Simultaneous determination of fluoroquinolones, sulfonamides and tetracyclines in sewage sludge by pressurized liquid extraction and liquid chromatography electrospray ionization-mass spectrometry

被引:111
|
作者
Lillenberg, Merike [2 ]
Yurchenko, Sergei [3 ]
Kipper, Karin [3 ]
Herodes, Koit [3 ]
Pihl, Viljar [3 ]
Sepp, Kalev [4 ]
Lohmus, Ruenno [5 ]
Nei, Lembit [1 ]
机构
[1] Tallinn Univ Technol, Tartu Coll, Environm Protect Dept, EE-51008 Tartu, Estonia
[2] Estonian Univ Life Sci, Dept Food Sci & Hyg, EE-51014 Tartu, Estonia
[3] Univ Tartu, Inst Chem, EE-51014 Tartu, Estonia
[4] Estonian Univ Life Sci, Dept Landscape Management & Nat Conservat, EE-51014 Tartu, Estonia
[5] Univ Tartu, Inst Phys, EE-51014 Tartu, Estonia
关键词
Sewage sludge; Fluoroquinolones; Tetracyclines; Sulfonamides; PLE; SPE; HPLC-ESI-MS; SOLID-PHASE EXTRACTION; VETERINARY ANTIBIOTICS; FLUORESCENCE DETECTION; ANTIBACTERIAL AGENTS; ASSISTED EXTRACTION; PIG SLURRY; SOIL; WATER; QUINOLONES; RESIDUES;
D O I
10.1016/j.chroma.2009.06.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new scheme for the quantitative determination of traces of fluoroquinolones (FQs), tetracyclines (TCs) and sulfonamides (SAs) in sewage sludge was developed. The compounds were simultaneously extracted from sewage sludge by pressurized liquid extraction (PLE). A novel and effective method for PLE was developed. Solid-phase extraction was used for cleaning up the extracts. Identification and quantification of the compounds was done using high-performance liquid chromatography with electrospray ionization mass spectrometry in selected reaction monitoring mode. The best recovery of FQs and TCs was obtained by using hydrophilic-lipophilic balance cartridges, recoveries ranged 59% for norfloxacin to 82% for ofloxacin and 95% for doxycycline; for SAs strong cation-exchange cartridges were more efficient, recoveries were 96% for sulfamethoxazole and 43% for sulfadimethoxine. Limit of quantification ranged from 0.1 ng/g for SAs to 160 ng/g for tetracycline. Method precision for TCs was 5.06% and 1.12%, and for SAs 0.43% and 2.01%. FQs precision ranged from 0.77% to 1.89%. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5949 / 5954
页数:6
相关论文
共 50 条
  • [1] Determination of antibiotics (tetracyclines and sulfonamides) in biosolids by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry
    Pamreddy, Annapurna
    Hidalgo, Manuela
    Havel, Josef
    Salvado, Victoria
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1298 : 68 - 75
  • [2] Simultaneous determination of 14 sulfonamides and tetracyclines in biogas plants by liquid-liquid-extraction and liquid chromatography tandem mass spectrometry
    Astrid Spielmeyer
    Jenny Ahlborn
    Gerd Hamscher
    Analytical and Bioanalytical Chemistry, 2014, 406 : 2513 - 2524
  • [3] Simultaneous determination of 14 sulfonamides and tetracyclines in biogas plants by liquid-liquid-extraction and liquid chromatography tandem mass spectrometry
    Spielmeyer, Astrid
    Ahlborn, Jenny
    Hamscher, Gerd
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (11) : 2513 - 2524
  • [4] Determination of tetramine in marine gastropods by liquid chromatography/electrospray ionization-mass spectrometry
    Kawashima, Y
    Nagashima, Y
    Shiomi, K
    TOXICON, 2004, 44 (02) : 185 - 191
  • [5] Simultaneous determination of sulfonamides and fluoroquinolones residues in chicken by high performance liquid chromatography-electrospray tandem mass spectrometry
    Liu Pengyan
    Jiang Ning
    Wang Yingfeng
    Yan Lizhi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (03) : 348 - 352
  • [6] Determination of palonosetron in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Ding, Li
    Chen, Yan
    Yang, Lin
    Wen, Aidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 575 - 580
  • [7] Determination of berberine in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Hua, Wenyan
    Ding, Li
    Chen, Yan
    Gong, Bin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 931 - 937
  • [8] Determination of the predominant catechins in Acacia catechu by liquid chromatography/electrospray ionization-mass spectrometry
    Shen, Diandian
    Wu, Qingli
    Wang, Mingfu
    Yang, Yonghong
    Lavoie, Edmond J.
    Simon, James E.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (09) : 3219 - 3224
  • [9] Determination of voriconazole in aqueous humor by liquid chromatography-electrospray ionization-mass spectrometry
    Zhou, L
    Glickman, RD
    Chen, N
    Sponsel, WE
    Graybill, JR
    Lam, KW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (02): : 213 - 220
  • [10] Determination of sedative hypnotics in sewage sludge by pressurized liquid extraction with high-performance liquid chromatography and tandem mass spectrometry
    Arbelaez, Paula
    Granados, Judith
    Borrull, Francesc
    Marce, Rosa Maria
    Pocurull, Eva
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (23) : 3481 - 3488