Pedicle Screws Can be 4 Times Stronger Than Lateral Mass Screws for Insertion in the Midcervical Spine A Biomechanical Study on Strength of Fixation

被引:56
作者
Ito, Zenya [1 ,2 ,3 ]
Higashino, Kosaku [2 ]
Kato, Satoshi [2 ]
Kim, Sung Soo [2 ]
Wong, Eugene [2 ]
Yoshioka, Katsuhito [2 ]
Hutton, William C. [1 ,2 ]
机构
[1] Emory Spine Ctr, Dept Orthopaed Surg, Atlanta, GA 30329 USA
[2] VA Med Ctr, Atlanta, GA USA
[3] Nagoya Univ, Sch Med, Dept Orthopaed Surg, Aichi, Japan
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2014年 / 27卷 / 02期
关键词
pullout strength; pedicle screws; biomechanical; lateral mass screws; cervical vertebrae; SUBAXIAL CERVICAL-SPINE; COMPLICATIONS; PLACEMENT; ACCURACY; SYSTEMS;
D O I
10.1097/BSD.0b013e31824e65f4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A biomechanical study. Objective: To compare, in cervical vertebrae (C3-C6), the pullout strengths of pedicle screws and lateral mass screws after both types of screw had been subjected to a period of cyclic loading in 2 planes. Summary of Background Data: In posterior subaxial cervical fixation systems, screws are usually inserted into the lateral mass. As an alternative to lateral mass fixation, pedicle screw fixation became popular in the 1990s and was first used for lower cervical spine trauma cases. However, it is controversial as to whether lateral mass screw fixation in the upper-middle cervical spine offers as much biomechanical security as compared with pedicle screw fixation. Methods: For each of the 32 vertebrae, 1 side was randomly chosen to receive a pedicle screw and the other side a lateral mass screw. The pedicle or lateral mass screws inserted into the first 16 vertebrae were cyclically loaded to simulate torsion and the remaining 16 vertebrae were cyclically loaded to simulate flexion/extension of the spine. At the end of the cyclic loading each screw was pulled out along its long axis. Results: For the torsion group, the mean pullout strength of the pedicle screws was nearly 4 times greater than the mean pullout strength of the lateral mass screws (cf 762 N with 191 N). In contrast, the mean pullout strength of the pedicle screws in the flexion/extension group was only twice the mean pullout strength of the lateral mass screws (cf 571 N with 289 N). Conclusions: Not forgetting the potential risks of inserting pedicle screws in cervical vertebrae, pedicle screws are a better biomechanical choice than lateral mass screws for cervical fixation at the levels C3 through to C6.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 20 条
[11]   Cervical pedicle screws versus lateral mass screws - Anatomic feasibility and biomechanical comparison [J].
Jones, EL ;
Heller, JG ;
Silcox, DH ;
Hutton, WC .
SPINE, 1997, 22 (09) :977-982
[12]   Surgical anatomy of the cervical pedicles: Landmarks for posterior cervical pedicle entrance localization [J].
Karaikovic, EE ;
Kunakornsawat, S ;
Daubs, MD ;
Madsen, RW ;
Gaines, RW .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (01) :63-72
[13]   Accuracy of cervical pedicle screw placement using the funnel technique [J].
Karaikovic, EE ;
Yingsakmongkol, W ;
Gaines, RW .
SPINE, 2001, 26 (22) :2456-2462
[14]   Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine [J].
Kothe, R ;
Rüther, W ;
Schneider, E ;
Linke, B .
SPINE, 2004, 29 (17) :1869-1875
[15]   Placement of pedicle screws in the human cadaveric cervical spine - Comparative accuracy of three techniques [J].
Ludwig, SC ;
Kramer, DL ;
Balderston, RA ;
Vaccaro, AR ;
Foley, KF ;
Albert, TJ .
SPINE, 2000, 25 (13) :1655-1667
[16]   Subaxial Cervical and Cervicothoracic Fixation Techniques-Indications, Techniques, and Outcomes [J].
Pelton, Miguel A. ;
Schwartz, Joseph ;
Singh, Kern .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2012, 43 (01) :19-+
[17]   Pedicle versus lateral mass screws Response [J].
Xu, Risheng ;
Bydon, Ali .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (06) :686-687
[18]   Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients [J].
Wellman, BJ ;
Follett, KA ;
Traynelis, VC .
SPINE, 1998, 23 (02) :193-200
[19]   Biomechanical comparison between C-7 lateral mass and pedicle screws in subaxial cervical constructs [J].
Xu, Risheng ;
McGirt, Matthew J. ;
Sutter, Edward G. ;
Sciubba, Daniel M. ;
Wolinsky, Jean-Paul ;
Witham, Timothy F. ;
Gokaslan, Ziya L. ;
Bydon, Ali .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (06) :688-694
[20]   PEDICLE SCREW PULLOUT STRENGTH - CORRELATION WITH INSERTIONAL TORQUE [J].
ZDEBLICK, TA ;
KUNZ, DN ;
COOKE, ME ;
MCCABE, R .
SPINE, 1993, 18 (12) :1673-1676