Pedicle Screws Can be 4 Times Stronger Than Lateral Mass Screws for Insertion in the Midcervical Spine A Biomechanical Study on Strength of Fixation

被引:56
作者
Ito, Zenya [1 ,2 ,3 ]
Higashino, Kosaku [2 ]
Kato, Satoshi [2 ]
Kim, Sung Soo [2 ]
Wong, Eugene [2 ]
Yoshioka, Katsuhito [2 ]
Hutton, William C. [1 ,2 ]
机构
[1] Emory Spine Ctr, Dept Orthopaed Surg, Atlanta, GA 30329 USA
[2] VA Med Ctr, Atlanta, GA USA
[3] Nagoya Univ, Sch Med, Dept Orthopaed Surg, Aichi, Japan
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2014年 / 27卷 / 02期
关键词
pullout strength; pedicle screws; biomechanical; lateral mass screws; cervical vertebrae; SUBAXIAL CERVICAL-SPINE; COMPLICATIONS; PLACEMENT; ACCURACY; SYSTEMS;
D O I
10.1097/BSD.0b013e31824e65f4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A biomechanical study. Objective: To compare, in cervical vertebrae (C3-C6), the pullout strengths of pedicle screws and lateral mass screws after both types of screw had been subjected to a period of cyclic loading in 2 planes. Summary of Background Data: In posterior subaxial cervical fixation systems, screws are usually inserted into the lateral mass. As an alternative to lateral mass fixation, pedicle screw fixation became popular in the 1990s and was first used for lower cervical spine trauma cases. However, it is controversial as to whether lateral mass screw fixation in the upper-middle cervical spine offers as much biomechanical security as compared with pedicle screw fixation. Methods: For each of the 32 vertebrae, 1 side was randomly chosen to receive a pedicle screw and the other side a lateral mass screw. The pedicle or lateral mass screws inserted into the first 16 vertebrae were cyclically loaded to simulate torsion and the remaining 16 vertebrae were cyclically loaded to simulate flexion/extension of the spine. At the end of the cyclic loading each screw was pulled out along its long axis. Results: For the torsion group, the mean pullout strength of the pedicle screws was nearly 4 times greater than the mean pullout strength of the lateral mass screws (cf 762 N with 191 N). In contrast, the mean pullout strength of the pedicle screws in the flexion/extension group was only twice the mean pullout strength of the lateral mass screws (cf 571 N with 289 N). Conclusions: Not forgetting the potential risks of inserting pedicle screws in cervical vertebrae, pedicle screws are a better biomechanical choice than lateral mass screws for cervical fixation at the levels C3 through to C6.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 20 条
[1]   Complications of pedicle screw fixation in reconstructive surgery of the cervical spine [J].
Abumi, K ;
Shono, Y ;
Ito, M ;
Taneichi, H ;
Kotani, Y ;
Kaneda, K .
SPINE, 2000, 25 (08) :962-969
[2]   One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems [J].
Abumi, K ;
Kaneda, K ;
Shono, Y ;
Fujiya, M .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :19-26
[3]   TRANSPEDICULAR SCREW FIXATION FOR TRAUMATIC LESIONS OF THE MIDDLE AND LOWER CERVICAL-SPINE - DESCRIPTION OF THE TECHNIQUES AND PRELIMINARY-REPORT [J].
ABUMI, K ;
ITOH, H ;
TANEICHI, H ;
KANEDA, K .
JOURNAL OF SPINAL DISORDERS, 1994, 7 (01) :19-28
[4]   Correction of cervical kyphosis using pedicle screw fixation systems [J].
Abumi, K ;
Shono, Y ;
Taneichi, H ;
Ito, M ;
Kaneda, K .
SPINE, 1999, 24 (22) :2389-2396
[5]   ANATOMIC CONSIDERATIONS FOR PLATE-SCREW FIXATION OF THE CERVICAL-SPINE [J].
AN, HS ;
GORDIN, R ;
RENNER, K .
SPINE, 1991, 16 (10) :S548-S551
[6]   POSTERIOR PLATES IN THE MANAGEMENT OF CERVICAL INSTABILITY - LONG-TERM RESULTS IN 44 PATIENTS [J].
FEHLINGS, MG ;
COOPER, PR ;
ERRICO, TJ .
JOURNAL OF NEUROSURGERY, 1994, 81 (03) :341-349
[7]   Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy [J].
Grubb, MR ;
Currier, BL ;
Stone, J ;
Warden, KE ;
An, KN .
SPINE, 1997, 22 (17) :1948-1954
[8]   COMPLICATIONS OF POSTERIOR CERVICAL PLATING [J].
HELLER, JG ;
SILCOX, DH ;
SUTTERLIN, CE .
SPINE, 1995, 20 (22) :2442-2448
[9]   TRANSPEDICULAR SCREW FIXATION OF ARTICULAR MASS FRACTURE-SEPARATION - RESULTS OF AN ANATOMICAL STUDY AND OPERATIVE TECHNIQUE [J].
JEANNERET, B ;
GEBHARD, JS ;
MAGERL, F .
JOURNAL OF SPINAL DISORDERS, 1994, 7 (03) :222-229
[10]  
Johnston Todd L, 2006, Spine J, V6, P667