Endovascular Repair of Traumatic Thoracic Aortic Injury: Final Results From the Relay Endovascular Registry for Thoracic Disease

被引:36
作者
Zipfel, Burkhart [1 ]
Chiesa, Roberto
Kahlberg, Andrea
Marone, Enrico Maria
Rousseau, Herve
Kaskarelis, Ioannis
Riambau, Vincent
Coppi, Gioacchino
Ferro, Carlo
Sassi, Carlo
Esteban, Carlos
Mangialardi, Nicola
Tealdi, Domenico G.
Nano, Giovanni
Schoder, Maria
Funovics, Martin
Buz, Semih
Hetzer, Roland
机构
[1] Deutsch Herzzentrum Berlin, Dept Cardiothorac & Vasc Surg, D-13353 Berlin, Germany
关键词
LEFT SUBCLAVIAN ARTERY; STENT-GRAFT; PRACTICE GUIDELINES; ENDOGRAFT COLLAPSE; SURGICAL REPAIR; RUPTURE; TRANSECTION; MULTICENTER; EXPERIENCE; MANAGEMENT;
D O I
10.1016/j.athoracsur.2013.09.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In blunt thoracic aortic injury, thoracic endovascular aortic repair (TEVAR) offers a less invasive alternative to open chest surgery. New reliable and accurate stent grafts have widened the endovascular treatment options. We report our experience with the Relay stent graft Bolton Medical, Sunrise, FL; Barcelona, Spain) for treatment of this injury. Methods. Relay Endovascular Registry for Thoracic Disease (RESTORE) is a multicenter, prospective European registry, which enrolled patients treated with the Relay stent graft for thoracic aortic diseases from April 2005 to January 2009. Regular follow-up examinations were conducted for up to 24 months. This paper analyzes the cohort of patients treated for traumatic aortic injury. Results. Forty adult trauma patients from 12 European centers underwent TEVAR. Mean age was 40 years and 34 patients were male. The proximal landing zone involved aortic arch zones 1 to 2 in 40% and zone 3 in 55% of procedures. Technical success was achieved in all cases. One (2.5%) patient suffered a rupture of the iliac artery. No patient developed procedure-related paraplegia or required conversion to open surgery. Followup imaging demonstrated complete exclusion of the traumatic tear and regression of the false aneurysms without endoleak or graft infolding. One late device-related complication was reported; penetration of the distal end of the stent graft treated by stent-graft extension. Thirty-day mortality was 2.5 % (n = 1), and late mortality 2.5% due to a secondary accident. Actuarial 2-year survival was 93.7%. Conclusions. Thoracic endovascular aortic repair with the Relay stent graft is a safe and effective treatment for patients with traumatic aortic injury. (C) 2014 by The Society of Thoracic Surgeons
引用
收藏
页码:774 / 781
页数:8
相关论文
共 28 条
[1]   Fatal blunt aortic injuries: A review of 242 autopsy cases [J].
Burkhart, HM ;
Gomez, GA ;
Jacobson, LE ;
Pless, JE ;
Broadie, TA .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (01) :113-115
[2]   Conventional surgical repair and endovascular treatment of acute traumatic aortic rupture [J].
Buz, Semih ;
Zipfel, Burkhart ;
Mulahasanovic, Sead ;
Pasic, Miralem ;
Weng, Yuguo ;
Hetzer, Roland .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (02) :143-149
[3]   Technical strategies to expand stent-graft applicability in the aortic arch and proximal descending thoracic aorta [J].
Criado, FJ ;
Barnatan, MF ;
Rizk, Y ;
Clark, NS ;
Wang, CF .
JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 :32-38
[4]   Diagnosis and treatment of blunt thoracic aortic injuries: Changing perspectives [J].
Demetriades, Demetrios ;
Velmahos, George C. ;
Scalea, Thomas M. ;
Jurkovich, Gregory J. ;
Karmy-Jones, Riyad ;
Teixeira, Pedro G. ;
Hemmila, Mark R. ;
O'Connor, James V. ;
McKenney, Mark O. ;
Moore, Forrest O. ;
London, Jason ;
Singh, Michael J. ;
Spaniolas, Konstantinos ;
Keel, Marius ;
Sugrue, Michael ;
Wahl, Wendy L. ;
Hill, Jonathan ;
Wall, Mathew J. ;
Moore, Ernest E. ;
Lineen, Edward ;
Margulies, Daniel ;
Malka, Valerie ;
Chan, Linda S. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (06) :1415-1418
[5]   Operative repair or endovascular stent graft in blunt traumatic thoracic aortic injuries: Results of an American Association for the Surgery of Trauma multicenter study [J].
Demetriades, Demetrios ;
Velmahos, George C. ;
Scalea, Thomas M. ;
Jurkovich, Gregory J. ;
Karmy-Jones, Riyad ;
Teixeira, Pedro G. ;
Hemmila, Mark R. ;
O'Connor, James V. ;
McKenney, Mark O. ;
Moore, Forrest O. ;
London, Jason ;
Singh, Michael J. ;
Lineen, Edward ;
Spaniolas, Konstantinos ;
Keel, Marius ;
Sugrue, Michael ;
Wahl, Wendy L. ;
Hill, Jonathan ;
Wall, Mathew J. ;
Moore, Ernest E. ;
Margulies, Daniel ;
Malka, Valerie ;
Chan, Linda S. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (03) :561-570
[6]  
Fabian TC, 2009, AM SURGEON, V75, P273
[7]   Endovascular Repair of the Descending Aorta and the Aortic Arch With the Relay Stent Graft [J].
Funovics, Martin ;
Blum, Melanie ;
Langenberger, Herbert ;
Plank, Christina ;
Schoder, Maria ;
Edelhauser, Gundula ;
Gottardi, Roman ;
Berzacky, Dominik ;
Dorfmeister, Marion ;
Grimm, Michael ;
Lammer, Johannes ;
Czerny, Martin .
ANNALS OF THORACIC SURGERY, 2009, 88 (02) :637-640
[8]   Endovascular stent-graft or open surgical repair for blunt thoracic aortic trauma: Systematic review [J].
Hoffer, Eric K. ;
Forauer, Andrew R. ;
Silas, Anne M. ;
Gemery, John M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (08) :1153-1164
[9]   Thoracic aorta injuries: Management and outcome of 144 patients [J].
Hunt, JP ;
Baker, CC ;
Lentz, CW ;
Rutledge, RR ;
Oller, DW ;
Flowe, KM ;
Nayduch, DA ;
Smith, C ;
Clancy, TV ;
Thomason, MH ;
Meredith, JW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (04) :547-556
[10]   Collapse of a stent-graft following treatment of a traumatic thoracic aortic rupture [J].
Idu, MM ;
Reekers, JA ;
Balm, R ;
Ponsen, KJ ;
de Mol, BAJM ;
Legemate, DA .
JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (04) :503-507