A five-year life-table analysis on wide neck ITI implants with prosthetic evaluation and radiographic analysis: results from a private practice

被引:40
作者
Bischof, Mark
Nedir, Rabah
Najm, Simon Abi
Szmukler-Moncler, Serge
Samson, Jacky
机构
[1] Swiss Dent Clin Grp, Clin Dent Chauderon, CH-1003 Lausanne, Switzerland
[2] Univ Geneva, Sch Dent Med, Dept Stomatol & Oral Surg, CH-1211 Geneva 4, Switzerland
关键词
ITI implants; medium term; posterior mandible; posterior maxilla; private practice; prosthetic complications; radiographical evaluation; short implants; single molar crown; SLA; wide implants;
D O I
10.1111/j.1600-0501.2006.01271.X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This paper reports a 5-year life-table analysis on wide neck (WN) ITI implants placed in a private practice. In 212 patients, 263 implants were placed in the posterior region; 97% rehabilitated the molar area. Implants in the mandible and in the maxilla were 61.2% and 38.8%, respectively; the mean implant length was 9.7 and 8.9 mm, respectively. Eighty-nine percent sites had both vestibular and buccal bone lamellae >= 1 mm, 9.1% had one of them < 1 mm and 1.9% had both lamellae < 1 mm. Sinus perforation during surgery occured in 52% of the maxillary implants. Prosthetic information was available for 249 implants; implants were involved in 157 single crowns (SC) and 80 fixed partial dentures (FPD). Radiographic analysis was performed on 102 implants that reached the 2-year control, and crestal bone loss (CBL) was measured. Results showed that five implants failed; the 5-year cumulative survival rate was 97.89%. The 1-year survival rate based on 259 implants was 98.8% and the 2-year survival rate based on 174 implants was 97.7%. In this 5-year timeframe, 94.3% of the SCs and 96.2% of the FPDs were free of complication. The mean CBL at the mesial and distal sides was 0.71 and 0.60 mm, respectively; bone losses > 1 and > 2 mm were recorded for 29.7% and 2.5% of the sides, respectively. This mid-term study showed that the WN ITI implants were highly predictable in private practice and that prosthetic complication in the molar area was an infrequent event.
引用
收藏
页码:512 / 520
页数:9
相关论文
共 42 条
[1]   Use of 5-mm-diameter implants:: Periotest® values related to a clinical and radiographic evaluation [J].
Aparicio, C ;
Orozco, P .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (06) :398-406
[2]  
Balshi T J, 1996, Int J Oral Maxillofac Implants, V11, P372
[3]  
Behneke A, 2000, INT J ORAL MAX IMPL, V15, P633
[4]  
Behneke A, 2002, INT J ORAL MAX IMPL, V17, P799
[5]  
Behneke A, 1997, INT J ORAL MAX IMPL, V12, P749
[6]  
BERNARD JP, 2001, CLIN ORAL IMPLAN RES, V12, P395
[7]  
BISCHOF M, 2002, CLIN ORAL IMPLAN RES, V13, pR23
[8]  
Blatz MB, 1998, INT J PROSTHODONT, V11, P356
[9]   Economic aspects of single-tooth replacement [J].
Brägger, U ;
Krenander, P ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (03) :335-341
[10]   Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants [J].
Bragger, U ;
Hafeli, U ;
Huber, B ;
Hammerle, CHF ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (04) :218-224