Simultaneous analysis of 237Np and Pu isotopes in environmental samples by ICP-SF-MS coupled with automated sequential injection system

被引:77
作者
Kim, CS
Kim, CK
Lee, KJ
机构
[1] Korea Inst Nucl Safety, Taejon 305338, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon, South Korea
关键词
D O I
10.1039/b400034j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simultaneous analytical method for Np-237, Pu-239 and Pu-240 has been developed using sector field inductively coupled plasma mass spectrometry (ICP-SF-MS) detection combined with an automated sequential injection ( SI) separation system. The chemical purification of these actinides was carried out on an actinide-specific extraction chromatographic resin, TEVA-Spec, in an automated SI system. The similar chemical behaviors of Np and Pu on TEVA-Spec was confirmed by recovery test after treating with ascorbic acid in 5 M HNO3. TEVA-Spec maintained its re-usability, giving high and consistent chemical recovery, and showed good selectivity for Np and Pu and a low memory effect during the consecutive analysis of nine replicate samples. The high chemical recovery (>90%), reliable accuracy and repeatability of Np-237 and Pu isotope purification using the SI system were proved using standard reference materials. Low detection limits of 2.5, 2.1 and 0.42 fg ml(-1) were obtained for Np-237, Pu-239 and Pu-240, respectively, which make it possible to analyze these nuclides in samples of soil and sediment as low as 1 g. With the exception of the preparation process required prior to loading a sample, all chemical purifications were carried out automatically by the programmed SI system, and were completed within 1 hour, which included measurement by ICP-SF-MS. This method was successfully applied to the analysis of the environmental levels of Np-237 and Pu in soil, sediment and in biological samples.
引用
收藏
页码:743 / 750
页数:8
相关论文
共 32 条
[1]   Np-237/Pu-239 atom ratios in integrated global fallout: a reassessment of the production of Np-237 [J].
Beasley, TM ;
Kelley, JM ;
Maiti, TC ;
Bond, LA .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1998, 38 (02) :133-146
[2]   242Pu as tracer for simultaneous determination of 237Np and 239,240Pu in environmental samples [J].
Chen, QJ ;
Dahlgaard, H ;
Nielsen, SP ;
Aarkrog, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 253 (03) :451-458
[3]  
CHIAPPINI R, 1999, J ANAL ATOM SPECTROM, V14, P933
[4]   Sources of the transuranic elements plutonium and neptunium in arctic marine sediments [J].
Cooper, LW ;
Kelley, JM ;
Bond, LA ;
Orlandini, KA ;
Grebmeier, JM .
MARINE CHEMISTRY, 2000, 69 (3-4) :253-276
[5]   Extraction chromatographic separations and analysis of actinides using sequential injection techniques with on-line inductively coupled plasma mass spectrometry (ICP MS) detection [J].
Egorov, OB ;
O'Hara, MJ ;
Farmer, OT ;
Grate, JW .
ANALYST, 2001, 126 (09) :1594-1601
[6]  
*EICHR IND, 1996, EXTR CHROM MAT RAP S
[7]   Automated extraction chromatographic separations of actinides using separation-optimized sequential injection techniques [J].
Grate, JW ;
Egorov, OB ;
Fiskum, SK .
ANALYST, 1999, 124 (08) :1143-1150
[8]  
HOPPERS DD, 1981, SRM4350B NAT I STAND
[9]   SEPARATION AND PRECONCENTRATION OF ACTINIDES BY EXTRACTION CHROMATOGRAPHY USING A SUPPORTED LIQUID ANION-EXCHANGER - APPLICATION TO THE CHARACTERIZATION OF HIGH-LEVEL NUCLEAR WASTE SOLUTIONS [J].
HORWITZ, EP ;
DIETZ, ML ;
CHIARIZIA, R ;
DIAMOND, H ;
MAXWELL, SL ;
NELSON, MR .
ANALYTICA CHIMICA ACTA, 1995, 310 (01) :63-78
[10]  
IAEA, 1984, IAEARL111