Efficient and Robust Detection of Local Impedance Changes Using Selected Electrical Excitation Conditions

被引:2
作者
Yoshimoto, Shunsuke [1 ]
Ikemoto, Naoki [2 ]
Ishizuka, Hiroki [2 ]
Ikeda, Sei [2 ]
Kuroda, Yoshihiro [3 ]
Oshiro, Osamu [2 ]
机构
[1] Univ Tokyo, Grad Sch Frontier Sci, Kashiwa, Chiba 2778563, Japan
[2] Osaka Univ, Grad Sch Engn Sci, Toyonaka, Osaka 5608531, Japan
[3] Univ Tsukuba, Fac Engn Informat & Syst, Tsukuba, Ibaraki 3058577, Japan
基金
日本学术振兴会;
关键词
Electrical impedance; compressed sensing; potential distribution; muscle injury; MUSCLE INJURY; TOMOGRAPHY; HEALTHY; BRAIN;
D O I
10.1109/ACCESS.2020.3037167
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Bioelectrical impedance method is useful for evaluating tissue state such as muscle injury but there is a trade off between efficiency and robustness in detection of various local impedance changes. To solve this problem, we proposed a method using compressed electrical impedance sensing and discrimination analysis. We employed multiple excitation conditions like electrical impedance tomography, and investigated the effective excitation conditions. We then used both simulation and measurement data for efficient training process. In our experiment, we implemented a simulator and a measurement system with 16 electrodes and biological phantoms, and evaluated the discrimination rate for various impedance distribution by assuming muscle injury. As a result, we found that 6/120 excitation conditions are sufficient for detection of local impedance changes in a simple model and sufficient blending ratio of the measurement data to simulation data was 10.6% to perform 90% discrimination. The experimental result also indicated that the proposed method was robust for injury size, injury position, and body shape and 90% discrimination was achieved using 13/120 excitation conditions for complex models including skin, bone, and muscle area.
引用
收藏
页码:205778 / 205787
页数:10
相关论文
共 43 条
[1]   Electrical Impedance Tomography: Tissue Properties to Image Measures [J].
Adler, Andy ;
Boyle, Alistair .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (11) :2494-2504
[2]  
[Anonymous], 2018, 604791 IEC TS
[3]  
[Anonymous], 2006, Wiley Encyclopedia of Biomedical Engineering
[4]   The detection of pleural effusion using a parametric EIT technique [J].
Arad, M. ;
Zlochiver, S. ;
Davidson, T. ;
Shoenfeld, Y. ;
Adunsky, A. ;
Abboud, S. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (04) :421-428
[5]   A survey of cross-validation procedures for model selection [J].
Arlot, Sylvain ;
Celisse, Alain .
STATISTICS SURVEYS, 2010, 4 :40-79
[6]   Creatine-Kinase- and Exercise-Related Muscle Damage Implications for Muscle Performance and Recovery [J].
Baird, Marianne F. ;
Graham, ScottM. ;
Baker, Julien S. ;
Bickerstaff, Gordon F. .
JOURNAL OF NUTRITION AND METABOLISM, 2012, 2012
[7]   Partial least squares for discrimination [J].
Barker, M ;
Rayens, W .
JOURNAL OF CHEMOMETRICS, 2003, 17 (03) :166-173
[8]   Creatine kinase monitoring in sport medicine [J].
Brancaccio, Paola ;
Maffulli, Nicola ;
Limongelli, Francesco Mario .
BRITISH MEDICAL BULLETIN, 2007, 81-82 :209-230
[9]   Bioimpedance technology for detection of thoracic injury [J].
Buendia, Ruben ;
Candefjord, Stefan ;
Sanchez, Benjamin ;
Granhed, Hans ;
Sjoqvist, Bengt-Arne ;
Ortenwall, Per ;
Caragounis, Eva-Corina .
PHYSIOLOGICAL MEASUREMENT, 2017, 38 (11) :2000-2014
[10]   ELECTRONIC AGGREGOMETER - NOVEL DEVICE FOR ASSESSING PLATELET BEHAVIOR IN BLOOD [J].
CARDINAL, DC ;
FLOWER, RJ .
JOURNAL OF PHARMACOLOGICAL METHODS, 1980, 3 (02) :135-158