Investigation of the Thermal Characteristics of a Reusable Radiochromic Gel Dosimeter

被引:0
|
作者
Ono, K. [1 ]
Fujino, K. [1 ]
Hayashi, S. [2 ]
Hioki, K. [3 ]
Miyazawa, M. [4 ]
Akagi, Y. [1 ]
Hirokawa, Y. [1 ]
机构
[1] Hiroshima Heiwa Clin, Hiroshima, Japan
[2] Hiroshima Int Univ, Hiroshima, Japan
[3] Hiroshima Univ Hosp, Hiroshima, Japan
[4] R TECH INC, Tokyo, Japan
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-DBRA-
引用
收藏
页码:E122 / E122
页数:1
相关论文
共 50 条
  • [31] Diffusion properties of a radiochromic hydrogel dosimeter
    Skyt, P. S.
    Kinnari, T. S.
    Wahlstedt, I.
    Yates, E. S.
    Muren, L. P.
    Petersen, J. B. B.
    Balling, P.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [32] Dosimetric characteristics of a reusable 3D radiochromic dosimetry material
    Park, Jong Min
    Park, So-Yeon
    Choi, Chang Heon
    Chun, Minsoo
    Han, Ji Hye
    Cho, Jin Dong
    Kim, Jung-in
    PLOS ONE, 2017, 12 (07):
  • [33] A REUSABLE ELECTRET DOSIMETER
    PRETZSCH, G
    DORSCHEL, B
    RADIATION PROTECTION DOSIMETRY, 1985, 12 (04) : 351 - 354
  • [34] Three-Dimensional Isocenter Verification for Real-Time Tumor-Tracking Radiotherapy System Using a Reusable PVA-I Radiochromic Gel Dosimeter
    Ono, K.
    Sera, T.
    Shiinoki, T.
    Hayashi, S.
    Fujino, K.
    Akagi, Y.
    Hirokawa, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E865 - E865
  • [35] An investigation of a novel reusable radiochromic sheet for 2D dose measurement
    Collins, Cielle
    Yoon, Suk Whan
    Kodra, Jacob
    Coakley, Robert
    Subashi, Ergys
    Sidhu, Kulbir
    Adamovics, John
    Oldham, Mark
    MEDICAL PHYSICS, 2019, 46 (12) : 5758 - 5769
  • [36] Novel Radiochromic Film Dosimeter for Radiotherapy Applications
    Chopra, N.
    Liu, K.
    Beddar, S.
    Schueler, E.
    MEDICAL PHYSICS, 2022, 49 (06) : E326 - E327
  • [37] TEMPERATURE EFFECTS ON THE RESPONSE OF A RADIOCHROMIC FILM DOSIMETER
    KHAN, HM
    WAHID, MS
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1994, 16 (01): : 8 - 12
  • [38] Preliminary study on a bifunctional, elastic NBT-PVA radiochromic gel acting as a bolus and dosimeter in radiotherapy
    Jaszczak-Kuligowska, M.
    Maras, P.
    Kozicki, M.
    13TH INTERNATIONAL CONFERENCE ON 3D DOSIMETRY, IC3DDOSE 2024, 2024, 2799
  • [39] Spatial resolution of a stacked radiochromic film dosimeter
    Butson, MJ
    Cheung, T
    Yu, PKN
    RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 211 - 213
  • [40] Evaluation of Pliable Fading Radiochromic Sheet Dosimeter
    Jordan, K.
    Adamovics, J.
    Coakley, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E313 - E313