The response of xenon X-ray detectors to full-energy absorption and fluorescence-escape events: Measurement and modelling

被引:8
作者
Dias, THVT
Santos, FP
dosSantos, JMF
Lopes, JAM
Veloso, JFCA
Rachinhas, PJBM
Morgado, RE
Stauffer, AD
Conde, CAN
机构
[1] LOS ALAMOS NATL LAB,LOS ALAMOS,NM 87545
[2] YORK UNIV,DEPT PHYS,TORONTO,ON M3J 1P3,CANADA
关键词
D O I
10.1109/23.507079
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have observed that the pulse-height distributions of x-ray events that deposit essentially the same amount of energy in a xenon gas detector will vary according to the deexcitation pathways available to the photoionized atoms. A xenon gas proportional scintillation counter was used to compare the pulse-height distributions of events in which fluorescence x-rays from xenon escape detection. Experimental results are presented and the behaviour for different types of events is clarified using Monte Carlo simulation. The results indicate that particular care must be taken when using escape peaks for energy calibration of xenon gas detectors.
引用
收藏
页码:1432 / 1441
页数:10
相关论文
共 17 条
[1]  
BIRKS LS, 1974, HDB SPECTROSCOPY, V1, P3
[2]   The response functions of the HEPC/LEPC detector system measured at the Xe L edge region [J].
BudtzJorgensen, C ;
Olesen, C ;
Schnopper, HW ;
Lederer, T ;
Scholze, F ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :83-87
[3]  
CEDERQUIST H, 1992, PHYS REV A, V47, pR4551
[4]  
DIAS THV, 1993, PHYS REV, V4, P2887
[5]   THE FANO FACTOR IN GASEOUS XENON - A MONTE-CARLO CALCULATION FOR X-RAYS IN THE 0.1 TO 25 KEV ENERGY-RANGE [J].
DIAS, THVT ;
SANTOS, FP ;
STAUFFER, AD ;
CONDE, CAN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (2-3) :341-346
[6]   THE ENERGY NONLINEARITY OF A XENON GAS PROPORTIONAL SCINTILLATION-COUNTER AT THE K-ABSORPTION EDGE IN XENON [J].
DOSSANTOS, JMF ;
MORGADO, RE ;
TAVORA, LMN ;
CONDE, CAN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :216-220
[7]   THE PERFORMANCE OF A COMPACT GAS PROPORTIONAL SCINTILLATION-COUNTER FOR HARD X-RAY SPECTROMETRY [J].
DOSSANTOS, JMF ;
VELOSO, JFCA ;
MORGADO, RE ;
CONDE, CAN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :195-200
[8]  
HOMBECK JA, 1951, PHYS REV, V84, P621
[9]  
Knoll G. F., 1989, RAD DETECTION MEASUR, P160
[10]   THE GAS SCINTILLATION PROPORTIONAL COUNTER IN THE SPACELAB ENVIRONMENT - IN-FLIGHT PERFORMANCE AND POSTFLIGHT CALIBRATION [J].
LAMB, P ;
MANZO, G ;
RE, S ;
BOELLA, G ;
VILLA, G ;
ANDRESEN, R ;
SIMS, MR ;
CLARK, GF .
ASTROPHYSICS AND SPACE SCIENCE, 1987, 136 (02) :369-378