Magnetically aggregated biosensors for sensitive detection of biomarkers at low concentrations

被引:11
作者
Burg, Shmuel [1 ]
Cohen, Meir [1 ]
Margulis, Michael [1 ]
Roth, Shira [1 ]
Danielli, Amos [1 ]
机构
[1] Bar Ilan Univ, Fac Engn, Inst Nanotechnol & Adv Mat, Max & Anna Webb St, IL-5290002 Ramat Gan, Israel
基金
以色列科学基金会;
关键词
LINKED-IMMUNOSORBENT-ASSAY; INTERLEUKIN-8; SERUM; TECHNOLOGIES; DISEASE; DEVICES; ELISA;
D O I
10.1063/1.5108891
中图分类号
O59 [应用物理学];
学科分类号
摘要
Detection of biomarkers at low concentrations is essential for early diagnosis of numerous diseases. In many sensitive assays, the target molecules are tagged using fluorescently labeled probes and captured using magnetic beads. Magnetic beads facilitate washing and separation steps, are well suited for automation, and improve the assay sensitivity. Current devices rely on quantifying the target molecules by detecting the fluorescence signal from individual beads. Thus, to detect low concentrations of target molecules, these devices require sophisticated optical detectors, making them bulky and expensive. Here, we propose a compact fluorescence-based system that simply uses a small permanent magnet with a conic tip to aggregate the magnetic beads, forming a cluster of fluorescently labeled probes whose fluorescence signal is much greater than that of a single bead. Using the magnetically aggregated biosensors to detect human Interleukin-8, we demonstrated a limit of detection of 0.1ng/l and a 4-log dynamic range performance, which is on par with the most sensitive devices but is achieved without their bulk and cost.
引用
收藏
页数:5
相关论文
共 36 条
[1]   Magnetic micro-device for manipulating PC12 cell migration and organization [J].
Alon, N. ;
Havdala, T. ;
Skaat, H. ;
Baranes, K. ;
Marcus, M. ;
Levy, I. ;
Margel, S. ;
Sharoni, A. ;
Shefi, O. .
LAB ON A CHIP, 2015, 15 (09) :2030-2036
[2]   Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method [J].
Baker, Harold N. ;
Murphy, Robin ;
Lopez, Erica ;
Garcia, Carlos .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (65)
[3]   The role of biomarkers and imaging in the clinical diagnosis of dementia [J].
Bayer, Antony J. .
AGE AND AGEING, 2018, 47 (05) :641-643
[4]  
Bio-Rad, 2013, BIOPL PRO HUM CHEM P
[5]   IL-8 plasma concentrations and the risk of future coronary artery disease in apparently healthy men and women - The EPIC-Norfolk prospective population study [J].
Boekholdt, SM ;
Peters, RJG ;
Hack, CE ;
Day, NE ;
Luben, R ;
Bingham, SA ;
Wareham, NJ ;
Reitsma, PH ;
Khaw, KT .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2004, 24 (08) :1503-1508
[6]   An analytical comparison of three immunoassay platforms for subpicomolar detection of protein biomarker GAD65 [J].
Costa, Olivier R. ;
Verhaeghen, Katrijn ;
Roels, Sarah ;
Starige, Geert ;
Ling, Zhidong ;
Pipeleers, Daniel ;
Gorus, Frans K. ;
Martens, Geert A. .
PLOS ONE, 2018, 13 (03)
[7]   Detection of fluorescent-labeled probes at subpicomolar concentrations by magnetic modulation [J].
Danielli, Amos ;
Arie, Ady ;
Porat, Noga ;
Ehrlich, Marcelo .
OPTICS EXPRESS, 2008, 16 (23) :19253-19259
[8]   Magnetic Modulation Biosensing for Rapid and Homogeneous Detection of Biological Targets at Low Concentrations [J].
Danielli, Amos ;
Porat, Noga ;
Ehrlich, Marcelo ;
Arie, Ady .
CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2010, 11 (01) :128-137
[9]   Rapid homogenous detection of the Ibaraki virus NS3 cDNA at picomolar concentrations by magnetic modulation [J].
Danielli, Amos ;
Porat, Noga ;
Arie, Ady ;
Ehrlich, Marcelo .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) :858-863
[10]   Applications of Luminex® xMAP™ technology for rapid, high-throughput multiplexed nucleic acid detection [J].
Dunbar, SA .
CLINICA CHIMICA ACTA, 2006, 363 (1-2) :71-82