Effectiveness of the GentleWave System in Removing Separated Instruments

被引:17
作者
Wohlgemuth, Pierre [1 ]
Cuocolo, Davide [1 ]
Vandrangi, Prashantbi [2 ]
Sigurdsson, Asgeir [1 ]
机构
[1] NYU, Coll Dent, Dept Endodont, New York, NY 10010 USA
[2] Sonendo Inc, Laguna Hills, CA USA
关键词
File separation; GentleWave System; Multisonics Ultra-cleaning; steel hand files; TITANIUM ENDODONTIC INSTRUMENTS; ROOT CANALS; FRACTURED INSTRUMENTS; IN-VITRO; FILES; EFFICIENCY; SUCCESS; MOLARS;
D O I
10.1016/j.joen.2015.08.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: A separated instrument in a root canal system has the potential of severely affecting the outcome of endodontic therapy. This study evaluated the effectiveness of the minimally invasive Gentle Wave System (Sonendo Inc, Laguna Hills, CA) in removing separated stainless steel endodontic files from the apical and midroot regions of molar root canals. Methods: Thirty-six extracted human molars were accessed, and the glide path was confirmed to the apex. ISO #10, #15, and #20 K-file fragments of 2.5-mm length were separated at the apical (n = 18) or midroot (n = 18) region of the molars by engaging a weakened file with downward pressure. During analysis, the teeth were divided into 2 curved groups based on the curvature of the root (<300 and >30). The success rate of instrument removal and the treatment time were noted. Statistical comparison was done with the Fisher exact test and independent 2-sample t test (P < .05). Results: The overall success rate of instrument removal when the separated files were engaged in the apical region was 61%, and for the nnidroot region, it was 83%. Less curved canals (<30 degrees) showed a 91% success rate (n = 24), whereas canals with an angle of curvature greater than 30 showed a 42% success rate (n = 12). The median treatment time for instrument retrieval was 10 minutes 44 seconds. Conclusions: The results revealed that the GentleWave System is effective in retrieving separated instruments while conserving the dentinal structure.
引用
收藏
页码:1895 / 1898
页数:4
相关论文
共 33 条
[1]   Evaluating Two Techniques on Removal of Fractured Rotary Nickel-Titanium Endodontic Instruments from Root Canals: An In Vitro Study [J].
Alomairy, Khalid H. .
JOURNAL OF ENDODONTICS, 2009, 35 (04) :559-562
[2]  
[Anonymous], EUR J DENT
[3]   Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments [J].
Bahia, MGA ;
Martins, RC ;
Gonzalez, BM ;
Buono, VTL .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (11) :795-801
[4]  
Charara K, 2015, J ENDOD IN PRESS
[5]   RELATIONSHIP OF BROKEN ROOT CANAL INSTRUMENTS TO ENDODONTIC CASE PROGNOSIS - A CLINICAL INVESTIGATION [J].
CRUMP, MC ;
NATKIN, E .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1970, 80 (06) :1341-+
[6]   Broken instrument removal - Two cases [J].
D'Arcangelo, C ;
Varvara, G ;
De Fazio, P .
JOURNAL OF ENDODONTICS, 2000, 26 (06) :368-370
[7]   Apical microleakage of root-end cavities prepared by CO2 laser [J].
Esen, E ;
Yoldas, O ;
Kürkçü, M ;
Dogan, MC ;
Seydaoglu, G .
JOURNAL OF ENDODONTICS, 2004, 30 (09) :662-664
[8]   RETRIEVING BROKEN ENDODONTIC INSTRUMENTS [J].
FELDMAN, G ;
SOLOMON, C ;
NOTARO, P ;
MOSKOWITZ, E .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1974, 88 (03) :588-591
[9]   A METHOD FOR THE REMOVAL OF BROKEN ENDODONTIC INSTRUMENTS FROM ROOT CANALS [J].
FORS, UGH ;
BERG, JO .
JOURNAL OF ENDODONTICS, 1983, 9 (04) :156-159
[10]   Tissue Dissolution by a Novel Multisonic Ultracleaning System and Sodium Hypochlorite [J].
Haapasalo, Markus ;
Wang, Zhejun ;
Shen, Ya ;
Curtis, Allison ;
Patel, Payal ;
Khakpour, Mehrzad .
JOURNAL OF ENDODONTICS, 2014, 40 (08) :1178-1181