A high-throughput bioanalytical platform using automated infusion for tandem mass spectrometric method optimization and its application in a metabolic stability screen

被引:40
作者
Kieltyka, Kasia [1 ]
Zhang, Jun [1 ]
Li, Shu [1 ]
Vath, Marianne [1 ]
Baglieri, Chris [1 ]
Ferraro, Cheryl [1 ]
Zvyaga, Tatyana A. [1 ]
Drexler, Dieter M. [1 ]
Weller, Harold N. [1 ]
Shou, Wilson Z. [1 ]
机构
[1] Bristol Myers Squibb Co, Wallingford, CT 06492 USA
关键词
LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; QUANTITATIVE-ANALYSIS; DRUG DISCOVERY; ION-TRAP; SYSTEM; SAMPLES; PLASMA; ASSAYS;
D O I
10.1002/rcm.4037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the bioanalytical method of choice to support plate-based, in vitro early ADME (Absorption, Distribution, Metabolism and Excretion) screens such as metabolic stability (Metstab) assessment. MS/MS method optimization has historically been the bottleneck in this environment, where samples from thousands of discrete compounds are analyzed on a monthly basis, mainly due to the lack of a high-quality commercially available platform to handle the necessary MS/MS method optimization steps for sample analysis by selected reaction monitoring (SRM) on triple quadrupole mass spectrometers. To address this challenge, we recently developed a highly automated bioanalytical platform by successfully integrating QuickQuan (TM) 2.0, a unique high-throughput solution featuring MS/MS method optimization by automated infusion, with a customized in-house software tool in support of a Metstab screen. In this platform, a dual-column setup running parallel chromatography was also implemented to reduce the bioanalytical cycle time for LC/MS/MS sample analysis. A set of 45 validation compounds was used to demonstrate the speed, quality and reproducibility of MS/MS method optimization, sample analysis, and data processing using this automated platform. Metstab results for the validation compounds in microsomes from multiple species (human, rat, mouse) showed good consistency within each batch, and also between batches conducted on different days. We have achieved and maintained a monthly throughput of 1300 compound assays representing 500 discrete compounds per instrument per month on this platform, and it has been used to generate metabolic stability data for more than 25 000 compounds to date with an overall success rate of more than 95%. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:1579 / 1591
页数:13
相关论文
共 26 条
[1]   Automatic mass spectrometry method development for drug discovery: application in metabolic stability assays [J].
Chovan, LE ;
Black-Schaefer, C ;
Dandliker, PJ ;
Lau, YY .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (24) :3105-3112
[2]   An automated high throughput liquid chromatography-mass spectrometry process to assess the metabolic stability of drug candidates [J].
Drexler, Dieter M. ;
Belcastro, James V. ;
Dickinson, Kenneth E. ;
Edinger, Kurt J. ;
Hnatyshyn, Serhiy Y. ;
Josephs, Jonathan L. ;
Langish, Robert A. ;
McNaney, Colleen A. ;
Santone, Kenneth S. ;
Shipkova, Petia A. ;
Tymiak, Adrienne A. ;
Zvyaga, Tatyana A. ;
Sanders, Mark .
ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2007, 5 (02) :247-264
[3]   High-throughput mass Spectrometry screening for inhibitors of phosphatidylserine decarboxylase [J].
Forbes, Chris D. ;
Toth, Joshuaine G. ;
Oezbal, Can C. ;
LaMarr, William A. ;
Pendleton, Jennifer A. ;
Rocks, Sandra ;
Gedrich, Richard W. ;
Osterman, David G. ;
Landro, James A. ;
Lumb, Kevin J. .
JOURNAL OF BIOMOLECULAR SCREENING, 2007, 12 (05) :628-634
[4]   Higher-throughput screening for Caco-2 permeability utilizing a multiple sprayer liquid chromatography/tandem mass spectrometry system [J].
Fung, EN ;
Chu, IH ;
Li, C ;
Liu, TT ;
Soares, A ;
Morrison, R ;
Nomeir, AA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (18) :2147-2152
[5]   A generic fast solid-phase extraction high-performance liquid chromatography/mass spectrometry method for high-throughput drug discovery [J].
Gao, Lan ;
Cheng, Xueheng ;
Zhang, Jun ;
Burns, David J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (21) :3497-3504
[6]  
HERBST JJ, 2005, AM PHARM REV, V8, P96
[7]   A high capacity LC/MS system for the bioanalysis of samples generated from plate-based metabolic screening [J].
Janiszewski, JS ;
Rogers, KJ ;
Whalen, KM ;
Cole, MJ ;
Liston, TE ;
Duchoslav, E ;
Fouda, HG .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1495-1501
[8]  
Kaplita P.V., 2005, JALA-J ASSOC LAB AUT, V10, P140
[9]  
Kassel DB, 2005, USING MASS SPECTROMETRY FOR DRUG METABOLISM STUDIES, P83
[10]  
Kerns EH, 2006, CURR DRUG METAB, V7, P457