In-capillary solid-phase extraction-capillary electrophoresis for the determination of chlorophenols in water

被引:36
作者
Zhang, Luo-Hong
Zhang, Cheng-Jie
Chen, Xueming
Feng, Yu-Qi
Wu, Xing-Zheng
机构
[1] Univ Fukui, Dept Mat Sci & Engn, Fac Engn, Fukui 9108507, Japan
[2] Zhejiang Univ, Inst Environm Engn, Zhejiang, Peoples R China
[3] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
capillary electrophoresis; chlorophenols; sample preconcentration; solid-phase extraction;
D O I
10.1002/elps.200500700
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel CE method combined with SPE in a single capillary was developed for analysis of chlorophenols in water. A frit of 0.5 mm was first made by a sol-gel method, followed by packing a SPE sorbent in the inlet end of the capillary. Two phenol derivatives, 2,4-dichlorophenol and 2,4,5-trichlorophenol, were used as the model compounds. By loading sample solutions into the capillary, the two chlorophenols were extracted into the sorbent. They were desorbed by injecting only about 4 nL of methanol. Finally, the analytes were separated by conventional CE. The technique provided a concentration enhancement factor of over 4000-fold for both chlorophenols. The detection limits (S/N = 3) of 2,4-dichlorophenol and 2,4,5-trichlorophenol were determined to be 0.1 ng/mL and 0.07 ng/mL, respectively. For replicate analyses of 5ng/mL of 2,4-dichlorophenol, within-day and between-day RSDs of migration time, peak height and peak area were in the range of 1.8-2.0%, 4.0-4.4% and 4.1-4.6%, respectively. The method shows wide linear range, acceptable reproducibility and excellent sensitivity, and it was applied to the analyses of spiked river water samples. The capillary packed with the SPE sorbents can be used for more than 400 runs without performance deterioration.
引用
收藏
页码:3224 / 3232
页数:9
相关论文
共 55 条
[11]   Large-volume sample stacking in acidic buffer for analysis of small organic and inorganic anions by capillary electrophoresis [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :995-1001
[12]   ISOTACHOPHORETIC DESORPTION OF ANIONIC COMPOUNDS FROM SOLID-PHASE ADSORBENTS [J].
HENDRIKS, PJM ;
CLAESSENS, HA ;
VERHOEVEN, JTH ;
NOIJ, THM ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY A, 1993, 655 (02) :325-330
[13]   The relative influences of acidity and polarity on responsiveness of small organic molecules to analysis with negative ion electrospray ionization mass spectrometry (ESI-MS) [J].
Henriksen, T ;
Juhler, RK ;
Svensmark, B ;
Cech, NB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (04) :446-455
[14]   Combining solid-phase microextraction and on-line preconcentration-capillary electrophoresis sensitive analysis of pesticides in foods [J].
Hernández-Borges, J ;
Cifuentes, A ;
García-Montelongo, FJ ;
Rodríguez-Delgado, MA .
ELECTROPHORESIS, 2005, 26 (4-5) :980-989
[15]   Dynamic three-phase microextraction as a sample preparation technique prior to capillary electrophoresis [J].
Hou, L ;
Lee, HK .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2784-2789
[16]   Latex-coated polymeric monolithic ion-exchange stationary phases. 1. Anion-exchange capillary electrochromatography and in-line sample preconcentration in capillary electrophoresis [J].
Hutchinson, JP ;
Zakaria, P ;
Bowiet, AR ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :407-416
[17]  
Jemere AB, 2002, ELECTROPHORESIS, V23, P3537, DOI 10.1002/1522-2683(200210)23:20<3537::AID-ELPS3537>3.0.CO
[18]  
2-9
[19]   DETERMINATION OF CHLORIDE, NITRATE, SULFATE, NITRITE, FLUORIDE, AND PHOSPHATE BY ON LINE COUPLED CAPILLARY ISOTACHOPHORESIS-CAPILLARY ZONE ELECTROPHORESIS WITH CONDUCTIVITY DETECTION [J].
KANIANSKY, D ;
ZELENSKY, I ;
HYBENOVA, A ;
ONUSKA, FI .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4258-4264
[20]   A protein-encapsulation technique by the sol-gel method for the preparation of monolithic columns for capillary electrochromatography [J].
Kato, M ;
Sakai-Kato, K ;
Matsumoto, N ;
Toyo'oka, T .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1915-1921