Depth of sternal compression and intra-arterial blood pressure during CPR in infants following cardiac surgery

被引:37
|
作者
Maher, Kevin O. [1 ]
Berg, Robert A. [2 ]
Lindsey, C. Wesley [1 ]
Simsic, Janet [1 ]
Mahle, William T. [1 ]
机构
[1] Emory Univ, Sch Med, Sibley Heart Ctr Cardiol, Atlanta, GA 30341 USA
[2] Childrens Hosp Philadelphia, Dept Anesthesiol & Crit Care Med, Philadelphia, PA 19104 USA
关键词
Child; Infant; CPR; Blood pressure; CHEST COMPRESSION; CARBON-DIOXIDE; ARREST;
D O I
10.1016/j.resuscitation.2009.03.016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The optimal depth of sternal compressions during cardiopulmonary resuscitation (CPR) in infants is unknown; current guidelines recommend compressing to a depth of 1/3rd to 1/2 the anterior-posterior (AP) diameter of the chest. Our experience to compress the chest at 1/3rd the AP diameter often fails to provide an adequate blood pressure response. We reviewed our experience with CPR, depth of compressions, and arterial blood pressure response in a cohort of 6 infants having cardiac surgery and subsequent cardiac arrest. Pediatric advanced life support measures were initiated, with attempted compressions to 1/3rd the AP chest diameter. Depth of attempted compressions was increased to approximately 1/2 the AP chest diameter if systolic BP response was inadequate (i.e., <60 mm Hg systolic). BP tracings were reviewed and Contiguous recordings were evaluated as compressions were attempted at 1/3rd and 1/2 the AP chest diameter. The age range was from 2 weeks to 7.3 months, and median age was of 1.0 month. The mean systolic BP was 83.4 mm Hg for the 1/2 AP chest diameter technique vs. 51.6 mm Hg for the 1/3rd AP diameter approach, p < 0.001. The mean diastolic pressure was similar with both strategies (30.5 vs. 30.6 mm Hg, p = 0.99). In this cohort of 6 infants having cardiac surgery and subsequent cardiac arrest, attempting to compress the chest at 1/2 the AP diameter increased systolic blood pressure by 62% compared to attempting to compress 1/3rd the AP diameter. Perhaps resuscitators should attempt to compress infants' chests 1/2 rather than 1/3rd the AP diameter of the chest. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:662 / 664
页数:3
相关论文
共 50 条
  • [1] Comparing Intra-Arterial, Auscultatory, and Oscillometric Measurement Methods for Arterial Blood Pressure
    Babadag, Keziban
    Zaybak, Ayten
    FLORENCE NIGHTINGALE JOURNAL OF NURSING, 2021, 29 (02): : 194 - 202
  • [2] Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
    Hofhuizen, C. M.
    Lemson, J.
    Hemelaar, A. E. A.
    Settels, J. J.
    Schraa, O.
    Singh, S. K.
    van der Hoeven, J. G.
    Scheffer, G. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (04) : 493 - 500
  • [3] The agreement between oscillometric and intra-arterial technique for blood pressure monitoring in the lower extremities for infants and toddlers undergoing aortic coarctation repair
    Peng, Zhe-Zhe
    Zhang, Ma-Zhong
    Sun, Ying
    Bai, Jie
    Gu, Hong-Bin
    Liu, Pei-Pei
    Li, Min
    Cai, Mei-Hua
    PEDIATRIC ANESTHESIA, 2016, 26 (11) : 1091 - 1096
  • [4] The influence of nonlinear intra-thoracic vascular behaviour and compression characteristics on cardiac output during CPR
    Koeken, Yvette
    Aelen, Paul
    Noordergraaf, Gerrit J.
    Paulussen, Igor
    Woerlee, Pierre
    Noordergraaf, Abraham
    RESUSCITATION, 2011, 82 (05) : 538 - 544
  • [5] Evaluation of the oscillometric method for noninvasive blood pressure measurement during cuff deflation and cuff inflation with reference to intra-arterial blood pressure
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Argha, Ahmadreza
    Rehan, Rajan
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42 (07) : 1235 - 1247
  • [6] Sternal wall pressure comparable to leaning during CPR impacts intrathoracic pressure and haemodynamics in anaesthetized children during cardiac catheterization
    Glatz, Andrew C.
    Nishisaki, Akira
    Niles, Dana E.
    Hanna, Brian D.
    Eilevstjonn, Joar
    Diaz, Laura K.
    Gillespie, Matthew J.
    Rome, Jonathan J.
    Sutton, Robert M.
    Berg, Robert A.
    Nadkarni, Vinay M.
    RESUSCITATION, 2013, 84 (12) : 1674 - 1679
  • [7] Association of arterial blood pressure and CPR quality in a child using three different compression techniques, a case report
    Sainio, Marko
    Sutton, Robert M.
    Huhtala, Heini
    Eilevstjonn, Joar
    Tenhunen, Jyrki
    Olkkola, Klaus T.
    Nadkarni, Vinay M.
    Hoppu, Sanna
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2013, 21
  • [8] Association of arterial blood pressure and CPR quality in a child using three different compression techniques, a case report
    Marko Sainio
    Robert M Sutton
    Heini Huhtala
    Joar Eilevstjønn
    Jyrki Tenhunen
    Klaus T Olkkola
    Vinay M Nadkarni
    Sanna Hoppu
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 21
  • [9] A Comparison of Non-Invasive Blood Pressure Measurement Strategies with Intra-Arterial Measurement
    Rebesco, Matthew R.
    Pinkston, M. Cornelia
    Smyrnios, Nicholas A.
    Weisberg, Stacy N.
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (05) : 516 - 523
  • [10] Intra-arterial blood pressure reading in intensive care unit patients in the lateral position
    Aries, Marcel J. H.
    Aslan, Adnan
    Elting, Jan Willem J.
    Stewart, Roy E.
    Zijlstra, Jan G.
    De Keyser, Jacques
    Vroomen, Patrick C. A. J.
    JOURNAL OF CLINICAL NURSING, 2012, 21 (13-14) : 1825 - 1830