Dosimetric comparison of four target alignment methods for prostate cancer radiotherapy

被引:45
作者
O'Daniel, Jennifer C.
Dong, Lei
Zhang, Lifei
de Crevoisier, Renaud
Wang, He
Lee, Andrew K.
Cheung, Rex
Tucker, Susan L.
Kudchadker, Rajat J.
Bonnen, Mark D.
Cox, James D.
Mohan, Radhe
Kuban, Deborah A.
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Biostat & Appl Math, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 66卷 / 03期
关键词
image-guided radiotherapy; setup uncertainties; image guidance; dosimetric comparison; CT-guided;
D O I
10.1016/j.ijrobp.2006.06.044
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to compare the dosimetric consequences of 4 treatment delivery techniques for prostate cancer patients treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: During an 8-week course of radiotherapy, 10 patients underwent computed tomography (CT) scans 3 times per week (243 total) before daily treatment with a CT-linear accelerator. Treatment delivery was simulated by realigning a fixed-margin treatment plan on each CT scan and calculating doses. The alignment methods were those based on the following: skin marks, bony registration, ultrasonography (US), and in-room CT. For the last two methods, prostate was the alignment target. The dosimetric effects of these alignment methods on the prostate, seminal vesicles, rectum, and bladder were compared. The average daily minimum dose to 0.1 cm(3) was used as the metric for target coverage. Results: Skin and bone alignments provided acceptable prostate coverage for only 70% of patients, US alignment for 90%, and CT alignment for 100%. CT-based alignment of the prostate provided seminal vesicle (SV) coverage of >= 69 Gy for all patients; US and bone alignments provided SV coverage of 2:60 Gy. This SV coverage may be acceptable for early-stage cancer (equivalent SV dose = 55.8 Gy at 1.8 Gy per fraction), but unacceptable for late-stage cancer (SV dose = 75.6 Gy). At 75.6 Gy, the acceptable rate for SV coverage was 40% for skin and bone alignments, 70% for US, and 80% for CT. Conclusions: Direct target alignment methods (US and CT) provided better target coverage. CT-guided alignment provided the best and most consistent dosimetric coverage. A larger planning target volume margin is needed for SV coverage when the alignment target is the prostate. (c) 2006 Elsevier Inc.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 35 条
[1]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[2]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[3]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[4]   Experience of ultrasound-based daily prostate localization [J].
Chandra, A ;
Dong, L ;
Huang, E ;
Kuban, DA ;
O'Neill, L ;
Rosen, I ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :436-447
[5]   Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system [J].
Court, L ;
Rosen, I ;
Mohan, R ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (06) :1198-1210
[6]   Automatic registration of the prostate for computed-tomography-guided radiotherapy [J].
Court, LE ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (10) :2750-2757
[7]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[8]   Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers [J].
De Boer, HCJ ;
Van Os, MJH ;
Jansen, PP ;
Heumen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (04) :969-983
[9]   A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[10]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444