Complication and Failure Rates with Implant-Supported Fixed Dental Prostheses and Single Crowns: A 10-Year Retrospective Study

被引:173
作者
Wittneben, Julia-Gabriela [1 ]
Buser, Daniel [2 ]
Salvi, Giovanni E. [3 ]
Buergin, Walter [4 ]
Hicklin, Stefan [1 ]
Braegger, Urs [1 ]
机构
[1] Univ Bern, Sch Dent Med, Div Fixed Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol, CH-3010 Bern, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Periodontol, CH-3010 Bern, Switzerland
[4] Univ Bern, Sch Dent Med, CH-3010 Bern, Switzerland
关键词
dental implant; fixed dental implant supported prosthesis; mechanical complication; prosthesis failure; prosthesis survival; single implant crown; technical complication; ACID-ETCHED SURFACE; SUBMERGED TITANIUM IMPLANTS; EDENTULOUS PATIENTS; TECHNICAL COMPLICATIONS; OBSERVATION PERIOD; SURVIVAL; PROTOCOLS; THERAPY;
D O I
10.1111/cid.12066
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose Clinical studies related to the long-term outcomes with implant-supported reconstructions are still sparse. The aim of this 10-year retrospective study was to assess the rate of mechanical/technical complications and failures with implant supported fixed dental prostheses (FDPs) and single crowns (SCs) in a large cohort of partially edentulous patients. Materials and Methods The comprehensive multidisciplinary examination consisted of a medical/dental history, clinical examination, and a radiographic analysis. Prosthodontic examination evaluated the implant-supported reconstructions for mechanical/technical complications and failures, occlusal analysis, presence/absence of attrition, and location, extension, and retention type. Results Out of three hundred ninety seven fixed reconstructions in three hundred three patients, two hundred sixty eight were SCs and one hundred twenty seven were FDPs. Of these three hundred ninety seven implant-supported reconstructions, 18 had failed, yielding a failure rate of 4.5% and a survival rate of 95.5% after a mean observation period of 10.75 years (range: 8.4-13.5 years). The most frequent complication was ceramic chipping (20.31%) followed by occlusal screw loosening (2.57%) and loss of retention (2.06%). No occlusal screw fracture, one abutment loosening, and two abutment fractures were noted. This resulted in a total mechanical/technical complication rate of 24.7%. The prosthetic success rate over a mean follow-up time of 10.75 years was 70.8%. Generalized attrition and FDPs were associated with statistically significantly higher rates of ceramic fractures when compared with SCs. Cantilever extensions, screw retention, anterior versus posterior, and gender did not influence the chipping rate. Conclusions After a mean exposure time of 10.75 years, high survival rates for reconstructions supported by Sand-blasted Large-grit Acid-etched implants can be expected. Ceramic chipping was the most frequent complication and was increased in dentitions with attrition and in FDPs compared with SCs.
引用
收藏
页码:356 / 364
页数:9
相关论文
共 22 条
[1]   A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years [J].
Aglietta, Marco ;
Siciliano, Vincenzo Iorio ;
Zwahlen, Marcel ;
Braegger, Urs ;
Pjetursson, Biarni E. ;
Lang, Niklaus P. ;
Salvi, Giovanni E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) :441-451
[2]  
Belser UC, 2009, J PERIODONTOL, V80, P140, DOI [10.1902/jop.2009.080435, 10.1902/jop.2009.080435 ]
[3]   Early Loading at 21 Days of Non-Submerged Titanium Implants With a Chemically Modified Sandblasted and Acid-Etched Surface: 3-Year Results of a Prospective Study in the Posterior Mandible [J].
Bornstein, Michael M. ;
Wittneben, Julia-Gabriela ;
Bragger, Urs ;
Buser, Daniel .
JOURNAL OF PERIODONTOLOGY, 2010, 81 (06) :809-818
[4]   Early loading of non-submerged titanium implants with a sandblasted and acid-etched surface [J].
Bornstein, MM ;
Schmid, B ;
Belser, UC ;
Lussi, A ;
Buser, D .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (06) :631-638
[5]   Complication and failure rates of fixed dental prostheses in patients treated for periodontal disease [J].
Braegger, Urs ;
Hirt-Steiner, Stefanie ;
Schnell, Natascha ;
Schmidlin, Kurt ;
Salvi, Giovanni E. ;
Pjetursson, Bjarni ;
Matuliene, Giedre ;
Zwahlen, Marcel ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (01) :70-77
[6]   10-Year Survival and Success Rates of 511 Titanium Implants with a Sandblasted and Acid-Etched Surface: A Retrospective Study in 303 Partially Edentulous Patients [J].
Buser, Daniel ;
Janner, Simone F. M. ;
Wittneben, Julia-Gabriela ;
Braegger, Urs ;
Ramseier, Christoph A. ;
Salvi, Giovanni E. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :839-851
[7]   Stability of Contour Augmentation and Esthetic Outcomes of Implant-Supported Single Crowns in the Esthetic Zone: 3-Year Results of a Prospective Study With Early Implant Placement Postextraction [J].
Buser, Daniel ;
Wittneben, Julia ;
Bornstein, Michael M. ;
Gruetter, Linda ;
Chappuis, Vivianne ;
Belser, Urs C. .
JOURNAL OF PERIODONTOLOGY, 2011, 82 (03) :342-349
[8]  
Gallucci GO, 2009, INT J ORAL MAX IMPL, V24, P132
[9]   Clinical complications with implants and implant prostheses [J].
Goodacre, CJ ;
Bernal, G ;
Rungcharassaeng, K ;
Kan, JYK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) :121-132
[10]   A systematic review of the 5-year survival and complication rates of implant-supported single crowns [J].
Jung, Ronald E. ;
Pjetursson, Bjarni E. ;
Glauser, Roland ;
Zembic, Anja ;
Zwahlen, Marcel ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (02) :119-130