Effect of non-condensable gas on the start-up of a gravity loop thermosyphon with gas-liquid separator

被引:17
作者
Huang, Jian [1 ]
Wang, Li [1 ,2 ]
Shen, Jianbiao [1 ]
Liu, Chuanping [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Mech Engn, Beijing 100083, Peoples R China
[2] Beijing Engn Res Ctr Energy Saving & Environm Pro, Beijing 100083, Peoples R China
关键词
Non-condensable gas; Start-up; NCG-vapor blocks zone; Pressure peak curve; OPERATION; STEAM;
D O I
10.1016/j.expthermflusci.2015.11.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study experimentally investigated the influence of non-condensable gas (NCG) on the start-up time of gravity loop thermosyphon (GLT) developed for regenerative building heating exchangers. A gas-liquid separator was added to the end of the condensate line in the GLT. Given characteristics of the NCG that accumulated in the gas-liquid separator, and the NCG is prevented from circulating in the loop, thereby effectively lowering the effect of NCG on heat exchange. The presence of NCG not only influenced the local condensation heat transfer of the condenser but also affected the start-up of the loop thermosyphon. Results of the experimental investigation revealed that the presence of NCG increased the start-up time of GLT. A higher NCG level corresponds to, a longer start-up time. In particular, the start-up time was 2.8 times more than that in the evacuation when amount of NCG was 30% in volume. The NCG-vapor blocks zone hinders the vapor transmission from the evaporator to the condenser in the vapor line between the evaporator and condenser, further causing a rapid increase in system pressure during start-up. Moreover, obvious pressure peak curve phenomena occurred in a number of conditions, such as heat load was greater than or equal 2.0 kW and amount of NCG was less than or equal 30% in volume. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 20 条
[1]   FREE CONVECTION FILM CONDENSATION OF STEAM IN PRESENCE OF NON-CONDENSING GASES [J].
ALDIWANY, HK ;
ROSE, JW .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (07) :1359-1369
[2]  
Baumann J., 1999, SOC AUTOMOT ENG, P2048
[3]   Sub-atmospheric boiling heat transfer and thermal performance of two-phase loop thermosyphon [J].
Chang, S. W. ;
Lo, D. C. ;
Chiang, K. F. ;
Lin, C. Y. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 39 :134-147
[4]  
Collier JG., 1994, CONVECTIVE BOILING C
[5]   The effects of non-condensable gases on the performance of loop thermosyphon heat exchangers [J].
Dube, V ;
Akbarzadeh, A ;
Andrews, J .
APPLIED THERMAL ENGINEERING, 2004, 24 (16) :2439-2451
[6]  
Dunn P., 1994, Heat Pipes, V4th
[7]  
Hasanein H. A., 1994, THESIS MIT
[8]   Effect of non-condensable gas on steady-state operation of a loop thermosyphon [J].
He, Jiang ;
Lin, Guiping ;
Bai, Lizhan ;
Miao, Jianyin ;
Zhang, Hongxing ;
Wang, Lu .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 81 :59-67
[9]   Effect of non-condensable gas on the operation of a loop heat pipe [J].
He, Jiang ;
Lin, Guiping ;
Bai, Lizhan ;
Miao, Jianyin ;
Zhang, Hongxing .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 70 :449-462
[10]   Effect of non-condensable gas on startup of a loop thermosyphon [J].
He, Jiang ;
Lin, Guiping ;
Bai, Lizhan ;
Miao, Jianyin ;
Zhang, Hongxing ;
Wang, Lu .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 72 :184-194