effective electron temperature calculated from electron energy distribution function measured by the FP is consistent with that measured by the CP over the operated discharge current and pressure ranges. These results present the FP can be used as a reliable diagnostic tool in the stable laboratory plasma and also be anticipated to be applied in other complicated plasmas, such as tokamaks, the region of boundary-layer, and so on. (c) 2014 AIP Publishing LLC.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] SPECTROSCOPY AND PROBE DIAGNOSTICS OF DC SPHERICAL GLOW DISCHARGE
    Zhovtyansky, V. A.
    Nazarenko, V. G.
    Syrotyuk, R. P.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2016, (06): : 302 - 305
  • [33] Flush-Mounted Telemetry Antenna Design for a Sounding Rocket Competition
    Ribeiro Filho, P. C.
    Tinoco-S, A. F.
    Nascimento, D. C.
    Lacava, J. C. da S.
    2013 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2013, : 2173 - 2174
  • [34] FLUSH-MOUNTED HOT FILM ANEMOMETER ACCURACY IN PULSATILE FLOW
    NANDY, S
    TARBELL, JM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (03): : 228 - 231
  • [35] FLUSH-MOUNTED PRESSURE TRANSDUCER AS A UNIT OF AN ACOUSTIC HOMING SYSTEM
    MAIDANIK, G
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 47 (1P1): : 123 - &
  • [36] A Flush-mounted Resonant Ice detection sensor with High Sensitivity
    Shi, Qiang
    Wang, Junbo
    Chen, Deyong
    Shang, Yanlong
    MICRO-NANO TECHNOLOGY XIII, 2012, 503 : 81 - 86
  • [37] FLUSH-MOUNTED PROBES IN THE DIVERTOR PLATES OF TOKAMAK DE VARENNES
    GUNN, JP
    BOUCHER, C
    STANSFIELD, BL
    SAVOIE, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 154 - 159
  • [38] SHEATH-CONVECTION EFFECTS WITH FLUSH-MOUNTED ELECTROSTATIC PROBES
    CLEMENTS, RM
    SMY, PR
    CANADIAN JOURNAL OF PHYSICS, 1971, 49 (20) : 2540 - &
  • [39] The influence of magnetization strength on the sheath: Implications for flush-mounted probes
    Gunn, JP
    PHYSICS OF PLASMAS, 1997, 4 (12) : 4435 - 4446
  • [40] INSTANTANEOUS PROBE MEASUREMENTS OF TRAVELING STRIATIONS IN AN ARGON GLOW DISCHARGE
    OLESON, NL
    PHYSICAL REVIEW, 1955, 98 (02): : 559 - 559